Computer-aided pulmonary nodule detection - performance of two CAD systems at different CT dose levels

To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). Multi-slice computed tomography (MSCT) data sets of...

Full description

Saved in:
Bibliographic Details
Published in:RöFo : Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebende Verfahren Vol. 181; no. 11; p. 1056
Main Authors: Hein, P A, Rogalla, P, Klessen, C, Lembcke, A, Romano, V C
Format: Journal Article
Language:English
Published: Germany 01-11-2009
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120 kV tube voltage (1 mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72 % and 62 % (CAD-1 vs. CAD-2) for SD-CT and with 73 % and 56 % for ULD-CT. Median false positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83 % and 61 % for SD-CT and to 89 % and 67 % for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p > 0.05). Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems.
ISSN:1438-9010
DOI:10.1055/s-0028-1109394