Search Results - "Zappe, H"

Refine Results
  1. 1

    Smart artificial muscle actuators: Liquid crystal elastomers with integrated temperature feedback by Petsch, S., Rix, R., Khatri, B., Schuhladen, S., Müller, P., Zentel, R., Zappe, H.

    Published in Sensors and actuators. A. Physical. (15-07-2015)
    “…•Thermotropic liquid crystal elastomer actuators. Integrated deformable wiring (Pt heater and sensor).•Temperature sensors allows for closed loop control.•Fast…”
    Get full text
    Journal Article
  2. 2

    A two-step Fabry-Perot filter array in mid-infrared wavelength range for integration with photochemical microreactors by Wang, Z., Cu-Nguyen, P-H., Zappe, H.

    Published in Sensors and actuators. A. Physical. (15-08-2020)
    “…[Display omitted] •An mid-infrared spectral analysis system with no moving parts.•Fabry-Perot filter array provides both spectral and spatial…”
    Get full text
    Journal Article
  3. 3

    Time of administration important? Morning versus evening dosing of valsartan by Zappe, Dion H, Crikelair, Nora, Kandra, Albert, Palatini, Paolo

    Published in Journal of hypertension (01-02-2015)
    “…OBJECTIVE:Studies suggest that bedtime dosing of an angiotensin-converting enzyme (ACE)-inhibitor or angiotensin receptor blocker shows a more sustained and…”
    Get full text
    Journal Article
  4. 4

    Ultrathin Alvarez lens system actuated by artificial muscles by Petsch, S, Grewe, A, Köbele, L, Sinzinger, S, Zappe, H

    “…A key feature of Alvarez lenses is that they may be tuned in focal length using lateral rather than axial translation, thus reducing the overall length of a…”
    Get more information
    Journal Article
  5. 5

    Jet printing of convex and concave polymer micro-lenses by Blattmann, M, Ocker, M, Zappe, H, Seifert, A

    Published in Optics express (21-09-2015)
    “…We describe a novel approach for fabricating customized convex as well as concave micro-lenses using substrates with sophisticated pinning architecture and…”
    Get full text
    Journal Article
  6. 6

    Tunable Pneumatic Microoptics by Werber, A., Zappe, H.

    Published in Journal of microelectromechanical systems (01-10-2008)
    “…A new class of tunable and actuated microoptical devices is presented: pneumatic microoptics. Using microelectromechanical system fabrication technology…”
    Get full text
    Journal Article
  7. 7

    PEGylation of cyanovirin–N, an entry inhibitor of HIV by Zappe, H., Snell, M.E., Bossard, M.J.

    Published in Advanced drug delivery reviews (03-01-2008)
    “…Cyanovirin–N (CV–N) is a potent inhibitor of human immunodeficiency virus and many other viruses. It has a high potential for use as a systemic compound to…”
    Get full text
    Journal Article
  8. 8

    Implantable accelerometer system for the determination of blood pressure using reflected wave transit time by Theodor, M., Fiala, J., Ruh, D., Förster, K., Heilmann, C., Beyersdorf, F., Manoli, Y., Zappe, H., Seifert, A.

    Published in Sensors and actuators. A. Physical. (01-02-2014)
    “…•Arterial movement tracked by implantable accelerometer.•Blood pressure determination with high accuracy.•Implantable system for long-term monitoring. A sensor…”
    Get full text
    Journal Article
  9. 9
  10. 10

    Electrowetting for Tunable Microoptics by Krogmann, F., Monch, W., Zappe, H.

    Published in Journal of microelectromechanical systems (01-12-2008)
    “…The design, fabrication, and optical properties of tunable liquid microoptical components based on electrowetting are presented. Two optical microsystems are…”
    Get full text
    Journal Article
  11. 11

    Effects of Sacubitril/Valsartan Versus Olmesartan on Central Hemodynamics in the Elderly With Systolic Hypertension: The PARAMETER Study by Williams, Bryan, Cockcroft, John R, Kario, Kazuomi, Zappe, Dion H, Brunel, Patrick C, Wang, Qian, Guo, Weinong

    Published in Hypertension (Dallas, Tex. 1979) (01-03-2017)
    “…Effective treatment of systolic hypertension in elderly patients remains a major therapeutic challenge. A multicenter, double-blind, randomized controlled…”
    Get full text
    Journal Article
  12. 12

    Deformable Polymer Adaptive Optical Mirrors by Friese, C., Zappe, H.

