Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea
BACKGROUND The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of ap...
Saved in:
Published in: | Thorax Vol. 55; no. 4; pp. 302 - 307 |
---|---|
Main Authors: | , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
London
BMJ Publishing Group Ltd and British Thoracic Society
01-04-2000
BMJ BMJ Publishing Group LTD BMJ Group |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | BACKGROUND The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recovery of digitally recorded oxygen saturation was compared with PSG. METHODS Two hundred and forty six patients with suspected OSA were randomly selected for PSG and automated off line analysis of the digitally recorded oximeter signal. RESULTS The PSG derived apnoea hypopnoea index (AHI) and oximeter derived respiratory disturbance index (RDI) were highly correlated (R = 0.97). The mean (2SD) of the differences between AHI and RDI was 2.18 (12.34)/h. The sensitivity and specificity of the algorithm depended on the AHI and RDI criteria selected for OSA case designation. Using case designation criteria of 15/h for AHI and RDI, the sensitivity and specificity were 98% and 88%, respectively. If the PSG derived AHI included EEG based arousals as part of the hypopnoea definition, the mean (2SD) of the differences between RDI and AHI was –0.12 (15.62)/h and the sensitivity and specificity profile did not change significantly. CONCLUSIONS In a population of patients suspected of having OSA, off line automated analysis of the oximetry signal provides a close estimate of AHI as well as excellent diagnostic sensitivity and specificity for OSA. |
---|---|
AbstractList | BACKGROUNDThe gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recovery of digitally recorded oxygen saturation was compared with PSG.METHODSTwo hundred and forty six patients with suspected OSA were randomly selected for PSG and automated off line analysis of the digitally recorded oximeter signal.RESULTSThe PSG derived apnoea hypopnea index (AHI) and oximeter derived respiratory disturbance index (RDI) were highly correlated (R = 0.97). The mean (2SD) of the differences between AHI and RDI was 2.18 (12.34)/h. The sensitivity and specificity of the algorithm depended on the AHI and RDI criteria selected for OSA case designation. Using case designation criteria of 15/h for AHI and RDI, the sensitivity and specificity were 98% and 88%, respectively. If the PSG derived AHI included EEG based arousals as part of the hypopnea definition, the mean (2SD) of the differences between RDI and AHI was -0.12 (15. 62)/h and the sensitivity and specificity profile did not change significantly.CONCLUSIONSIn a population of patients suspected of having OSA, off line automated analysis of the oximetry signal provides a close estimate of AHI as well as excellent diagnostic sensitivity and specificity for OSA. BACKGROUND —The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recovery of digitally recorded oxygen saturation was compared with PSG. METHODS —Two hundred and forty six patients with suspected OSA were randomly selected for PSG and automated off line analysis of the digitally recorded oximeter signal. RESULTS —The PSG derived apnoea hypopnoea index (AHI) and oximeter derived respiratory disturbance index (RDI) were highly correlated ( R = 0.97). The mean (2SD) of the differences between AHI and RDI was 2.18 (12.34)/h. The sensitivity and specificity of the algorithm depended on the AHI and RDI criteria selected for OSA case designation. Using case designation criteria of 15/h for AHI and RDI, the sensitivity and specificity were 98% and 88%, respectively. If the PSG derived