Study of the 16-Channel Scintillation Detector Prototype with Silicon Photomultiplier Readout

In the Laboratory of High-Energy Physics, 16-channel prototypes of detectors (with SiPM readout produced by Ketek and Hamamatsu) were developed for their application in zero-degree calorimetry and for measuring the profile of a low-energy neutron beam. This paper presents the method for determining...

Full description

Saved in:
Bibliographic Details
Published in:Physics of atomic nuclei Vol. 83; no. 12; pp. 1691 - 1694
Main Authors: Tishevskiy, A. V., Gurchin, Yu. V., Isupov, A. Yu, Kurilkin, P. K., Ladygin, V. P., Reznikov, S. G., Skhomenko, Ya. T., Terekhin, A. A., Khrenov, A. N.
Format: Journal Article
Language:English
Published: Moscow Pleiades Publishing 01-12-2020
Springer
Springer Nature B.V
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In the Laboratory of High-Energy Physics, 16-channel prototypes of detectors (with SiPM readout produced by Ketek and Hamamatsu) were developed for their application in zero-degree calorimetry and for measuring the profile of a low-energy neutron beam. This paper presents the method for determining the voltage of the breakpoint of the noise characteristic of silicon photomultipliers in the multichannel detector and its temperature dependence in the range from 27.7°C to 39.1°C. The response of SiPM to the LED source of calibrated light pulses has been studied and the time resolution has been obtained.
ISSN:1063-7788
1562-692X
DOI:10.1134/S1063778820110095