A new technique to avoid the intraoperative complications of septal myectomy in patients with obstructive hypertrophic cardiomyopathy
Although transaortic septal myectomy in obstructive hypertrophic cardiomyopathy (OHC) is accepted as a safe procedure, it may end up with serious peroperative complications. We developed a practical method to avoid this unfavorable outcome by using a 20-cc syringe body. We believe this apparatus wil...
Saved in:
Published in: | Heart and vessels Vol. 24; no. 1; pp. 70 - 72 |
---|---|
Main Authors: | , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Japan
Springer Japan
2009
Springer Nature B.V |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Although transaortic septal myectomy in obstructive hypertrophic cardiomyopathy (OHC) is accepted as a safe procedure, it may end up with serious peroperative complications. We developed a practical method to avoid this unfavorable outcome by using a 20-cc syringe body. We believe this apparatus will provide safe and effective septal myectomy procedures without additional cost. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0910-8327 1615-2573 |
DOI: | 10.1007/s00380-008-1081-6 |