AHI included EEG based arousals as part of the hypopnoea definition, the mean (2SD) of the differences between RDI and AHI was -0.12 (15.62)/h and the sensitivity and specificity profile did not change significantly. CONCLUSIONS —In a population of patients suspected of having OSA, off line automated analysis of the oximetry signal provides a close estimate of AHI as well as excellent diagnostic sensitivity and specificity for OSA. BACKGROUND The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recovery of digitally recorded oxygen saturation was compared with PSG. METHODS Two hundred and forty six patients with suspected OSA were randomly selected for PSG and automated off line analysis of the digitally recorded oximeter signal. RESULTS The PSG derived apnoea hypopnoea index (AHI) and oximeter derived respiratory disturbance index (RDI) were highly correlated (R = 0.97). The mean (2SD) of the differences between AHI and RDI was 2.18 (12.34)/h. The sensitivity and specificity of the algorithm depended on the AHI and RDI criteria selected for OSA case designation. Using case designation criteria of 15/h for AHI and RDI, the sensitivity and specificity were 98% and 88%, respectively. If the PSG derived AHI included EEG based arousals as part of the hypopnoea definition, the mean (2SD) of the differences between RDI and AHI was –0.12 (15.62)/h and the sensitivity and specificity profile did not change significantly. CONCLUSIONS In a population of patients suspected of having OSA, off line automated analysis of the oximetry signal provides a close estimate of AHI as well as excellent diagnostic sensitivity and specificity for OSA. The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recovery of digitally recorded oxygen saturation was compared with PSG. Two hundred and forty six patients with suspected OSA were randomly selected for PSG and automated off line analysis of the digitally recorded oximeter signal. The PSG derived apnoea hypopnea index (AHI) and oximeter derived respiratory disturbance index (RDI) were highly correlated (R = 0.97). The mean (2SD) of the differences between AHI and RDI was 2.18 (12.34)/h. The sensitivity and specificity of the algorithm depended on the AHI and RDI criteria selected for OSA case designation. Using case designation criteria of 15/h for AHI and RDI, the sensitivity and specificity were 98% and 88%, respectively. If the PSG derived AHI included EEG based arousals as part of the hypopnea definition, the mean (2SD) of the differences between RDI and AHI was -0.12 (15. 62)/h and the sensitivity and specificity profile did not change significantly. In a population of patients suspected of having OSA, off line automated analysis of the oximetry signal provides a close estimate of AHI as well as excellent diagnostic sensitivity and specificity for OSA. |
Author | Tsai, Willis H Masuda, Akira Whitelaw, William A Remmers, John E Flemons, W Ward Hajduk, Eric Vázquez, Juan-Carlos Brant, Rollin |
AuthorAffiliation | Division of Respiratory Medicine, Department of Medicine, University of Calgary, Calgary, Alberta, Canada T2N 4N1 |
AuthorAffiliation_xml | – name: Division of Respiratory Medicine, Department of Medicine, University of Calgary, Calgary, Alberta, Canada T2N 4N1 |
Author_xml | – sequence: 1 givenname: Juan-Carlos surname: Vázquez fullname: Vázquez, Juan-Carlos – sequence: 2 givenname: Willis H surname: Tsai fullname: Tsai, Willis H – sequence: 3 givenname: W Ward surname: Flemons fullname: Flemons, W Ward – sequence: 4 givenname: Akira surname: Masuda fullname: Masuda, Akira – sequence: 5 givenname: Rollin surname: Brant fullname: Brant, Rollin – sequence: 6 givenname: Eric surname: Hajduk fullname: Hajduk, Eric – sequence: 7 givenname: William A surname: Whitelaw fullname: Whitelaw, William A – sequence: 8 givenname: John E surname: Remmers fullname: Remmers, John E |
