Application of Sonographic BI-RADS to Synchronous Breast Nodules Detected in Patients with Breast Cancer
The purpose of this study was to evaluate the applicability of the current BI-RADS for sonography to the assessment of synchronous breast nodules other than the primary malignant tumor in patients with breast cancer. One hundred eighty-nine synchronous nodules in 147 breast cancer patients were surg...
Saved in:
Published in: | American journal of roentgenology (1976) Vol. 191; no. 3; pp. 653 - 658 |
---|---|
Main Authors: | , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Leesburg, VA
Am Roentgen Ray Soc
01-09-2008
American Roentgen Ray Society |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The purpose of this study was to evaluate the applicability of the current BI-RADS for sonography to the assessment of synchronous breast nodules other than the primary malignant tumor in patients with breast cancer.
One hundred eighty-nine synchronous nodules in 147 breast cancer patients were surgically excised after localization, and 412 synchronous nodules in 191 patients were observed or biopsied or excised without localization. Among a total of 601 synchronous nodules, 372 nodules were ipsilateral and 229 were contralateral to a primary malignant tumor. Two radiologists retrospectively reviewed sonograms of these nodules and determined the sonographic BI-RADS category without clinical information or pathologic results. For each nodule, the preoperative BI-RADS category and pathologic or follow-up results were compared.
Four hundred eighty-two nodules were classified category 3; 112 nodules, category 4; and seven nodules, category 5. Fifty-five (11.4%) of the category 3 nodules and 57 (47.9%) of the category 4 and 5 nodules were confirmed malignant. Thirty-six (21.2%) of 170 category 3 synchronous nodules in the same quadrant as the primary tumor were confirmed malignant, as were 12 (9.8%) of 122 nodules in a different quadrant and eight (4.2%) of 190 nodules in the contralateral breast.
For assessment of synchronous nodules in breast cancer patients, application of conventional screening sonographic BI-RADS categories may not account for possible increased risk of malignancy in synchronous nodules, especially those in the same quadrant of the breast as the index malignant tumor. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0361-803X 1546-3141 |
DOI: | 10.2214/AJR.07.2861 |