A novel biosensing system for rapid and sensitive detection of heavy metal toxicity in water

Toxicity biosensors have recently gained significant attention due to their potential use in online monitoring. However, the effects of toxicants and the influence of dose, exposure time, and type and concentration of respiration substrate (RS) on the performance of a bioreactor are species-specific...

Full description

Saved in:
Bibliographic Details
Published in:Journal of hazardous materials Vol. 416; p. 126123
Main Authors: Ngoc, Le Thi Bao, Linh, Duong Nhat, Van Minh, Nguyen, Duy, Nguyen Phuc Hoang, Phuong, Pham Thi Thuy
Format: Journal Article
Language:English
Published: Elsevier B.V 15-08-2021
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Toxicity biosensors have recently gained significant attention due to their potential use in online monitoring. However, the effects of toxicants and the influence of dose, exposure time, and type and concentration of respiration substrate (RS) on the performance of a bioreactor are species-specific. Although these factors need to be investigated case-by-case as they can lead either to damage or self-repair of the affected microorganisms, they have seldom been considered in previous studies. Therefore, this work examined, for the first time, the effects of resting time and RS concentration on the performance of the biosensing system for toxicity of Cr6+ in water. In addition, it is also the first time that a novel non-contact fluid delivery system was applied to a toxicity biosensing system to prevent unstable responses. By choosing the best RS concentration and balancing the resting and exposure times, the proposed procedure exhibits promising results in terms of minimum detectable concentration (MDC), limit of detection (LOD), detection range, linearity, sensitivity, reproducibility and accuracy. The recovery time was only a few hours and the coefficients of variation of inhibition and recovery were only 12% and 9.6%, respectively, during six times reuse over one month of storage. [Display omitted] •A novel method for rapid and accurate measurement of Cr6+ toxicity was developed.•It uses a low-cost and reusable packed bed bioreactor that can be prepared onsite.•The response time is only 1 h for detection of 10 mg/L Cr6+ without incubation•Better reproducibility was obtained due to employing a non-contact fluid delivery.•The assay shows good accuracy which is up to 97% in determining Cr6+ concentration.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0304-3894
1873-3336
DOI:10.1016/j.jhazmat.2021.126123