BackLink | http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1300921$$DView record in Pascal Francis https://www.ncbi.nlm.nih.gov/pubmed/10722770$$D View this record in MEDLINE/PubMed |
BookMark | eNqFkd1rFDEUxYO02G312TcZsPggzDbfyb4IZWtboSjix2vIZDK7WWeSNcmU3f_elFlq9cWnQO7vHu455xQc-eAtAK8QnCNE-EVeh6h3c8bmdE4gfgZmiHJZE7zgR2AGIYU1J4KfgNOUNhBCiZB4Dk4QFBgLAWfg6-WYw6CzbSvtdb9PLlWhq1q3cln3Vdi5wea4r5yv8tqWf73y4QCFJuU4muzubZV6a7eV3vpg9Qtw3Ok-2ZeH9wx8v_7wbXlb332--bi8vKsbJlmuGyskpKLtMIYdtYYxIiVlrUFEUkRxK02zYBKatjHCct6Rrm2EaCxquaAckTPwftLdjs1gW2N9jrpX2-gGHfcqaKf-nni3Vqtwr5CgTBBRBN4eBGL4NdqU1eCSsX2vvQ1jUgJBVKKkBXzzD7gJYyx5paIlkcSkGCnUxUSZGFKKtns8BUH1UJea6lKMKapKXWXj9VMHT_ipnwKcHwCdjO67qL1x6Q9HIFzghyTqCXMp293jWMefihejTH36sVT46pZ9oZCr68K_m_hm2Pz3yN81Er6d |
CODEN | THORA7 |
CitedBy_id | crossref_primary_10_1016_j_otot_2007_01_005 crossref_primary_10_1109_TBME_2011_2167971 crossref_primary_10_1016_j_medengphy_2011_11_009 crossref_primary_10_1016_j_ijporl_2006_08_009 crossref_primary_10_4103_lungindia_lungindia_302_19 crossref_primary_10_1046_j_1365_2869_2003_00330_x crossref_primary_10_1152_ajprenal_00290_2019 crossref_primary_10_1016_j_bjoms_2012_07_004 crossref_primary_10_5665_sleep_1592 crossref_primary_10_4103_1687_8426_193647 crossref_primary_10_1179_016164105X18359 crossref_primary_10_1164_rccm_201502_0383OC crossref_primary_10_5665_sleep_4984 crossref_primary_10_1053_smrv_2001_0205 crossref_primary_10_1016_j_cmpb_2008_04_012 crossref_primary_10_1164_ajrccm_165_2_2010008 crossref_primary_10_1016_j_fmc_2018_09_003 crossref_primary_10_1258_jtt_2009_081105 crossref_primary_10_1016_S0761_8425_10_70017_6 crossref_primary_10_1016_S2173_5115_07_70349_4 crossref_primary_10_1016_j_cjca_2014_12_032 crossref_primary_10_1111_jsr_12358 crossref_primary_10_1007_s40846_019_00479_6 crossref_primary_10_1016_j_anl_2022_03_001 crossref_primary_10_1109_TBME_2006_883821 crossref_primary_10_1111_sbr_12097 crossref_primary_10_1378_chest_124_4_1543 crossref_primary_10_1024_1661_8157_a003599 crossref_primary_10_3109_03091902_2010_481034 crossref_primary_10_14814_phy2_14376 crossref_primary_10_4065_80_4_455 crossref_primary_10_1016_j_ijcard_2018_07_124 crossref_primary_10_5665_sleep_5046 crossref_primary_10_1378_chest_124_5_1702 crossref_primary_10_1111_j_1440_1843_2010_01797_x crossref_primary_10_1109_TBME_2010_2056924 crossref_primary_10_1164_rccm_200310_1360OC crossref_primary_10_1007_s11517_007_0280_0 crossref_primary_10_1080_15402002_2015_1017098 crossref_primary_10_1152_japplphysiol_00312_2011 crossref_primary_10_1007_s11325_017_1547_9 crossref_primary_10_1007_s00392_018_1238_y crossref_primary_10_1056_NEJMcp012849 crossref_primary_10_1186_1465_9921_9_56 crossref_primary_10_1007_s11325_008_0187_5 crossref_primary_10_1046_j_1540_8167_2003_03097_x crossref_primary_10_1111_jsr_12465 crossref_primary_10_1016_j_expneurol_2021_113897 crossref_primary_10_1016_j_ejcdt_2014_11_018 crossref_primary_10_1016_j_arcmed_2004_11_012 crossref_primary_10_1016_S1579_2129_07_60015_9 crossref_primary_10_5005_ijsm_1_2_65 crossref_primary_10_1109_JBHI_2020_2967872 crossref_primary_10_1253_circj_69_1320 crossref_primary_10_1378_chest_08_0057 crossref_primary_10_1097_IAE_0b013e318259568b crossref_primary_10_1016_j_medcli_2017_11_024 crossref_primary_10_1109_JBHI_2018_2817368 crossref_primary_10_35366_94637 crossref_primary_10_14789_pjmj_51_311 crossref_primary_10_1046_j_1365_2869_2000_00218_x crossref_primary_10_1378_chest_121_6_1730 crossref_primary_10_1136_gpsych_2020_100260 crossref_primary_10_2165_00002512_200421050_00003 