Search Results - "Zhu, Peiping"
-
1
A method for material decomposition and quantification with grating based phase CT
Published in PloS one (22-01-2021)“…Material decomposition (MD) is an important application of computer tomography (CT). For phase contrast imaging, conventional MD methods are categorized into…”
Get full text
Journal Article -
2
Low-dose, simple, and fast grating-based X-ray phase-contrast imaging
Published in Proceedings of the National Academy of Sciences - PNAS (03-08-2010)“…Phase sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging and therefore new and otherwise…”
Get full text
Journal Article -
3
3D configuration of mandibles and controlling muscles in rove beetles based on micro-CT technique
Published in Analytical and bioanalytical chemistry (01-08-2011)“…X-ray micro-CT is a powerful tool to visualize without damage details of the inner structures of beetles, the largest order of insects with a hard external…”
Get full text
Journal Article -
4
Phase retrieval using polychromatic illumination for transmission X-ray microscopy
Published in Optics express (17-01-2011)“…An alternative method for quantitative phase retrieval in a transmission X-ray microscope system at sub-50-nm resolution is presented. As an alternative to…”
Get full text
Journal Article -
5
Fast X-Ray Phase-Contrast Imaging Using High Resolution Detector
Published in IEEE transactions on nuclear science (01-06-2009)“…X-ray phase-contrast imaging is a potential nondestructive testing and diagnostic technology in medicine, biology and materials science. It provides high…”
Get full text
Journal Article -
6
Effect of particle-size selectivity on quantitative X-ray dark-field computed tomography using a grating interferometer
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-08-2017)“…According to the conclusion of Khelashvili et al. [Phys. Med. Biol. 51, 221 (2006)], the minus logarithm of the visibility ratio fulfills the line integral…”
Get full text
Journal Article -
7
Advantages of intermediate X-ray energies in Zernike phase contrast X-ray microscopy
Published in Biotechnology advances (01-05-2013)“…Understanding the hierarchical organizations of molecules and organelles within the interior of large eukaryotic cells is a challenge of fundamental interest…”
Get full text
Journal Article Conference Proceeding -
8
Experimental exploration of mouse kidney imaging with the SR PCI technology
Published in Bio-medical materials and engineering (2014)“…This paper explores mouse kidney imaging with diffraction enhanced imaging (DEI) and inline outline X-ray imaging (IOXI) technology, and evaluates latent value…”
Get more information
Journal Article -
9
Synchrotron radiation topography study of temperature-induced phase transformation in unpoled 0.92Pb (Zn1/3Nb2/3)O3-0.08PbTiO3 crystals
Published in Solid state communications (01-10-2008)Get full text
Journal Article -
10
Phase retrieval from a single near-field diffraction pattern with a large Fresnel number
Published in Journal of the Optical Society of America. A, Optics, image science, and vision (01-11-2008)“…A new method of phase retrieval from a single near-field diffraction image with a large Fresnel number is presented and discussed. This method requires only…”
Get more information
Journal Article -
11
Experimental and theoretical investigations of diffraction enhanced imaging
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2007)“…This contribution investigates the effect on the imaging contrast of the small angle scattering and of the rocking curve in the entire angular range. We show…”
Get full text
Journal Article -
12
One-Step Method for Material Quantitation Using In-Line Tomography With Single Scanning
Published in IEEE transactions on biomedical engineering (01-01-2023)“…Objective: Quantitative technique based on In-line phase-contrast computed tomography with single scanning attracts more attention in application due to the…”
Get full text
Journal Article -
13
Zone plate-based full-field transmission X-ray microscopy beamline design at nearly diffraction-limited synchrotron radiation facility
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-03-2021)“…With the development of full-field transmission X-ray microscopy (TXM) for research in biology, life science, material science and physics, zone plate-based…”
Get full text
Journal Article -
14
Dual phase grating based X-ray differential phase contrast imaging with source grating: theory and validation
Published in Optics express (30-03-2020)“…In this work, we developed a new theoretical framework using wave optics to explain the working mechanism of the grating based X-ray differential phase…”
Get full text
Journal Article -
15
Ultra-thin freestanding diamond window for soft X-ray optics
Published in Diamond and related materials (01-03-2003)“…In this paper we reported the fabrication of the ultra-thin freestanding diamond windows for soft X-ray optics using hot filament CVD method. The diamond film…”
Get full text
Journal Article Conference Proceeding -
16
Generalized reverse projection method for grating‐based phase tomography
Published in Journal of synchrotron radiation (01-05-2021)“…The reverse projection protocol results in fast phase‐contrast imaging thanks to its compatibility with conventional computed‐tomography scanning. Many…”
Get full text
Journal Article -
17
The design and implementation of the Examination System Based on the Word — VBA
Published in 2015 7th International Conference on Modelling, Identification and Control (ICMIC) (01-12-2015)“…The Examination System Based on the Word-VBA is developed based on Word software platform and uses the VBA programming language embedded in Word platform…”
Get full text
Conference Proceeding -
18
A 30 nm-resolution hard X-ray microscope with X-ray fluorescence mapping capability at BSRF
Published in Journal of synchrotron radiation (01-11-2012)“…A full‐field transmission X‐ray microscope (TXM) operating continuously from 5 keV to 12 keV with fluorescence mapping capability has been designed and…”
Get full text
Journal Article -
19
Analysis of an x-ray mirror made from piezoelectric bimorph
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-07-2017)“…Theoretical analysis of the mechanical behavior of an x-ray mirror made from piezoelectric bimorph is presented. A complete two-dimensional relationship…”
Get full text
Journal Article -
20
A theoretically exact reconstruction algorithm for helical cone-beam differential phase-contrast computed tomography
Published in Physics in medicine & biology (21-08-2013)“…Differential phase-contrast computed tomography (DPC-CT) reconstruction problems are usually solved by using parallel-, fan- or cone-beam algorithms. For…”
Get more information
Journal Article