Failure analysis in the tube of the refrigeration system of a reheating furnace

•Failure analysis of cooling system tube.•Microstructural changes due to loss of the refractory.•Structural steel tube corrosion due to microstructural changes. This work aimed to analyze a failure that occurred prematurely in an ASTM SS Grade 70 steel tube in the cooling system of a reheating furna...

Full description

Saved in:
Bibliographic Details
Published in:Engineering failure analysis Vol. 120; p. 105052
Main Authors: Ávila, E.M.C., Dornellas, M.P., Correa, S.R., Pimenta, A.R., Diniz, M.G.