crossref_primary_10_1111_j_1365_2869_2007_00590_1_x crossref_primary_10_1097_01_BCR_0000124793_99886_6A crossref_primary_10_1088_0967_3334_23_2_201 crossref_primary_10_1117_1_JBO_21_3_035006 crossref_primary_10_1016_j_jsmc_2011_05_010 crossref_primary_10_1016_j_medengphy_2014_05_008 crossref_primary_10_1111_j_1442_2050_2008_00877_x crossref_primary_10_1016_j_medcle_2017_11_045 crossref_primary_10_1016_S1389_9457_01_00122_8 crossref_primary_10_1164_rccm_200112_110OC crossref_primary_10_1164_rccm_201403_0526OC crossref_primary_10_1016_S1579_2129_07_60150_5 crossref_primary_10_1016_j_apmr_2013_12_011 crossref_primary_10_1016_j_compbiomed_2017_06_015 crossref_primary_10_1016_j_ijporl_2008_08_016 crossref_primary_10_1016_j_jamda_2014_03_011 crossref_primary_10_1007_s11325_011_0603_0 crossref_primary_10_1016_j_aap_2007_04_011 crossref_primary_10_1378_chest_124_5_1694 crossref_primary_10_1097_00063198_200111000_00002 crossref_primary_10_1016_j_jpsychores_2010_09_009 crossref_primary_10_1007_s11325_013_0859_7 crossref_primary_10_1053_rmed_2000_0860 crossref_primary_10_1378_chest_11_1809 crossref_primary_10_1007_s11325_019_01861_z crossref_primary_10_1007_s11325_024_03016_1 crossref_primary_10_1378_chest_121_6_1748 crossref_primary_10_2147_NSS_S355369 crossref_primary_10_1007_s11325_015_1274_z crossref_primary_10_1111_anae_13668 crossref_primary_10_1113_JP272967 crossref_primary_10_1016_j_resp_2008_10_011 crossref_primary_10_1097_SCS_0000000000005530 crossref_primary_10_1097_00005537_200410000_00030 crossref_primary_10_1007_s11517_010_0646_6 crossref_primary_10_1111_j_1365_2869_2008_00726_x crossref_primary_10_1016_S0272_5231_03_00018_2 crossref_primary_10_3390_s23094267 crossref_primary_10_1007_s11325_008_0217_3 crossref_primary_10_1258_jtt_2010_100205 crossref_primary_10_1378_chest_07_0312 crossref_primary_10_1016_S1389_9457_02_00234_4 crossref_primary_10_1111_j_1460_9592_2009_02961_x crossref_primary_10_1213_ANE_0b013e318248f4f5 crossref_primary_10_1109_JBHI_2013_2266279 crossref_primary_10_1152_jappl_2001_91_1_408 crossref_primary_10_1016_S1389_9457_01_00129_0 crossref_primary_10_1016_j_rmed_2003_11_009 crossref_primary_10_1111_jsr_12558 crossref_primary_10_1016_j_atherosclerosis_2012_03_036 crossref_primary_10_1038_s41415_023_6267_x crossref_primary_10_1016_j_bspc_2020_102062 crossref_primary_10_1113_EP086845 crossref_primary_10_1371_journal_pone_0019029 crossref_primary_10_1378_chest_120_2_625 crossref_primary_10_1007_s11325_013_0812_9 crossref_primary_10_1007_s11325_005_0038_6 crossref_primary_10_1155_2016_7170610 crossref_primary_10_1016_j_expneurol_2021_113852 crossref_primary_10_1016_S0873_2159_15_30363_9 crossref_primary_10_1155_2018_1435203 crossref_primary_10_1016_j_maturitas_2006_03_007 crossref_primary_10_1186_s12890_015_0017_z crossref_primary_10_1016_j_cmpb_2008_05_006 crossref_primary_10_1016_j_bspc_2016_12_013 crossref_primary_10_1016_S0212_6567_03_79236_1 crossref_primary_10_22581_muet1982_1901_01 crossref_primary_10_1016_j_medengphy_2006_05_013 crossref_primary_10_3810_pgm_2008_07_1790 crossref_primary_10_1177_1359105309344895 crossref_primary_10_1016_j_sleep_2004_03_004 crossref_primary_10_1109_TITB_2009_2034975 crossref_primary_10_1016_j_medengphy_2009_05_010 crossref_primary_10_1152_japplphysiol_00561_2007 crossref_primary_10_1016_j_cmpb_2006_09_012 crossref_primary_10_1016_j_ijcard_2018_04_076 crossref_primary_10_1093_sleep_34_3_363 crossref_primary_10_1111_j_1365_2869_2011_00927_x crossref_primary_10_1088_0967_3334_31_3_007 crossref_primary_10_1016_j_medengphy_2011_10_015 crossref_primary_10_1016_j_sleep_2016_09_012 crossref_primary_10_1093_sleep_zsaa228 crossref_primary_10_1186_1471_2288_9_50 