Negative electrospray ionization ion mobility spectrometry combined with paper-based molecular imprinted polymer disks: A novel approach for rapid target screening of trace organic compounds in water samples

A novel approach for the rapid target screening of water contaminants in trace concentrations was applied for the determination of the artificial sweetener Acesulfame-K, an accepted municipal wastewater indicator. This new method combines the selective enrichment of target analytes on paper-based mo...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) Vol. 190; pp. 47 - 54
Main Authors: Zarejousheghani, Mashaalah, Schrader, Steffi, Möder, Monika, Mayer, Thomas, Borsdorf, Helko
Format: Journal Article
Language:English
Published: Netherlands Elsevier B.V 01-12-2018
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A novel approach for the rapid target screening of water contaminants in trace concentrations was applied for the determination of the artificial sweetener Acesulfame-K, an accepted municipal wastewater indicator. This new method combines the selective enrichment of target analytes on paper-based molecular imprinted polymer disks and the subsequent analysis using a modified ion mobility spectrometer allowing negative electrospray ionization (ESI-IMS). Our developed ion mobility spectrometer permits the sensitive detection of Acesulfame with a limit of detection of 93 µg L−1 within few seconds without sample separation. The use of modified paper filters for fast extraction and enrichment of the target substance from water samples results in a lower limit of detection of 0.19 µg L−1. This procedure is directly applicable in the field, the transport and the proper storage of bulky sample bottles is avoided. The capability of the procedure developed was demonstrated by measuring real samples from a river at locations upstream and downstream of the effluent of the central municipal waste water treatment plant. The quantitative data of ion mobility measurements show a very good agreement with those obtained with the commonly used standard procedure (high performance liquid chromatography-tandem mass spectrometry). [Display omitted] •A simple on-site procedure for trace organic compounds in water samples was developed.•Paper-based molecular imprinted polymer disks are highly specific sampling tools.•Electrospray ionization was successfully coupled to Ion mobility spectrometry.•0.19 µg L−1 of Acesulfame can be determined in water samples.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2018.07.076