Impact of the implementation of the new radiation quantities recommended by ICRU/ICRP for practical use in interventional radiology: a Monte Carlo study

The International Commission on Radiation Units and Measurements (ICRU) proposed a new set of operational quantities for radiation protection for external radiation in its Report Committee 26 ( ). The new proposal aims to improve the coherence between the operational quantities and the definitions o...

Full description

Saved in:
Bibliographic Details
Published in:Journal of radiological protection Vol. 43; no. 1
Main Authors: Abdelrahman, Mahmoud, Lombardo, Pasquale, Dabin, Jérémie, Struelens, Lara, Vanhavere, Filip
Format: Journal Article
Language:English
Published: England 01-03-2023
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The International Commission on Radiation Units and Measurements (ICRU) proposed a new set of operational quantities for radiation protection for external radiation in its Report Committee 26 ( ). The new proposal aims to improve the coherence between the operational quantities and the definitions of the protection quantities in the recommendations of the International Commission on Radiological Protection set out in 2007 ( ). It is expected that this change in operational quantities will impact current dosimeter designs. Although for many photon energies, the conversion coefficients from physical field quantities to the new operational quantities will change relatively little, for radiation fields with low energy photon components, such as medical x-ray applications, there will be a significant decrease in the values of the conversion coefficients. This means that the numerical values of the new operational quantities will be much lower for the same radiation field. These values will be closer to the effective dose, but this change can still cause confusion for medical staff. It is important to examine the effect of the new set of dose conversion coefficients on the personal dose in realistic radiation fields. We performed a study to assess the effect of changing the definition of the operational quantity, personal dose equivalent (Hp), in realistic radiation fields in interventional radiology (IR) workplaces. The x-ray tube kilovoltage peak (kVp) in IR ranges between 60 and 120 kV. The medical staff is exposed to the scattered photons which have a wide range of energies depending on the beam configuration and the patient size. The objective of this study is to 'quantitatively' estimate the impact of implementing the new ICRU quantities of Report 95 in IR radiation fields using Monte Carlo simulations. Simulations of 560 different configurations in IR were performed using MCNPX to calculate fluence binned per energy and angle of incidence.HpandHp(10)were then calculated for each configuration using dose conversion coefficients from fluence given by ICRU Reports 95 and 57, respectively. The results show that the mean of the ratio,Hp(10)/Hp, is 1.6 for all simulated scenarios. This reduction will correct the current overestimation of the effective dose and should result in better compliance with the dose limits in IR. However, it may also have negative consequences on the safety culture among the medical staff. Special care will be needed when interpreting these lower doses.
ISSN:1361-6498
DOI:10.1088/1361-6498/acb780