Fully automated method for quantitative determination of steroids in serum: An approach to evaluate steroidogenesis
Steroidogenesis is a set of metabolic reactions where the enzymes play a key role to control the physiological levels of steroids. A deficiency in steroidogenesis induces an accumulation and/or insufficiency of steroids in human blood and can lead to different pathologies. This issue added to the lo...
Saved in:
Published in: | Talanta (Oxford) Vol. 224; p. 121923 |
---|---|
Main Authors: | , |
Format: | Journal Article |
Language: | English |
Published: |
Netherlands
Elsevier B.V
01-03-2021
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Steroidogenesis is a set of metabolic reactions where the enzymes play a key role to control the physiological levels of steroids. A deficiency in steroidogenesis induces an accumulation and/or insufficiency of steroids in human blood and can lead to different pathologies. This issue added to the low levels of steroids (pg mL−1 to ng mL−1) in this biofluid make of their determination an analytical challenge. In this research, we present a high-throughtput and fully automated method based on solid-phase extraction on-line coupled to liquid chromatography with tandem mass spectrometry detection (SPE–LC–MS/MS) to quantify estrogens (estrone and estradiol), androgens (testosterone, androstenedione, dihydrotestosterone and dehydroepiandrosterone), progestogens (progesterone, pregnenolone, 17-hydroxyprogesterone and 17-hydroxypregnenolone), glucocorticoids (21-hydroxyprogesterone, 11-deoxycortisol, cortisone, corticosterone and cortisol) and one mineralocorticoid (aldosterone) in human serum. The performance of the SPE step and the multiple reaction monitoring (MRM) mode allowed reaching a high sensitivity and selectivity levels without any derivatization reaction. The fragmentation mechanisms of the steroids were complementary studied by LC–MS/MS in high-resolution mode to confirm the MRM transitions. The method was characterized with two SPE sorbents with similar physico-chemical properties. Thus, limits of quantification were at pg mL−1 levels, the variability was below 25% (except for pregnenolone and cortisone), and the accuracy, expressed as bias, was always within ±25%. The proposed method was tested in human serum from ten volunteers, who reported levels for the sixteen target steroids that were satisfactorily in agreement with the physiological ranges reported in the literature.
[Display omitted]
•A fully automated method is proposed for analysis of 16 steroids in human serum.•Shortening of the analysis time due to the sample preparation protocol.•Quantitation limits at pg mL−1 without derivatization reactions.•Complete study fragmentation mechanisms.•Characterization of the method with two SPE sorbents. |
---|---|