Fine needle biopsy without syringe aspiration

Aspiration biopsies of fresh disease-free bovine hepatic liver were performed with three commercially available, small-gauge biopsy needles. A syringe was used to create a negative pressure when using Chiba and Sure-cut needles. A syringe was not used when using PercuCut needles which create an inte...

Full description

Saved in:
Bibliographic Details
Published in:Cardiovascular and interventional radiology Vol. 16; no. 1; pp. 11 - 13
Main Authors: MONSEIN, L. H, KELSEY, C. A, WILLIAMS, W. L, OLSON, N. J
Format: Journal Article
Language:English
Published: Heidelberg Springer 1993
Berlin
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Aspiration biopsies of fresh disease-free bovine hepatic liver were performed with three commercially available, small-gauge biopsy needles. A syringe was used to create a negative pressure when using Chiba and Sure-cut needles. A syringe was not used when using PercuCut needles which create an internal negative pressure equivalent to a 1.5 ml syringe when the stylet is partially withdrawn. The PercuCut and Chiba needle yielded a significantly larger specimen size than the Sure-Cut needle. There was no significant difference in sample size between the PercuCut and Chiba needles. All samples were of diagnostic quality.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0174-1551
1432-086X
DOI:10.1007/BF02603030