Search Results - "van den Brom, H. E"

Refine Results
  1. 1

    Formation and manipulation of a metallic wire of single gold atoms by van Ruitenbeek, J. M, Yanson, A. I, Bollinger, G. Rubio, van den Brom, H. E, Agraït, N

    Published in Nature (London) (22-10-1998)
    “…The continuing miniaturization of microelectronics raises the prospect of nanometre-scale devices with mechanical and electrical properties that are…”
    Get full text
    Journal Article
  2. 2
  3. 3

    Characterization of individual conductance steps in metallic quantum point contacts by Brom, H.E.van den, Yanson, A.I., Ruitenbeek, J.M.van

    Published in Physica. B, Condensed matter (01-07-1998)
    “…The properties of a large number of individual steps in the conductance of atom-size contacts as a function of cross-section have been investigated. The…”
    Get full text
    Journal Article
  4. 4

    Power Quality Measurements in a Low-Voltage DC Microgrid in an Open Parking Garage by van den Brom, H. E., van Leeuwen, R., Warmerdam, J. M., Schaacke, R.

    “…Low-voltage DC microgrids are becoming more widely acknowledged as a viable option as local extensions of the conventional AC distribution grid. Consequently,…”
    Get full text
    Conference Proceeding
  5. 5

    Development of a wide-range sampling impedance ratio bridge by Houtzager, E., van den Brom, H. E., Dierikx, E.

    “…This paper describes an automated high-accuracy impedance bridge for the comparison of resistors, inductors or capacitors in the range between 1 mΩ and 100 MΩ…”
    Get full text
    Conference Proceeding Journal Article
  6. 6

    Smart grid power quality and stability measurements in Europe by Wright, P. S., Rietveld, G., van den Brom, H. E., Crotti, G., Braun, J. P.

    “…Significant scientific progress has been achieved in the first 18 months of an EU funded project on metrology in support of smart electrical grids. In this…”
    Get full text
    Conference Proceeding Journal Article
  7. 7

    Design of a non-invasive current sensor for application on high voltage lines by Houtzager, E., Rietveld, G., Dessens, J., Heemskerk, M., van den Brom, H. E.

    “…This paper describes the design and construction of an openable core current transformer (CT) to be used on high-voltage lines or busbars. The current sensor…”
    Get full text
    Conference Proceeding Journal Article
  8. 8

    Accurate subpicoampere current source based on a differentiating capacitor with software-controlled nonlinearity compensation by van den Brom, H.E., de la Court, P., Rietveld, G.

    “…A high accuracy current source has been developed for the generation of very small currents (below 200 pA) based on applying a linear voltage ramp to a…”
    Get full text
    Journal Article
  9. 9

    Smart grid power quality and stability measurements in Europe by Wright, P. S., Braun, J. P., Rietveld, G., van den Brom, H. E., Crotti, G.

    “…A description is given of a new EU funded project on metrology in support of smart electrical grids. This project is a partnership of 14 EU NMIs and two…”
    Get full text
    Conference Proceeding Journal Article
  10. 10
  11. 11

    Realization of a quantum standard for AC voltage: overview of a European research project by Chevtchenko, O.A., van den Brom, H.E., Houtzager, E., Behr, R., Kohlmann, J., Williams, J.M., Janssen, T.J.B.M., Palafox, L., Humphreys, D.A., Piquemal, F., Djordjevic, S., Monnoye, O., Poletaeff, A., Lapuh, R., Rydler, K.-E., Eklund, G.

    “…The European Josephson arbitrary waveform synthesizer (JAWS) project addresses the lack of instrumentation and knowledge for accurate and traceable measurement…”
    Get full text
    Journal Article
  12. 12

    Three-phase state estimation in the medium-voltage network with aggregated smart meter data by Ni, F., Nguyen, P.H., Cobben, J.F.G., Van den Brom, H.E., Zhao, D.

    “…•A new method to aggregate data from smart meters on the LV feeders is proposed.•Uncertainties associated with the aggregated smart meter data are…”
    Get full text
    Journal Article
  13. 13

    Online Estimation of Cable Harmonic Impedance in Low-Voltage Distribution Systems by Babaev, Stanislav, Cobben, Sjef, Cuk, Vladimir, van den Brom, Helko

    “…Incorrect values of cable harmonic impedance can lead to wrong conclusions when assessing an impact of current distortion on the power network. A theoretical…”
    Get full text
    Journal Article
  14. 14
  15. 15

    Switching Sampling Power Meter for Frequencies Up to 1 MHz by Houtzager, E., Rietveld, G., van den Brom, H. E.

    “…This paper describes a power measurement setup that is able to measure power up to the MHz region. The setup consists of a commercial digitizer together with a…”
    Get full text
    Journal Article
  16. 16

    Measurement Methods and Procedures for Assessing Accuracy of Instrument Transformers for Power Quality Measurements by Crotti, G., van den Brom, H.E., Mohns, E., Tinarelli, R., Luiso, M., Styblikova, R., Agazar, M, Cayci, H., Mazza, P., Meyer, J., Almutairi, M.

    “…Instrument transformers (ITs) are vital components of power quality (PQ) measurement systems in electrical transmission and distribution grids. Whereas…”
    Get full text
    Conference Proceeding
  17. 17

    High-Current CT Calibration Using a Sampling Current Ratio Bridge by Rietveld, G., Jol, L., van den Brom, H. E., So, E.

    “…A measurement setup is developed for the accurate ratio measurement of ac current transformers (CTs) for primary currents up to 5 kA. A unique property of the…”
    Get full text
    Journal Article
  18. 18
  19. 19
  20. 20

    Evaluation of EMI Effects on Static Electricity Meters by Wright, P.S., Rietveld, G., Leferink, F., Van den Brom, H.E., Alonso, F.R.I, Braun, J.P., Ellingsberg, K., Pous, M., Svoboda, M.

    “…Recent studies involving large errors in static electricity meters when exposed to step changes in the current waveform are reviewed. Triggered by these…”
    Get full text
    Conference Proceeding