Search Results - "von Samson, P."
-
1
Thoracoabdominal Aortic Aneurysm Repair: Interplay of Spinal Cord Protecting Modalities
Published in European journal of vascular and endovascular surgery (01-12-2005)“…The purpose of this study was to assess the complementary use of different methods of measuring spinal cord perfusion during thoracoabdominal aortic surgery…”
Get full text
Journal Article -
2
Evaluation of three different measurement methods for dural ectasia in Marfan syndrome
Published in Clinical radiology (01-11-2006)“…Dural ectasia is a major diagnostic criterion for Marfan syndrome using the Ghent nosology. Our aim was to evaluate the efficacy of three different…”
Get full text
Journal Article -
3
Efficacy and frequency of cerebrospinal fluid drainage in operative management of thoracoabdominal aortic aneurysms
Published in The Thoracic and cardiovascular surgeon (01-03-2007)“…Paraplegia remains the most dreaded complication following thoracoabdominal aortic repair. We investigated the efficacy of cerebrospinal fluid drainage as a…”
Get more information
Journal Article -
4
-
5
(1073) Prolonged Bridging to Transplantation with Impella 5.5
Published in The Journal of heart and lung transplantation (01-04-2023)“…The Impella 5.5 (Abiomed, Danvers, MA) was introduced with the purpose to provide left ventricular hemodynamic support up to 30 days. However, in Germany,…”
Get full text
Journal Article -
6
(1074) Serial Assessment of Bronchial Anastomoses by Endobronchial Ultrasonography for Follow-Up in Lung Transplant Recipients
Published in The Journal of heart and lung transplantation (01-04-2023)“…Endobronchial ultrasonography (EBUS) is an adequate tool to analyze the bronchial structure, visualize the tracheobronchial wall invasion by intrathoracic…”
Get full text
Journal Article -
7
Minimal-Invasive LVAD Implantation, Is It Safe or Even Better?
Published in The Journal of heart and lung transplantation (01-04-2013)“…Purpose The rotary blood pump (HVAD) from HeartWare is an established left ventricular assist device and usually implanted via sternotomy. To reduce the…”
Get full text
Journal Article -
8
Improved spinal cord perfusion during thoracoabdominal aortic repair
Published in The Thoracic and cardiovascular surgeon (01-04-2005)“…The study's aim is to evaluate whether intraoperative neurophysiological monitoring with transcranial motor-evoked potentials (tcMEP) permits early recognition…”
Get more information
Journal Article -
9
Actual management of patients with familial ascending aortic aneurysms and type-A aortic dissections
Published in The Thoracic and cardiovascular surgeon (01-02-2007)“…There are few families with the diagnosis of ascending aortic aneurysm and acute type-A aortic dissection inherited as an autosomal-dominant disorder in the…”
Get more information
Journal Article -
10
Development of a special balloon occlusion device to prevent adverse events in high-risk patients during open aortic surgery
Published in European surgical research (01-07-2005)“…To prevent clamp injury that may occur during aortic surgery, we aimed to develop a special balloon occlusion (BO) device to lower the thromboembolic risk in…”
Get more information
Journal Article -
11
Sonic hedgehog myocardial gene therapy: tissue repair through transient reconstitution of embryonic signaling
Published in Nature medicine (01-11-2005)“…Sonic hedgehog (Shh) is a crucial regulator of organ development during embryogenesis. We investigated whether intramyocardial gene transfer of naked DNA…”
Get full text
Journal Article -
12
Synergistic effect of bone marrow mobilization and vascular endothelial growth factor-2 gene therapy in myocardial ischemia
Published in Circulation (New York, N.Y.) (14-09-2004)“…We performed a series of investigations to test the hypothesis that combining angiogenic gene therapy and cytokine (CK)-induced endothelial progenitor cell…”
Get full text
Journal Article -
13
Percutaneous aortic valve replacement: An experimental study. I. Studies on implantation
Published in The Journal of thoracic and cardiovascular surgery (01-04-2002)“…Objective: The purpose of this preliminary study was to devise a new surgical procedure for minimally invasive aortic valve implantation with a transluminal…”
Get full text
Journal Article -
14
Entwicklung eines neuen Ballonokklusions-Device alternativ zur Gefäßklemme bei offenen Eingriffen an der Aorta
Published in Zeitschrift für Herz-, Thorax- und Gefässchirurgie (01-12-2005)“…ZusammenfassungHintergrundSchwere atherosklerotische Veränderungen der Aorta und anderer großer Gefäße stellen eine besondere Herausforderung für den…”
Get full text
Journal Article -
15
Stem cell research and cell transplantation for myocardial regeneration
Published in European journal of cardio-thoracic surgery (01-08-2005)“…Several human organs are not capable of functional regeneration following a tissue defect and react with scar formation. In stem cell transplantation,…”
Get full text
Journal Article -
16
Neurophysiological monitoring during thoracoabdominal aortic endovascular stent graft implantation
Published in European journal of cardio-thoracic surgery (01-03-2006)“…Objective: The aim of this study was to evaluate the benefit of neurophysiological monitoring during thoracic and thoracoabdominal endovascular stent graft…”
Get full text
Journal Article -
17
Comparison of protein with DNA therapy for chronic myocardial ischemia using fibroblast growth factor-2
Published in European journal of cardio-thoracic surgery (01-12-2002)“…Objective: Treatment of coronary disease by growth factors has become an increasingly used strategy for otherwise untreatable patients and is subject to a…”
Get full text
Journal Article -
18
Setup of neurophysiological monitoring with tcMEP/SSEP during thoracoabdominal aneurysm repair
Published in The Thoracic and cardiovascular surgeon (01-02-2005)“…The article describes a procedure for the intraoperative neurophysiological placement of electrodes to control the spinal cord function during thoracoabdominal…”
Get more information
Journal Article -
19
The combined use of transmyocardial laser revascularization (TMLR) and fibroblastic growth factor (FGF-2) enhances perfusion and regional contractility in chronically ischemic porcine hearts
Published in European journal of cardio-thoracic surgery (01-11-2002)“…Objective: The purpose of this study was to determine the combined effect of transmyocardial laser revascularization (TMLR) and recombinant human basic…”
Get full text
Journal Article Conference Proceeding -
20
Evaluation of the indirect revascularization method after 3 months chronic myocardial ischemia
Published in European journal of cardio-thoracic surgery (01-07-2000)“…Objective: The long-term effectiveness of transmyocardial laser revascularization (TMLR) was evaluated in the setting of a severe left anterior descending…”
Get full text
Journal Article Conference Proceeding