crossref_primary_10_1157_13112962 crossref_primary_10_1016_j_ijom_2007_12_005 crossref_primary_10_1136_bmjopen_2018_024632 crossref_primary_10_5665_SLEEP_1162 crossref_primary_10_1164_rccm_200609_1271OC crossref_primary_10_1183_13993003_02351_2018 crossref_primary_10_1164_rccm_200310_1446OC crossref_primary_10_5665_sleep_3048 crossref_primary_10_1157_13096996 crossref_primary_10_14814_phy2_15677 crossref_primary_10_5005_jp_journals_10003_1185 crossref_primary_10_1164_rccm_200308_1124PP crossref_primary_10_1097_WNP_0b013e31826244ae crossref_primary_10_1161_JAHA_114_000875 crossref_primary_10_1016_j_msom_2016_04_002 crossref_primary_10_3923_pjbs_2009_276_280 |
ContentType | Journal Article |
Copyright | British Thoracic Society 2000 INIST-CNRS Copyright: 2000 British Thoracic Society |
Copyright_xml | – notice: British Thoracic Society – notice: 2000 INIST-CNRS – notice: Copyright: 2000 British Thoracic Society |
DBID | BSCLL IQODW CGR CUY CVF ECM EIF NPM AAYXX CITATION 3V. 7X7 7XB 88E 8FI 8FJ 8FK ABUWG AFKRA BENPR BTHHO CCPQU FYUFA GHDGH K9. M0S M1P PQEST PQQKQ PQUKI PRINS 7X8 5PM |
DOI | 10.1136/thorax.55.4.302 |
DatabaseName | Istex Pascal-Francis Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed CrossRef ProQuest Central (Corporate) ProQuest_Health & Medical Collection ProQuest Central (purchase pre-March 2016) Medical Database (Alumni Edition) Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central BMJ Journals ProQuest One Community College Health Research Premium Collection Health Research Premium Collection (Alumni) ProQuest Health & Medical Complete (Alumni) Health & Medical Collection (Alumni Edition) PML(ProQuest Medical Library) ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China MEDLINE - Academic PubMed Central (Full Participant titles) |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) CrossRef ProQuest One Academic Eastern Edition ProQuest Health & Medical Complete (Alumni) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest Hospital Collection Health Research Premium Collection (Alumni) ProQuest Central China ProQuest Hospital Collection (Alumni) ProQuest Central ProQuest Health & Medical Complete Health Research Premium Collection ProQuest Medical Library ProQuest One Academic UKI Edition Health and Medicine Complete (Alumni Edition) BMJ Journals ProQuest One Academic ProQuest Medical Library (Alumni) ProQuest Central (Alumni) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE ProQuest One Academic Eastern Edition |
Database_xml | – sequence: 1 dbid: ECM name: MEDLINE url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1468-3296 |
EndPage | 307 |
ExternalDocumentID | 4027020181 10_1136_thorax_55_4_302 10722770 1300921 ark_67375_NVC_2DH5Q406_F thoraxjnl |
Genre | Clinical Trial Randomized Controlled Trial Research Support, Non-U.S. Gov't Journal Article |
GeographicLocations | United States--US |
GeographicLocations_xml | – name: United States--US |
GroupedDBID | --- .55 .GJ .VT 08G 0R~ 123 18M 29Q 2WC 354 39C 3O- 3V. 4.4 40O 53G 5RE 5VS 6PF 7X7 7~S 88E 8F7 8FI 8FJ 8R4 8R5 AAHLL AAKAS AAOJX AAWJN AAWTL AAYEP ABAAH ABJNI ABKDF ABMQD ABOCM ABTFR ABUWG ABVAJ ACGFO ACGFS ACGTL ACHTP ACMFJ ACOFX ACTZY ADBBV ADCEG ADZCM AENEX AFKRA AFWFF AHMBA AHNKE AHQMW AJYBZ ALIPV ALMA_UNASSIGNED_HOLDINGS ASPBG AVWKF AZFZN BAWUL BENPR BLJBA BOMFT BPHCQ BTFSW BTHHO BVXVI C45 CAG CCPQU COF CS3 CXRWF DIK DU5 E3Z EBS EJD F5P FEDTE FYUFA GX1 H13 HAJ HMCUK HVGLF HYE HZ~ IAO IEA IH2 IHR IOF ITC J5H KQ8 L7B M1P N4W N9A NTWIH NXWIF O9- OK1 OVD P2P PQQKQ PROAC PSQYO Q2X R53 RHF RHI RMJ RPM RV8 TEORI TR2 UAW UKHRP UYXKK V24 VM9 VVN W8F WH7 X7M YFH YOC YQY ZCG ZGI BSCLL ABMYL AQVPL BHJZB BJGMD IQODW ZA5 CGR CUY CVF ECM EIF NPM AAYXX CITATION 7XB 8FK K9. PQEST PQUKI PRINS 7X8 5PM |
