Safe right bundle branch block pattern during permanent right ventricular pacing: a case report
We present the case of a 72-year-old male who underwent a permanent transvenous DDD pacemaker implantation for symptomatic complete heart block. The postoperative surface electrocardiogram (ECG) revealed a right bundle branch block (RBBB) pacing pattern with transition in lead V3 and left bundle bra...
Saved in:
Published in: | Türk Kardiyoloji Derneği arşivi Vol. 41; no. 6; pp. 522 - 525 |
---|---|
Main Authors: | , , |
Format: | Journal Article |
Language: | English |
Published: |
Turkey
KARE Publishing
01-09-2013
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We present the case of a 72-year-old male who underwent a permanent transvenous DDD pacemaker implantation for symptomatic complete heart block. The postoperative surface electrocardiogram (ECG) revealed a right bundle branch block (RBBB) pacing pattern with transition in lead V3 and left bundle branch block (LBBB) in D1, suggesting a malpositioned ventricular lead in the left heart. Malposition of a lead was ruled out by chest X-ray and echocardiogram confirming apical right ventricular pacing. After a literature review, a surface ECG maneuver, by placing leads V1 and V2 one intercostal space lower, restored the usual patterns of paced LBBB pattern. We discuss the literature concerning safe-paced RBBB. |
---|---|
Bibliography: | ObjectType-Case Study-2 SourceType-Scholarly Journals-1 ObjectType-Feature-4 content type line 23 ObjectType-Report-1 ObjectType-Article-3 |
ISSN: | 1016-5169 1016-5169 |
DOI: | 10.5543/tkda.2013.44845 |