    Published in Journal of microelectromechanical systems (01-02-2008)
    “…The design, fabrication, and evaluation of deformable polymer-based micromirror devices for adaptive optic applications are described. For the mirror…”
    Get full text
    Journal Article
  13. 13

    Application of non-invasive central aortic pressure assessment in clinical trials: Clinical experience and value by Williams, Bryan, Brunel, Patrick, Lacy, Peter S, Baschiera, Fabio, Zappe, Dion H, Kario, Kazuomi, Cockcroft, John

    Published in Artery research (01-03-2017)
    “…Abstract Pressure measured with a cuff and sphygmomanometer in the brachial artery is accepted as an important predictor of future cardiovascular (CV) events…”
    Get full text
    Journal Article
  14. 14

    Thermal and Optical Characterization of Silicon-Based Tunable Optical Thin-Film Filters by Hohlfeld, D., Zappe, H.

    Published in Journal of microelectromechanical systems (01-06-2007)
    “…In this paper, we report on the successful fabrication and comprehensive optical and electrothermal characterization of a silicon-based tunable optical filter…”
    Get full text
    Journal Article
  15. 15

    Hypertension in Obese Zucker Rats: Role of Angiotensin II and Adrenergic Activity by Alonso-Galicia, Magdalena, Brands, Michael W, Zappe, Dion H, Hall, John E

    Published in Hypertension (Dallas, Tex. 1979) (01-12-1996)
    “…We designed our studies to determine whether blood pressure is elevated in obese Zucker rats compared with lean control rats and to test the importance of the…”
    Get full text
    Journal Article Conference Proceeding
  16. 16

    Cardiovascular outcomes at different on-treatment blood pressures in the hypertensive patients of the VALUE trial by Mancia, Giuseppe, Kjeldsen, Sverre E, Zappe, Dion H, Holzhauer, Björn, Hua, Tsushung A, Zanchetti, Alberto, Julius, Stevo, Weber, Michael A

    Published in European heart journal (21-03-2016)
    “…Recent hypertension guidelines recommend that also in high cardiovascular (CV) risk, hypertensive patients blood pressure (BP) is lowered to <140/90 mmHg as no…”
    Get full text
    Journal Article
  17. 17

    Development of an Implantable Pulse Oximeter by Reichelt, Stephan, Fiala, Jens, Werber, Armin, Forster, Katharina, Heilmann, Claudia, Klemm, Rolf, Zappe, Hans

    “…A long-term implantable photoplethysmographic sensor system is proposed. The system employs an elastic cuff which is directly wrapped around an arterial blood…”
    Get full text
    Journal Article
  18. 18

    Reconfigurable liquid micro-lenses with high positioning accuracy by Krogmann, F., Shaik, R., Lasinger, L., Mönch, W., Zappe, H.

    Published in Sensors and actuators. A. Physical. (02-05-2008)
    “…A new technique to improve the positioning accuracy of liquid droplets in electrowetting-on-dielectric applications is presented. The approach is based on a…”
    Get full text
    Journal Article
  19. 19

    Efficacy and Safety of Crystalline Valsartan/Sacubitril (LCZ696) Compared With Placebo and Combinations of Free Valsartan and Sacubitril in Patients With Systolic Hypertension: The RATIO Study by Izzo, Joseph L, Zappe, Dion H, Jia, Yan, Hafeez, Kudsia, Zhang, Jack

    Published in Journal of cardiovascular pharmacology (01-06-2017)
    “…We compared the systolic blood pressure (SBP)-lowering efficacy and safety of crystalline valsartan/sacubitril (LCZ696, an angiotensin receptor…”
    Get full text
    Journal Article
  20. 20

    A thermally tunable, silicon-based optical filter by Hohlfeld, D., Epmeier, M., Zappe, H.

    Published in Sensors and actuators. A, Physical (15-01-2003)
    “…A novel silicon MEMS-based concept for tunable optical filters used in wavelength-division multiplexing (WDM) systems is presented. Such a filter is essential…”
    Get full text
    Journal Article Conference Proceeding