Assessing effectiveness of cleaning and disinfection of equipment and environmental surfaces in cystic fibrosis clinics using an ATP assay
Infection control guidelines for cystic fibrosis (CF) stress cleaning of environmental surfaces and patientcare equipment in CF clinics. This multicenter study measured cleanliness of frequently touched surfaces in CF clinics using an ATP bioluminescence assay to assess the effectiveness of cleaning...
Saved in:
Published in: | Infection control and hospital epidemiology pp. 1 - 6 |
---|---|
Main Authors: | , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
United States
23-10-2024
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Infection control guidelines for cystic fibrosis (CF) stress cleaning of environmental surfaces and patientcare equipment in CF clinics. This multicenter study measured cleanliness of frequently touched surfaces in CF clinics using an ATP bioluminescence assay to assess the effectiveness of cleaning/disinfection and the impact of feedback.
Eight surfaces were tested across 19 clinics (10 pediatric, 9 adult) over 5 rounds of testing. Rounds 1 and 2 served as uncleaned baseline, and Round 3 occurring after routine cleaning. Rounds 4 and 5 were performed after feedback provided to staff and measured after cleaning. Pass rates defined as <250 relative light units were the primary outcome.
Of the 750 tests performed, 72% of surfaces passed at baseline, and 79%, 83%, and 85% of surfaces passed in Rounds 3, 4, and 5, respectively. The overall pass-rate was significantly higher in adult compared to pediatric clinics (86% vs 71%;
< 0.001). In pediatric clinics, blood pressure equipment and computer keyboards in the pulmonary function lab consistently passed, but the exam room patient/visitor chairs consistently failed in all rounds. In adult clinics blood pressure equipment, keyboards in exam rooms and exam tables passed in all rounds and no surface consistently failed.
We demonstrate the feasibility of an ATP bioluminescence assay to measure cleanliness of patient care equipment and surfaces in CF clinics. Pass rates improved after cleaning and feedback for certain surfaces. We found that surfaces are more challenging to keep clean in clinics taking care of younger patients. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0899-823X 1559-6834 1559-6834 |
DOI: | 10.1017/ice.2024.102 |