Improved simplified calibration procedure for a high-cycle accumulation model
The high-cycle accumulation (HCA) model proposed by Niemunis et al. [16] predicts permanent deformations due to a drained cyclic loading with many small cycles (i.e. N≥103 cycles with strain amplitudes εampl≤10−3). The strain amplitude is the most important influencing parameter of the rate of strai...
Saved in:
Published in: | Soil dynamics and earthquake engineering (1984) Vol. 70; pp. 118 - 132 |
---|---|
Main Authors: | , , |
Format: | Journal Article |
Language: | English |
Published: |
Elsevier Ltd
01-03-2015
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The high-cycle accumulation (HCA) model proposed by Niemunis et al. [16] predicts permanent deformations due to a drained cyclic loading with many small cycles (i.e. N≥103 cycles with strain amplitudes εampl≤10−3). The strain amplitude is the most important influencing parameter of the rate of strain accumulation ε̇acc. Based on tests on a medium coarse sand, a square relationship ε̇acc~(εampl)2 has been used in the HCA model so far. The new test results presented in this paper indicate, however, that the exponent of the amplitude-dependence may vary between 1.3 and 2.4, depending on the tested material. This comes out of 150 drained cyclic triaxial tests with 105 load cycles performed on 14 clean quartz sands with specially mixed grain size distribution curves. Consequently, an additional material constant Campl has been introduced into the HCA model describing the amplitude dependence according to ε̇acc~(εampl)Campl. The additional parameter requires a revision of the simplified calibration procedure proposed by Wichtmann et al. [24] which uses correlations between the HCA model parameters and granulometric (d50, Cu) or index properties (emin). Furthermore, the new cyclic test data reveal that the existing correlations are inappropriate for well-graded granular materials (Cu≥5). Enhanced correlations suitable also for more well-graded sands are proposed in the paper. The possible error of a HCA model prediction with parameters fully or partly determined from the correlations is discussed.
•Results from 150 drained cyclic triaxial tests with 105 cycles on 14 sands are presented.•The amplitude function of the HCA model has been revised introducing an additional material constant.•The parameters of the revised HCA model have been calibrated for 22 sands.•A simplified calibration procedure for the HCA model has been revised.•The new correlations deliver a more accurate prediction for well-graded granular materials. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0267-7261 1879-341X |