ID | FETCH-LOGICAL-b585t-be78047df220f4ec5538845dc1384142d8cb9580cdbc7e66f3fdb77be1d674613 |
IEDL.DBID | RPM |
ISSN | 0040-6376 |
IngestDate | Tue Sep 17 21:23:47 EDT 2024 Fri Oct 25 07:31:57 EDT 2024 Thu Oct 10 19:33:53 EDT 2024 Fri Aug 23 01:00:15 EDT 2024 Sat Sep 28 08:37:22 EDT 2024 Fri Mar 22 17:06:25 EDT 2024 Wed Oct 30 09:46:13 EDT 2024 Tue Nov 26 19:35:39 EST 2024 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 4 |
Keywords | Human Oxymetry Sleep apnea syndrome Respiratory disease Sleep disorder Exploration Polysomnography Algorithm Electrodiagnosis Diagnosis Technique Automatic analysis Comparative study |
Language | English |
License | CC BY 4.0 |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-b585t-be78047df220f4ec5538845dc1384142d8cb9580cdbc7e66f3fdb77be1d674613 |
Notes | PMID:10722770 Dr J E Remmers href:thoraxjnl-55-302.pdf istex:4B12B518AB4DC5807964E236046268BF10C03150 local:thoraxjnl;55/4/302 ark:/67375/NVC-2DH5Q406-F ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 ObjectType-News-3 content type line 23 |
OpenAccessLink | https://thorax.bmj.com/content/thoraxjnl/55/4/302.full.pdf |
PMID | 10722770 |
PQID | 1781823047 |
PQPubID | 2041050 |
PageCount | 6 |
ParticipantIDs | pubmedcentral_primary_oai_pubmedcentral_nih_gov_1745737 proquest_miscellaneous_71013294 proquest_journals_1781823047 crossref_primary_10_1136_thorax_55_4_302 pubmed_primary_10722770 pascalfrancis_primary_1300921 istex_primary_ark_67375_NVC_2DH5Q406_F bmj_primary_10_1136_thorax_55_4_302 |
PublicationCentury | 2000 |
PublicationDate | 2000-04-01 |
PublicationDateYYYYMMDD | 2000-04-01 |
PublicationDate_xml | – month: 04 year: 2000 text: 2000-04-01 day: 01 |
PublicationDecade | 2000 |
PublicationPlace | London |
PublicationPlace_xml | – name: London – name: England |
PublicationTitle | Thorax |
PublicationTitleAlternate | Thorax |
PublicationYear | 2000 |
Publisher | BMJ Publishing Group Ltd and British Thoracic Society BMJ BMJ Publishing Group LTD BMJ Group |
Publisher_xml | – name: BMJ Publishing Group Ltd and British Thoracic Society – name: BMJ – name: BMJ Publishing Group LTD – name: BMJ Group |
References | Farney, Walker, Jensen 1986; 89 Douglas, Thomas, Jan 1992; 339 Williams, Yu, Santiago 1991; 100 Redline, Tosteson, Boucher 1991; 100 Issa, Morrison, Hajduk 1993; 148 Stoohs, Guilleminault 1992; 101 Young, Palta, Dempsey 1993; 328 Gould, Whyte, Rhind 1988; 137 Cooper, Veale, Griffiths 1991; 46 Ancoli-Israel, Kripke, Mason 1981; 4 Tsai, Flemons, Whitelaw 1999; 159 Orr, Eiken, Pegram 1994; 105 Gyulay, Olson, Hensley 1993; 147 1994; 17 Bland, Altman 1986; i Hla, Young, Bidwell 1994; 120 Séries, Marc, Cormier 1993; 119 White, Gribb, Wall 1995; 18 |
References_xml | – volume: 137 start-page: 895 year: 1988 article-title: The sleep hypopnea syndrome. publication-title: Am Rev Respir Dis contributor: fullname: Rhind – volume: 46 start-page: 586 year: 1991 article-title: Value of nocturnal oxygen saturation as a screening test for sleep apnoea. publication-title: Thorax contributor: fullname: Griffiths – volume: 119 start-page: 449 year: 1993 article-title: Utility of nocturnal home oximetry for case finding in patients with suspected sleep apnea syndrome. publication-title: Ann Intern Med contributor: fullname: Cormier – volume: 148 start-page: 1023 year: 1993 article-title: Digital monitoring of sleep disordered breathing using snoring sound and arterial oxygen saturation. publication-title: Am Rev Respir Dis contributor: fullname: Hajduk – volume: 101 start-page: 1221 year: 1992 article-title: MESAM 4: an ambulatory device for the detection of patients at risk for obstructive