Search Results - "Zhang, Yan J."
-
1
Recommendations for Validation of LC-MS/MS Bioanalytical Methods for Protein Biotherapeutics
Published in The AAPS journal (01-01-2015)“…ABSTRACT This paper represents the consensus views of a cross-section of companies and organizations from the USA and Canada regarding the validation and…”
Get full text
Journal Article -
2
Eliminating Preparation of Multisample External Calibration Curves and Dilution of Study Samples Using the Multiple Isotopologue Reaction Monitoring (MIRM) Technique in Quantitative LC-MS/MS Bioanalysis
Published in Analytical chemistry (Washington) (02-07-2019)“…Preparation of multisample external calibration curves and dilution of study samples are critical steps in bioanalytical sample processing for quantitative…”
Get full text
Journal Article -
3
In-Sample Calibration Curve Using Multiple Isotopologue Reaction Monitoring of a Stable Isotopically Labeled Analyte for Instant LC-MS/MS Bioanalysis and Quantitative Proteomics
Published in Analytical chemistry (Washington) (05-02-2019)“…A novel methodology of in-sample calibration curves (ISCC) using multiple isotopologue reaction monitoring (MIRM) of multiple naturally occurring isotopologue…”
Get full text
Journal Article -
4
Antipeptide Immunocapture with In-Sample Calibration Curve Strategy for Sensitive and Robust LC-MS/MS Bioanalysis of Clinical Protein Biomarkers in Formalin-Fixed Paraffin-Embedded Tumor Tissues
Published in Analytical chemistry (Washington) (03-11-2020)“…Despite huge promises, bioanalysis of protein biomarkers in formalin-fixed paraffin-embedded (FFPE) tissues by liquid chromatography-tandem mass spectrometry…”
Get full text
Journal Article -
5
Fit-for-purpose protein biomarker assay validation strategies using hybrid immunocapture-liquid chromatography-tandem-mass spectrometry platform: Quantitative analysis of total soluble cluster of differentiation 73
Published in Analytica chimica acta (22-08-2020)“…In recent years, biomarkers have played more extensive roles as indicators of disease progression, safety, and drug efficacy. Targeted quantitative analysis of…”
Get full text
Journal Article -
6
Technologies and strategies for bioanalysis of biopharmaceuticals
Published in Bioanalysis (01-09-2017)Get full text
Journal Article -
7
Identification of Dynein Heavy Chain 7 as an Inner Arm Component of Human Cilia That Is Synthesized but Not Assembled in a Case of Primary Ciliary Dyskinesia
Published in The Journal of biological chemistry (17-05-2002)“…Although the basic structure of the axoneme has been highly conserved throughout evolution, the varied functions of specialized axonemes require differences in…”
Get full text
Journal Article -
8
Determination of Real Time in Vivo Drug Receptor Occupancy for a Covalent Binding Drug as a Clinical Pharmacodynamic Biomarker by Immunocapture-LC-MS/MS
Published in Analytical chemistry (Washington) (02-07-2019)“…We report a novel immunocapture (IC)-LC-MS/MS methodology to directly measure real time in vivo receptor occupancy (RO) for a covalent binding drug in blood…”
Get full text
Journal Article -
9
A multiplexed immunocapture liquid chromatography tandem mass spectrometry assay for the simultaneous measurement of myostatin and GDF-11 in rat serum using an automated sample preparation platform
Published in Analytica chimica acta (01-08-2017)“…Myostatin, also known as growth differentiation factor 8 (GDF-8), is a protein acting as a negative regulator in skeletal muscle growth. Inhibition of…”
Get full text
Journal Article -
10
Characterization of labeled reagents in ligand-binding assays by a surface plasmon resonance biosensor
Published in Bioanalysis (01-01-2017)“…Ligand-binding assay (LBA) reagent labeling may change the binding characteristics of the reagent to its target and degrade its performance in LBAs. A surface…”
Get full text
Journal Article -
11
Surface plasmon resonance as a tool for ligand-binding assay reagent characterization in bioanalysis of biotherapeutics
Published in Bioanalysis (01-04-2018)“…Ligand-binding assay (LBA) performance depends on quality reagents. Strategic reagent screening and characterization is critical to LBA development,…”
Get full text
Journal Article -
12
The integration of ligand binding and LC-MS-based assays into bioanalytical strategies for protein analysis
Published in Bioanalysis (01-01-2014)“…Both LBAs and LC-MS-based assays are reviewed and summarized for applications in quantitative protein analysis. A strategy for platform selection is proposed…”
Get full text
Journal Article -
13
Overview on biotherapeutic proteins: impact on bioanalysis
Published in Bioanalysis (2016)“…This article provides an overview of the information and factors relevant to designing bioanalytical strategies in support of in vivo nonclinical and clinical…”
Get full text
Journal Article -
14
LC-MS/MS bioanalysis of plasma 1, 14-tetradecanedioic acid and 1, 16-hexadecanedioic acid as candidate biomarkers for organic anion-transporting polypeptide mediated drug-drug interactions
Published in Bioanalysis (01-09-2018)“…A robust LC-MS/MS assay was developed to quantify endogenous 1, 14-tetradecanedioic acid (TDA) and 1, 16-hexadecanedioic acid (HDA) in human plasma as…”
Get full text
Journal Article -
15
Activation of Toll-like receptor 2 on human tracheobronchial epithelial cells induces the antimicrobial peptide human beta defensin-2
Published in The Journal of immunology (1950) (15-12-2003)“…As pattern recognition receptors capable of eliciting responses to a diverse array of microbial products, Toll-like receptors (TLRs) participate in the…”
Get full text
Journal Article -
16
Quantitation of a PEGylated protein in monkey serum by UHPLC-HRMS using a surrogate disulfide-containing peptide: A new approach to bioanalysis and in vivo stability evaluation of disulfide-rich protein therapeutics
Published in Analytica chimica acta (15-04-2016)“…To quantify a therapeutic PEGylated protein in monkey serum as well as to monitor its potential in vivo instability and methionine oxidation, a novel ultra…”
Get full text
Journal Article -
17
Rapid development of multiple 'fit-for-purpose' assays on an automatic microfluidic system using a streamlined process in support of early biotherapeutics discovery programs
Published in Bioanalysis (01-07-2013)“…With a rapid increase in the number of novel biotherapeutic programs in the pipelines, efficient development of ligand-binding assays for PK and PD studies in…”
Get full text
Journal Article -
18
A generic template for automated bioanalytical ligand-binding assays using modular robotic scripts in support of discovery biotherapeutic programs
Published in Bioanalysis (01-07-2013)“…Sample dilution and reagent pipetting are time-consuming steps in ligand-binding assays (LBAs). Traditional automation-assisted LBAs use assay-specific scripts…”
Get full text
Journal Article -
19
Electrochemiluminescence in bioanalysis
Published in Bioanalysis (01-08-2009)“…The discovery of electrochemiluminescence (ECL) and its development as a means of detection is truly a success story. Although studies describing ECL were…”
Get more information
Journal Article -
20
Immunoassay-based measurement of clinical biomarkers for monitoring changes in nasal cavity
Published in Journal of pharmaceutical and biomedical analysis (05-12-2009)“…Many drugs for treatment of allergies, migraine headaches, inflammation, and other indications are administered into the nasal cavity providing access to the…”
Get full text
Journal Article