The misplaced double J ureteric stent: technique for repositioning using the nitinol 'gooseneck' snare

An antegrade method for repositioning a prematurely released double J ureteric stent is described. The technique is applicable when the proximal pigtail is still within the renal parenchyma or in the perinephric space. A custom-made Nitinol gooseneck snare was used in this case, but suitable alterna...

Full description

Saved in:
Bibliographic Details
Published in:Clinical radiology Vol. 49; no. 5; p. 333
Main Authors: Patel, U, Kellett, M J
Format: Journal Article
Language:English
Published: England 01-05-1994
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:An antegrade method for repositioning a prematurely released double J ureteric stent is described. The technique is applicable when the proximal pigtail is still within the renal parenchyma or in the perinephric space. A custom-made Nitinol gooseneck snare was used in this case, but suitable alternatives should be readily available in a standard interventional suite and these are described.