sleep apnea syndrome (OSAS). publication-title: Chest contributor: fullname: Guilleminault – volume: 120 start-page: 382 year: 1994 article-title: Sleep apnoea and hypertension: a population-based study. publication-title: Ann Intern Med contributor: fullname: Bidwell – volume: 100 start-page: 631 year: 1991 article-title: Screening for sleep apnea using pulse oximetry and a clinical score. publication-title: Chest contributor: fullname: Santiago – volume: 339 start-page: 347 year: 1992 article-title: Clinical value of polysomnography. publication-title: Lancet contributor: fullname: Jan – volume: 159 start-page: 43 year: 1999 article-title: A comparison of apnoea-hypopnea indices derived from different definitions of hypopnea. publication-title: Am J Respir Crit Care Med contributor: fullname: Whitelaw – volume: 89 start-page: 533 year: 1986 article-title: Ear oximetry to detect apnoea and differentiate rapid eye movement (REM) and non-REM (NREM) sleep. Screening for the sleep apnea syndrome. publication-title: Chest contributor: fullname: Jensen – volume: 147 start-page: 50 year: 1993 article-title: A comparison of clinical assessment and home oximetry in the diagnosis of obstructive sleep apnea. publication-title: Am Rev Respir Dis contributor: fullname: Hensley – volume: i start-page: 307 year: 1986 article-title: Statistical methods for assessing agreement between two methods of clinical measurement. publication-title: Lancet contributor: fullname: Altman – volume: 105 start-page: 160 year: 1994 article-title: A laboratory validation study of a portable system for remote recording of sleep-related breathing disorders. publication-title: Chest contributor: fullname: Pegram – volume: 4 start-page: 283 year: 1981 article-title: Comparisons of home sleep recordings and polysomnograms in older adults with sleep disorders. publication-title: Sleep contributor: fullname: Mason – volume: 100 start-page: 1281 year: 1991 article-title: Measurement of sleep-related breathing disturbances in epidemiologic studies. Assessment of the validity and reproducibility of a portable monitoring device. publication-title: Chest contributor: fullname: Boucher – volume: 18 start-page: 115 year: 1995 article-title: Assessment of accuracy and analysis time of a novel device to monitor sleep and breathing in the home. publication-title: Sleep contributor: fullname: Wall – volume: 328 start-page: 1230 year: 1993 article-title: The occurrence of sleep-disordered breathing among middle-aged adults. publication-title: N Engl J Med contributor: fullname: Dempsey – volume: 17 start-page: 378 year: 1994 article-title: ASDA Standards of Practice: Portable recording in the assessment of obstructive sleep apnea. publication-title: Sleep |
SSID | ssj0008117 |
Score | 2.1659896 |
Snippet | BACKGROUND The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money.... The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money.... BACKGROUNDThe gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money.... BACKGROUND —The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money.... |
SourceID | pubmedcentral proquest crossref pubmed pascalfrancis istex bmj |
SourceType | Open Access Repository Aggregation Database Index Database Publisher |
StartPage | 302 |
SubjectTerms | Adult Aged Aged, 80 and over Algorithms Angina pectoris Automation Biological and medical sciences Cardiovascular disease Coronary vessels Female Home environment Humans Investigative techniques, diagnostic techniques (general aspects) Laboratories Male Medical sciences Middle Aged Original oximetry Oximetry - methods Oxygen saturation Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques polysomnography Polysomnography - methods portable monitor Prospective Studies Respiratory system Sensitivity and Specificity Sleep apnea Sleep Apnea Syndromes - diagnosis sleep apnoea |
