Study of the Scintillation Detector Prototype for the Upgraded Polarimeter at the Internal Target Station at the Nuclotron

The paper presents the performance studies of the scintillation detector prototype with SiPM readout using different types of the front-end electronics. The timing and position resolutions with LED have been obtained. These results can be applied for the proton and deuteron beams polarimetry at the...

Full description

Saved in:
Bibliographic Details
Published in:Physics of particles and nuclei letters Vol. 20; no. 5; pp. 1165 - 1168
Main Authors: Tishevsky, A. V., Alekseev, I. G., Volkov, I. S., Gurchin, Yu. V., Isupov, A. Yu, Kulevoy, T. V., Ladygin, V. P., Polozov, P. A., Reznikov, S. G., Svirida, D. N., Terekhin, A. A., Khrenov, A. N.
Format: Journal Article
Language:English
Published: Moscow Pleiades Publishing 01-10-2023
Springer Nature B.V
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The paper presents the performance studies of the scintillation detector prototype with SiPM readout using different types of the front-end electronics. The timing and position resolutions with LED have been obtained. These results can be applied for the proton and deuteron beams polarimetry at the Internal Target Station at Nuclotron.