Search Results - "da Cruz, P.A.L."
-
1
Rapid and accurate assessment of the activity measurements in Brazilian hospitals and clinics
Published in Applied radiation and isotopes (01-04-2018)“…Traceability in Nuclear Medicine Service (NMS) measurements was checked by the Institute of Radioprotection and Dosimetry (IRD) through the Institute of Energy…”
Get full text
Journal Article -
2
Standardization of 223Ra by live-time anticoincidence counting and gamma-ray emission determination
Published in Applied radiation and isotopes (01-04-2021)“…From a commercial supplier, three independent lots of an aqueous solution containing 223Ra in equilibrium with its deteriorating progeny were considered for…”
Get full text
Journal Article -
3
Measurement of the absolute gamma emission intensities from the decay of Th-229 in equilibrium with progeny
Published in Applied radiation and isotopes (01-12-2020)“…There are few long-lived radionuclides yielding high intensity gamma-rays emission with energies ranging from 100 keV to 500 keV that can be applied as…”
Get full text
Journal Article -
4
Results of an international comparison of activity measurements of $^{68}$Ge
Published in Applied radiation and isotopes (01-04-2018)“…An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the…”
Get full text
Journal Article -
5
Application of the sum-peak method to activity standardizations of 152 Eu sources in LNMRI (BR)
Published in Applied radiation and isotopes (01-04-2018)“…The sum-peak method, an absolute measurement technique that uses coincidence counting and γ-ray spectrometry, was applied to activity standardization of Eu…”
Get full text
Journal Article -
6
Application of the sum-peak method to activity standardizations of 152Eu sources in LNMRI (BR)
Published in Applied radiation and isotopes (01-04-2018)“…The sum-peak method, an absolute measurement technique that uses coincidence counting and γ-ray spectrometry, was applied to activity standardization of 152Eu…”
Get full text
Journal Article -
7
68(Ge+Ga) activity standardization by 4πβ(LS)-γ(NaI(Tl)) anticoincidence counting measurements
Published in Applied radiation and isotopes (01-04-2018)“…In this work, a 68(Ge+Ga) solution has been standardized at the National Institute of Ionizing Radiation Metrology (LNMRI), in Brazil, in the frame of an…”
Get full text
Journal Article -
8
Results of an international comparison of activity measurements of 68Ge
Published in Applied radiation and isotopes (01-04-2018)“…An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the…”
Get full text
Journal Article