Title | Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea |
URI | https://thorax.bmj.com/content/55/4/302.full https://api.istex.fr/ark:/67375/NVC-2DH5Q406-F/fulltext.pdf https://www.ncbi.nlm.nih.gov/pubmed/10722770 https://www.proquest.com/docview/1781823047 https://search.proquest.com/docview/71013294 https://pubmed.ncbi.nlm.nih.gov/PMC1745737 |
Volume | 55 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3fb9MwED7RISFeEL8JbMMSCPGSNontOHmculVFaBNogHiz4tjeAmtSLS0q_z1nJykrQkLiNbaj5O5sfyd__g7gNW6ZJlcZC43gNmSZLUNF8yK0OhcFN8ZQ5S4Kz8_F2dfs-MTJ5PDhLown7ZeqGtdXi3FdXXpu5XJRTgae2OTD6RRRNBdUTEYwQmw4pOj98utuTg5UuRSnT6_nE9N0srpEs27GnI_ZmEa-kE0kkkS4SsUjtfi2szfddmbeOK5k0aK5bFfn4m9A9E8-5Y0NanYf7vXIkhx1f_AAbpn6Idw57c_OH8H50XrVID41mhS9EglpLNHVhasbQppNtTCr65-kqgmCQnzuOXhdp0b1OrM_DGmvjFmSYlk3pngMn2cnn6bzsC-pECrMC1ahMk5wSGibJJFlpuS43mWM6zKmGYtZorNS5TyLSq1KYdLUUquVEMrEOhUMt_4nsFc3tXkGRFuPjRDPUcoMw0EJ0xGzSVkgBFFRAK_QpHLZiWZIn2zQVHY-kJxLJtEHAbwdTP7vrm-8S7b9iuvvjpYmuDz7MpXJ8Zx_RHgiZwEc7Pjs94upk5iKA9gffCj7GdvKWCB08YeQAbzcNuNccwcoRW2adSsRjWHynrMAnnYOv_HJXRwFIHZCYdvBqXjvtmBwezXvPpif__fIF3C30wdwdKJ92MN4MAcwavX6EHOEd-8P_fz4BUZCE5E |
link.rule.ids | 230,315,729,782,786,887,27933,27934,53800,53802 |
linkProvider | National Library of Medicine |
linkToHtml | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFD6imwS8cL8ENhYJhHhJmsR2nDxO3aoi1gq0gXiz4thm2dakWlpU_j3HuZQVISHtNXai5Fzi78ifvwPwDpdMncqEepoz49HE5J4kaeYZlfKMaa2JtAeFJ6d89j05OrYyOaw_C9OQ9nNZ-OXV3C-L84ZbuZjnw54nNvw8HSGKZpzw4QB2MV-DoC_Sux-wPTvZk-ViTKBO0Sck8XB5joZd-4z51CdB08om4FHEba_igZxfbK1Ou9bQa8uWzGo0mGk7XfwLiv7NqLyxRI0f3vLjHsGDDpO6h-3wY7ijyydwd9rtuj-F08PVskJkq5WbdRombmVcVfywHUfcal3M9fL6l1uULsJJvN6w99pJlewUan9qt77SeuFmi7LS2TP4Oj4-G028rhmDJ7GiWHpSW6kirkwUBYbqnKHlE8pUHpKEhjRSSS5TlgS5kjnXcWyIUZJzqUMVc4qg4TnslFWpX4KrTIOqEAkSQjXFmyKqAmqiPEPwIgMH3qIrxKKV2xBNmUJi0fpOMCaoQN858KF31f-nvm9cuZmXXV9aQhtnYvZtJKKjCfuCwEaMHdjf8vWfBxMrThU6sNf7XnS5XouQI-hpti8dONgMY5barZes1NWqFojjsOxPqQMv2kC58cpt_DnAt0JoM8Hqf2-PYOQ0OuBdpLy69Z0HcG9yNj0RJx9nn17D_VZlwJKS9mAHY0Pvw6BWqzdNdv0GfQAoIg |
linkToPdf | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1bb9MwFD6imzTxwp2RsTFLIMRLmovtOH2c2lVFsGpogHiz4thmYWsSrS0q_57jJC0rQkKC1-Q4Ss4l_ix__g7AK5wyzUClzDeCW5-lNvcVHWS-1QORcWMMVe6g8ORCTL-ko1Mnk7Np9dWQ9nNV9MvrWb8sLhtuZT3LgzVPLDg_GyKK5oKKoNY26MEu1mwYrxfq3U_YnZ9cE-YSLKJO1SeiSbC4ROeu-pz3WZ-GTTubUMSxcP2Ke2r2bWuG2nXOXjnGZDZHp9m228Wf4OjvrMpb09T4_n984AO412FTctKaPIQ7pnwEe2fd7vtjuDhZLipEuEaTrNMyIZUluvjqOo-QalXMzOLmBylKgrASrzcsvtaoUp1S7XdD5tfG1CSry8pkT-DT-PTjcOJ3TRl8hSuLha-MkywS2sZxaJnJOXo_ZVznEU1ZxGKd5mrA0zDXKhcmSSy1WgmhTKQTwRA8PIWdsirNMyDaNugKESGlzDAcFDMdMhvnGYIYFXrwEsMh61Z2QzbLFZrINn6Sc8kkxs-DN-tw_d30dRPOjV12c-WIbYLL6eehjEcT_gEBjhx7cLQV718Ppk6kKvLgcB1_2dX8XEYCwU-zjenB8eY2VqvbgslKUy3nEvEcLv8HzIP9NlluvXKbgx6IrTTaGDgd8O07mD2NHniXLQf_PPIY9s5HY_n-7fTdc7jbig04btIh7GBqmCPozfXyRVNgPwHKqyqi |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Automated+analysis+of+digital+oximetry+in+the+diagnosis+of+obstructive+sleep+apnoea&rft.jtitle=Thorax&rft.au=Vazquez%2C+Juan-Carlos&rft.au=Tsai%2C+Willis+H&rft.au=Flemons%2C+W+Ward&rft.au=Masuda%2C+Akira&rft.date=2000-04-01&rft.pub=BMJ+Publishing+Group+LTD&rft.issn=0040-6376&rft.eissn=1468-3296&rft.volume=55&rft.issue=4&rft.spage=302&rft_id=info:doi/10.1136%2Fthorax.55.4.302&rft.externalDBID=HAS_PDF_LINK&rft.externalDocID=4027020181 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0040-6376&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0040-6376&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0040-6376&client=summon |