The measurement of shear compliances for oriented polyethylene terephthalate sheet

Two techniques have been used to measure the shear compliances of one-way drawn uniplanar-axially-oriented polyethylene terephthalate (PET) sheet, draw ratio 5:1; a torsional method for all three compliances S sub(4) sub(4), S sub(5) sub(5) and S sub(6) sub(6), and a recently-developed simple-shear...

Full description

Saved in:
Bibliographic Details
Published in:Journal of materials science Vol. 15; no. 9; pp. 2354 - 2364
Main Authors: Lewis, E. L. V., Ward, I. M.
Format: Journal Article
Language:English
Published: 01-09-1980
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Two techniques have been used to measure the shear compliances of one-way drawn uniplanar-axially-oriented polyethylene terephthalate (PET) sheet, draw ratio 5:1; a torsional method for all three compliances S sub(4) sub(4), S sub(5) sub(5) and S sub(6) sub(6), and a recently-developed simple-shear method for S sub(4) sub(4) and S sub(6) sub(6). The two techniques gave values for the compliances in common which agreed very well. An examination of end effects in torsion has also been made. The determination of the three shear compliances complete the determination of all nine independent compliances for this PET sheet.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0022-2461
1573-4803
DOI:10.1007/BF00552328