A novel source side power quality improved soft starting of three-phase induction motor using a symmetrical angle controller through pic microcontroller

PIC microcontroller has a vital role in various types of controllers and nowadays the presence of PIC microcontroller is unavoidable in most control applications. This paper describes the enhancement of soft starting of induction motors using PIC microcontroller. Soft starting is required for the in...

Full description

Saved in:
Bibliographic Details
Published in:Bulletin of the Polish Academy of Sciences. Technical sciences Vol. 69; no. 2; p. 136746
Main Authors: Selvaperumal, S., Krishnamoorthy, N., Prabhakar, G.
Format: Journal Article
Language:English
Published: Warsaw Polish Academy of Sciences 01-04-2021
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:PIC microcontroller has a vital role in various types of controllers and nowadays the presence of PIC microcontroller is unavoidable in most control applications. This paper describes the enhancement of soft starting of induction motors using PIC microcontroller. Soft starting is required for the induction motors with reduced applied voltages so that the peak starting current is reduced and the startup of the motor is smooth with controlled torque and reduced mechanical vibrations, reduced starting current with correspondingly reduced bus voltage drops. While many of the available schemes of soft starting offer better results in view of smooth starting process, the proposed methodology offers soft starting as well as it cares about the source current quality. In contrast to the conventional multistep starting scheme, in this work a continuously controlled starting scheme is proposed. The three phase AC voltage controller topology is used as the core controller. In each of the half cycles, instead of a single conduction period with a single delay angle, the proposed AC voltage controller is switched symmetrically in each half cycle with multiple pulses in each quarter cycle. Symmetrically placed fixed numbers of switching pulses are used. The paper also describes the various time ratio controls namely the phase angle controller, the extinction angle controller and the symmetrical angle controller. The design aspects of the proposed soft starting scheme and the validation of the proposed system in the MATLAB SIMULINK environment are presented in this paper.
ISSN:2300-1917
0239-7528
2300-1917
DOI:10.24425/bpasts.2021.136746