The test-retest reliability and minimal detectable change of the six-minute walk test, timed up and go test, and 30-second chair stand test in people with epilepsy

The available evidence suggests that people with epilepsy have reduced cardio-respiratory fitness and muscle strength endurance, and impaired balance and mobility. The 6-minute walk test (6MWT), Timed Up and Go (TUG), and 30-second chair stand test (30CST) are physical performance tests frequently u...

Full description

Saved in:
Bibliographic Details
Published in:Physiotherapy theory and practice Vol. 40; no. 10; pp. 2298 - 2407
Main Authors: Aktar, Burcin, Balci, Birgul, Oztura, Ibrahim, Baklan, Baris
Format: Journal Article
Language:English
Published: England Taylor & Francis Ltd 01-10-2024
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The available evidence suggests that people with epilepsy have reduced cardio-respiratory fitness and muscle strength endurance, and impaired balance and mobility. The 6-minute walk test (6MWT), Timed Up and Go (TUG), and 30-second chair stand test (30CST) are physical performance tests frequently used in clinical practice. To establish the test-retest reliability and minimal detectable change of the 6MWT, TUG, and 30CST in people with epilepsy. The study was designed as an observational study. Forty-one people with epilepsy (23 females, 18 males; mean age 34.7 ± 10.4 years) participated. The 6MWT, TUG, and 30CST were tested by a trained physiotherapist during two sessions, which were conducted 7-14 days apart. The test-retest reliability of measures was assessed using the intra-class correlation coefficients (ICC) using two-way random effects and absolute agreement methods. The 95% limits of agreement, standard error of measurement (SEM), and minimal detectable change (MDC₉₅) were calculated. The 6MWT (ICC = 0.92, SEM = 15.8, MDC₉₅ = 43.8), TUG (ICC = 0.95, SEM = 3.2, MDC₉₅ = 0.5) and 30CST (ICC = 0.92, SEM = 1.0, MDC₉₅ = 2.8) performance measurements demonstrated excellent test-retest reliability. The 95% limits of agreement was calculated, as illustrated in a Bland-Altman plot. The 6MWT, TUG, and 30CST are reliable for measuring physical performance. The findings of this study can support researchers and clinicians to decide if a change score of a person with epilepsy is likely to be measurement error or true change.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:0959-3985
1532-5040
1532-5040
DOI:10.1080/09593985.2023.2237566