CorneaJ: An ImageJ Plugin for Semi-Automated Measurement of Corneal Endothelial Cell Viability
PURPOSE:A reliable experimental measurement of endothelial cell (EC) viability is paramount in the assessment of new drugs, devices, and surgical processes liable to damage the corneal endothelium, as well as during endothelial bioengineering. We previously used triple Hoechst–Ethidium–Calcein-AM la...
Saved in:
Published in: | Cornea Vol. 33; no. 6; pp. 604 - 609 |
---|---|
Main Authors: | , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
United States
by Lippincott Williams & Wilkins
01-06-2014
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | PURPOSE:A reliable experimental measurement of endothelial cell (EC) viability is paramount in the assessment of new drugs, devices, and surgical processes liable to damage the corneal endothelium, as well as during endothelial bioengineering. We previously used triple Hoechst–Ethidium–Calcein-AM labeling coupled with image analysis to determine the viability and mortality of ECs on the whole cornea, thus defining the new notion of viable EC density. To make it accessible to all, and for improved reproducibility, we have now developed an ImageJ plugin with improved thresholding algorithms.
METHODS:The CorneaJ plugin comprised contrast improvement, regional selection of pixels with similar gray levels, simplified thresholding facilitated by a user-friendly images display, and the option of manual touch-up to increase accuracy. After Hoechst–Ethidium–Calcein-AM labeling, the endothelium of 10 human corneas was observed with a fluorescent microscope with motorized stage. The performance of CorneaJ was compared with standard manual thresholdingaccuracy was determined by comparison with fully manual selection of viable ECs by an expert; and reproducibility, by calculating the intraclass coefficient and coefficient of variation (100 × SD/mean) of 7 independent observers.
RESULTS:CorneaJ was more accurate than the standard thresholding, with a deviation from the expected value of −1.8% [95% confidence interval (CI), −2.7 to −0.9] versus 6.0% (95% CI, 2.8–9.3), respectively, P < 0.001. It was also more reproducible, with an intraclass coefficient of 0.98 (95% CI, 0.954–0.994) versus 0.81 (95% CI, 0.628–0.937) and a mean coefficient of variation of 2.6 (1.4–7.4) and 5.7 (3.4–19.8), P = 0.005.
CONCLUSIONS:CorneaJ is a new, fast, and reproducible free image analysis tool that could help standardize experimental measurement of corneal EC viability. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0277-3740 1536-4798 |
DOI: | 10.1097/ICO.0000000000000114 |