Endovascular treatment of intracranial aneurysms using the Derivo Embolization Device: a multicenter experience

Flow diversion is the first-line treatment for several types of intracranial aneurysms. We report on a large series of patients treated with the Derivo Embolization Device who underwent a 1-year angiographic control follow-up. We performed a multicenter retrospective analysis of prospectively collec...

Full description

Saved in:
Bibliographic Details
Published in:Journal of neurointerventional surgery Vol. 15; no. 8; p. 776
Main Authors: Chagas Lourenço, Galileu, Dantas, François, Silva E Carvalho, Tiago, Firmino, Róberti Uili Rodrigues, Quesado Filgueiras Filho, Marcelo, Tosello, Renato Tavares, José Leão, Cláudio, Leo Piske, Ronie, Zenóbio Darwich, Rogério
Format: Journal Article
Language:English
Published: England 01-08-2023
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Flow diversion is the first-line treatment for several types of intracranial aneurysms. We report on a large series of patients treated with the Derivo Embolization Device who underwent a 1-year angiographic control follow-up. We performed a multicenter retrospective analysis of prospectively collected data, designed to evaluate the clinical and angiographic results of treatment of intracranial aneurysms with the Derivo Flow Diverter. The primary endpoint was complete occlusion of the aneurysm within 12 months, which was evaluated using DSA. The secondary endpoint was the absence of any serious adverse events. Univariate and multivariate logistic regression analyses were performed to analyze the data. The study was conducted from December 2016 to September 2019 and enrolled 127 patients with 177 intracranial aneurysms, treated at three different centers. Efficacy at 6 months was 70.1% (122/174) for total occlusion and 87.3% (152/174) for favorable occlusion and, at 12 months, it was 83.3% (145/174) for total occlusion and 97.7% (170/174) for favorable occlusion. Regarding safety concerns, 97.6% (124/127) of patients did not experience severe adverse effects during the follow-up period of 12 months, and there was no procedure-related mortality. The Derivo Embolization Device, achieving a total occlusion rate of 83.3% and a favorable occlusion rate of 97.7% in a 1-year angiographic control study of 174 aneurysms with minor morbidity and no intervention-related mortality, is a safe and effective treatment for intracranial aneurysms.
ISSN:1759-8486
DOI:10.1136/neurintsurg-2022-018648