Different materials and techniques for accurate molding for adaptation in angled implants
OBJECTIVE: To evaluate the marginal misfit between intermediate and micro-unitmetal cylinder, by varying the angle of the implants, using two different types of material and different molding techniques. METHODS: A model was made with three implants (one perpendicular to the horizontal plane and two...
Saved in:
Published in: | RGO - Revista Gaúcha de Odontologia Vol. 62; no. 2; pp. 149 - 152 |
---|---|
Main Authors: | , , , , |
Format: | Journal Article |
Language: | English |
Published: |
01-06-2014
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | OBJECTIVE: To evaluate the marginal misfit between intermediate and micro-unitmetal cylinder, by varying the angle of the implants, using two different types of material and different molding techniques. METHODS: A model was made with three implants (one perpendicular to the horizontal plane and two inclined) using micro-unit intermediates. A rod attached to the master model served as a control condition to evaluate the suitability of the twenty specimens, carried out with the help of an optical stereomicroscope (Pantec, Brazil; Materials Testing Laboratory, São Leopoldo Mandic, Campinas, São Paulo). RESULTS: Evaluator reliability was assessed using theIntraclass Correlation Coefficient, obtaining 99.6% (excellent). There were significant differences between groups, and the Mann-Whitney test compared groups in pairs for a more accurate result. CONCLUSION: The group which presented the best behavior was open tray and condensation silicone and the worst result, that needed to be cast several times, was closed tray and condensation silicone.
OBJETIVO: Avaliar a desadaptação marginal entre intermediário micro-unit e cilindro metálicos, variando a angulação dos implantes, com dois tipos de materiais e diferentes técnicas de moldagem. MÉTODO: Modelo com três implantes (um perpendicular ao plano horizontal e dois inclinados) usando intermediários micro-units. Uma barra mestre acoplada ao modelo serviu de situação controle para avaliar a adaptação dos vinte corpos de prova, feitas com estereomicroscópio óptico. RESULTADOS: A confiabilidade do avaliador foi avaliada com Índice de Correlação Intraclasse, obtendo 99,6% (ótimo). Houve diferença estatisticamente significante entre os grupos, e com o teste Mann-Whitney comparou-se os grupos aos pares para um resultado mais preciso. CONCLUSÃO: O grupo que apresentou melhor comportamento foi o de tray aberta e silicone por condensação. O de pior resultado, que foi preciso ser moldado diversas vezes, foi o de tray fechada e silicone por condensação. |
---|---|
ISSN: | 0103-6971 1981-8637 |
DOI: | 10.1590/1981-8637201400020000072608 |