Recalibration of the Soft X-Ray Telescope Onboard Yohkoh

We present a new derivation of the X-ray spectral sensitivity of the Soft X-ray Telescope (SXT) experiment onboard Yohkoh . The recalibration is based upon the hypothesis that, during the first 15 months of the mission, an absorbing material gradually built up on the entrance filters of the telescop...

Full description

Saved in:
Bibliographic Details
Published in:Solar physics Vol. 293; no. 10; pp. 1 - 8
Main Author: Acton, Loren W.
Format: Journal Article
Language:English
Published: Dordrecht Springer Netherlands 01-10-2018
Springer Nature B.V
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We present a new derivation of the X-ray spectral sensitivity of the Soft X-ray Telescope (SXT) experiment onboard Yohkoh . The recalibration is based upon the hypothesis that, during the first 15 months of the mission, an absorbing material gradually built up on the entrance filters of the telescope. We have also re-evaluated the times and sizes of ruptures of the SXT entrance filters. The impact of this recalibration on derived filter-ratio temperature, emission measure, and calculated spectral irradiance is substantial, especially for SXT data prior to November 1992.
ISSN:0038-0938
1573-093X