Development of a very sensitive electrochemical magneto immunosensor for the direct determination of ochratoxin A in red wine

An electrochemical immunosensor (EI) for the determination of ochratoxin A (OTA) in red wine samples was developed. This immunosensor was based on Protein G functionalized magnetic beads (MBs) as solid phase for affinity reaction between OTA and OTA monoclonal antibody (mAbOTA). A carbon screen prin...

Full description

Saved in:
Bibliographic Details
Published in:Sensors and actuators. B, Chemical Vol. 162; no. 1; pp. 327 - 333
Main Authors: Perrotta, Patricio René, Arévalo, Fernando Javier, Vettorazzi, Nelio Roberto, Zón, María Alicia, Fernández, Héctor
Format: Journal Article
Language:English
Published: Elsevier B.V 20-02-2012
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:An electrochemical immunosensor (EI) for the determination of ochratoxin A (OTA) in red wine samples was developed. This immunosensor was based on Protein G functionalized magnetic beads (MBs) as solid phase for affinity reaction between OTA and OTA monoclonal antibody (mAbOTA). A carbon screen printed-electrodes (CSPE) system was used as electrochemical transduction element. This immunosensor was based on a direct competitive assay between OTA in wine samples and OTA labeled with horseradish peroxidase (HRP) (OTA–HRP). The HRP, in the presence of hydrogen peroxide catalyzes the oxidation of pyrocatechol to benzoquinone, whose back electrochemical reduction was detected on a CSPE by square wave voltammetry (SWV). The experimental variables involved in the immunosensor response to OTA were evaluated. The performance obtained for the EI was an analytical range of 0.01–20ppb, limit of detection (LOD) of 0.008ppb, and IC50=0.272±0.081ppb. In addition, an acceptable accuracy with a relative standard deviation (RSD) of 5.56% and very good recoveries (92–110%) were found. This work shows the potential of our EI for the direct measurement of OTA in red wine samples combining SWV as electroanalytical technique with the MBs and CSPE. This EI has great advantages as direct measurement of red wine samples without a prior pretreatment, the small volume of sample, the short time consuming of experiences and LOD well below those established by the Regulatory Commission of the European Community (2μgkg−1).
Bibliography:http://dx.doi.org/10.1016/j.snb.2011.12.089
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2011.12.089