Eosinopenia is a reliable marker of sepsis on admission to medical intensive care units

Eosinopenia is a cheap and forgotten marker of acute infection that has not been evaluated previously in intensive care units (ICUs). The aim of the present study was to test the value of eosinopenia in the diagnosis of sepsis in patients admitted to ICUs. A prospective study of consecutive adult pa...

Full description

Saved in:
Bibliographic Details
Published in:Critical care (London, England) Vol. 12; no. 2; p. R59
Main Authors: Abidi, Khalid, Khoudri, Ibtissam, Belayachi, Jihane, Madani, Naoufel, Zekraoui, Aicha, Zeggwagh, Amine Ali, Abouqal, Redouane
Format: Journal Article
Language:English
Published: England BioMed Central Ltd 01-01-2008
National Library of Medicine - MEDLINE Abstracts
BioMed Central
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Eosinopenia is a cheap and forgotten marker of acute infection that has not been evaluated previously in intensive care units (ICUs). The aim of the present study was to test the value of eosinopenia in the diagnosis of sepsis in patients admitted to ICUs. A prospective study of consecutive adult patients admitted to a 12-bed medical ICU was performed. Eosinophils were measured at ICU admission. Two intensivists blinded to the eosinophils classified patients as negative or with systemic inflammatory response syndrome (SIRS), sepsis, severe sepsis, or septic shock. A total of 177 patients were enrolled. In discriminating noninfected (negative + SIRS) and infected (sepsis + severe sepsis + septic shock) groups, the area under the receiver operating characteristic curve was 0.89 (95% confidence interval (CI), 0.83 to 0.94). Eosinophils at <50 cells/mm3 yielded a sensitivity of 80% (95% CI, 71% to 86%), a specificity of 91% (95% CI, 79% to 96%), a positive likelihood ratio of 9.12 (95% CI, 3.9 to 21), and a negative likelihood ratio of 0.21(95% CI, 0.15 to 0.31). In discriminating SIRS and infected groups, the area under the receiver operating characteristic curve was 0.84 (95% CI, 0.74 to 0.94). Eosinophils at <40 cells/mm3 yielded a sensitivity of 80% (95% CI, 71% to 86%), a specificity of 80% (95% CI, 55% to 93%), a positive likelihood ratio of 4 (95% CI, 1.65 to 9.65), and a negative likelihood ratio of 0.25 (95% CI, 0.17 to 0.36). Eosinopenia is a good diagnostic marker in distinguishing between noninfection and infection, but is a moderate marker in discriminating between SIRS and infection in newly admitted critically ill patients. Eosinopenia may become a helpful clinical tool in ICU practices.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1364-8535
1466-609X
1364-8535
DOI:10.1186/cc6883