Automated Noncontact Ultrasound Imaging and Ablation System for the Treatment of Atrial Fibrillation: Outcomes of the First-in-Human VALUE Trial

Catheter ablation for atrial fibrillation (AF) using point-by-point radiofrequency energy or single-application one-shot balloons is either technically challenging or have limited ability to accommodate variable patient anatomy to achieve acute and durable pulmonary vein (PV) isolation. A novel abla...

Full description

Saved in:
Bibliographic Details
Published in:Circulation. Arrhythmia and electrophysiology Vol. 13; no. 3; p. e007917
Main Authors: Turagam, Mohit K., Petru, Jan, Neuzil, Petr, Kakita, Ken, Kralovec, Stepan, Harari, David, Phillips, Patrick, Piazza, Danielo, Whang, William, Dukkipati, Srinivas R., Reddy, Vivek Y.
Format: Journal Article
Language:English
Published: United States American Heart Association, Inc 01-03-2020
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Catheter ablation for atrial fibrillation (AF) using point-by-point radiofrequency energy or single-application one-shot balloons is either technically challenging or have limited ability to accommodate variable patient anatomy to achieve acute and durable pulmonary vein (PV) isolation. A novel ablation system employs low intensity collimated ultrasound (LICU)-guided anatomic mapping and robotic ablation to isolate PVs. In this first-in-human, single-center, multioperator trial, VALUE trial (VytronUS Ablation System for Treatment of Paroxysmal Atrial Fibrillation; NCT03639597) in patients with paroxysmal atrial fibrillation, this LICU system was evaluated to determine its safety, effectiveness in PV isolation, and freedom from recurrent atrial arrhythmias. In the enrolled 52 patients with paroxysmal atrial fibrillation, ultrasound M-mode-based left atrial anatomies were successfully created, and ablation was performed under robotic control along an operator-defined lesion path. The LICU system software advanced over the course of the study: the last 13 patients were ablated with enhanced software. Acute PV isolation was achieved in 98% of PVs-using LICU-only in 77.3% (153/198) of PVs and requiring touch-up with a standard radiofrequency ablation catheter in 22.7% (45/198) PVs. The touch-up rate decreased to 5.8% (3/52) in patients undergoing LICU-ablation with enhanced software. Freedom from atrial arrhythmia recurrence was 79.6% (39/49 patients) at 12 months or 92.3% (12/13 patients) with the enhanced software. Major adverse events occurred in 3 patients (5.8%): one had transient diaphragmatic paralysis, one vascular access complication, and one had transient ST-segment elevation from air-embolism, without sequelae. In this first-in-human study, low- intensity collimated ultrasound-guided anatomic mapping and robotic ablation allows PV isolation with good chronic safety; PV isolation success is improving with device enhancements. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03639597.