Failure of total hip arthroplasty with a precoated prosthesis. 4- to 11-year results

A series of early femoral component failures prompted a detailed retrospective clinical and radiographic review of 176 hybrid cemented total hip arthroplasties using a polymethyl-methacrylate coated femoral prosthesis. All surgeries were performed using third generation cement techniques. Average le...

Full description

Saved in:
Bibliographic Details
Published in:Clinical orthopaedics and related research no. 355; p. 123
Main Authors: Dowd, J E, Cha, C W, Trakru, S, Kim, S Y, Yang, I H, Rubash, H E
Format: Journal Article
Language:English
Published: United States 01-10-1998
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A series of early femoral component failures prompted a detailed retrospective clinical and radiographic review of 176 hybrid cemented total hip arthroplasties using a polymethyl-methacrylate coated femoral prosthesis. All surgeries were performed using third generation cement techniques. Average length of followup was 6.3 years (range, 3-12 years). Twenty-one patients died, and one underwent revision surgery because of sepsis. Of the remaining 154 total hip arthroplasties, 23 (15%) of the femoral components failed (21 revised, two definitely loose). The average time to revision was 3.9 years. None of the acetabular components failed. Comparison between the failure and nonfailure groups revealed that poor cement mantles (Grades C or D) with distal cement mantle deficiencies were statistically significant predictors of femoral failure. The most common mechanism of failure was progressive, circumferential cement-bone interface osteolysis with relative preservation of the cement-metal interface. Debonding of the cement column from the prosthesis was a late finding and occurred in only 45% of failed cases. Incorporating the techniques of centralization and centrifugation significantly improved clinical results. Strengthening of the cement-prosthesis interface may magnify the deleterious effects of a poor cement mantle and predisposes the cement-bone interface to failure.
ISSN:0009-921X