Search Results - "Zagatto, E. A. G."

Refine Results
  1. 1

    Molecularly imprinted polymer as a solid phase extractor in flow analysis by Dias, A.C.B., Figueiredo, E.C., Grassi, V., Zagatto, E.A.G., Arruda, M.A.Z.

    Published in Talanta (Oxford) (15-09-2008)
    “…Molecularly imprinted polymers (MIPs) are novel alternative materials for solid phase extraction. Applications in flow analysis are recent and enhanced in-line…”
    Get full text
    Journal Article
  2. 2

    Zone trapping/merging zones in flow analysis: A novel approach for rapid assays involving relatively slow chemical reactions by Vida, Ana C.F., Sasaki, Milton K., Gomes, Taciana F., Silva, Claudineia R., Feres, Mário A., Zagatto, E.A.G.

    Published in Talanta (Oxford) (15-07-2011)
    “…A novel strategy for accomplishing zone trapping in flow analysis is proposed. The sample and the reagent solutions are simultaneously inserted into convergent…”
    Get full text
    Journal Article
  3. 3

    Chemiluminometric determination of ascorbic acid in pharmaceutical formulations exploiting photo-activation of GSH-capped CdTe quantum dots by Sasaki, M. K., Ribeiro, D. S. M., Frigerio, C., Prior, J. A. V., Santos, J. L. M., Zagatto, E. A. G.

    Published in Luminescence (Chichester, England) (01-11-2014)
    “…ABSTRACT An automated multi‐pumping flow system is proposed for the chemiluminometric determination of ascorbic acid in pharmaceutical formulations, relying on…”
    Get full text
    Journal Article
  4. 4

    Prior assay as an approach to flow titrations. Spectrophotometric determination of iron in alloys and ores by Honorato, Ricardo Saldanha, Zagatto, Elias Ayres G, Lima, Ricardo Alexandre C, Araújo, Mário César U

    Published in Analytica chimica acta (10-07-2000)
    “…In titrimetric procedures, the number of data points can be reduced when the analyte concentration is roughly known. This aspect is emphasised in automated…”
    Get full text
    Journal Article
  5. 5

    Multicommutation in flow analysis. II: Binary sampling for spectrophotometric determination of nickel, iron and chromium in steel alloys by MARTELLI, P. B, REIS, B. F, KRONKA, E. A. M, BERGAMIN F, H, KORN, M, ZAGATTO, E. A. G, LIMA, J. L. F. C, ARAUJO, A. N

    Published in Analytica chimica acta (09-06-1995)
    “…Multicommutation flow systems for the spectrophotometric determination of nickel, iron and chromium in acid solutions of steel alloys employing a binary…”
    Get full text
    Conference Proceeding Journal Article
  6. 6

    Terminology for analytical capillary electromigration techniques (IUPAC Recommendations 2003) by Riekkola, M.-L., Jönsson, J. Å., Smith, R. M.

    Published in Pure and applied chemistry (01-01-2004)
    “…This paper presents terms and definitions for capillary electromigration techniques for separation, qualitative and quantitative analysis and physico-chemical…”
    Get full text
    Journal Article
  7. 7

    Mixing chambers in flow analysis: A review by Zagatto, E. A. G., Carneiro, J. M. T., Vicente, S., Fortes, P. R., Santos, J. L. M., Lima, J. L. F. C.

    “…Inclusion of a mixing chamber in a flow system is critically rev—iewed in-relation to sample dilution, improvement of mixing conditions and exploitation of…”
    Get full text
    Journal Article
  8. 8

    A flow-batch titrator exploiting a one-dimensional optimisation algorithm for end point search by Honorato, Ricardo S., Araújo, Mário César U., Lima, Ricardo A.C., Zagatto, Elias A.G., Lapa, Rui A.S., Costa Lima, José L.F.

    Published in Analytica chimica acta (13-09-1999)
    “…A flow-batch hybrid system is proposed as a novel approach to automated titration. Sampling and signal processing are done as in usual flow systems, whereas…”
    Get full text
    Journal Article
  9. 9

    Anionic surfactants in acid media: a new cloud point extraction approach for the determination of polycyclic aromatic hydrocarbons in environmental samples by Sicilia, D, Rubio, S, Pérez-Bendito, D, Maniasso, N, Zagatto, E.A.G

    Published in Analytica chimica acta (14-06-1999)
    “…Anionic surfactants separate into two isotropic phases in an acid medium at room temperature and can be successfully used in the cloud point extraction…”
    Get full text
    Journal Article Conference Proceeding
  10. 10

    Spectrophotometric flow-batch determination of aluminum in plant tissues exploiting a feedback mechanism by Honorato, Ricardo S., Carneiro, Josiane M.T., Zagatto, Elias A.G.

    Published in Analytica chimica acta (24-08-2001)
    “…The feasibility of flow-batch systems to carry out procedures exploiting feedback mechanisms is discussed, and a flow-batch analyzer is proposed for…”
    Get full text
    Journal Article
  11. 11

    High-sensitivity methods for sequential injection determination of the main constituents of alloys by Dias, Ana Cristi B, Carneiro, Josiane M.T, Grassi, Viviane, Zagatto, Elias A.G

    Published in Analytica chimica acta (01-07-2004)
    “…A sequential injection system with spectrophotometric detection was proposed for the determination of copper, zinc and lead in brass. In view of the high…”
    Get full text
    Journal Article
  12. 12

    Multi-task flow system for potentiometric analysis : its application to the determination of vitamin B6 in pharmaceuticals by FERNANDES, R. N, SALES, M. G. F, REIS, B. F, ZAGATTO, E. A. G, ARAUJO, A. N, MONTENEGRO, M. C. B. S. M

    “…A flow set-up based on the sequential injection analysis concept was designed, aiming at increased automation and robustness of procedures related with…”
    Get full text
    Journal Article
  13. 13

    Evolution of the commutation concept associated with the development of flow analysis by Zagatto, Elias A.G, Reis, Boaventura F, Oliveira, Cláudio C, Sartini, Raquel P, Arruda, Marco Aurélio Z

    Published in Analytica chimica acta (01-11-1999)
    “…Evolution of the commutation concept has lead to the proposal and development of different generations of flow analyzers. Since the inception of the…”
    Get full text
    Journal Article Conference Proceeding
  14. 14

    Flow-injection spectrophotometric catalytic determination of manganese in plants exploiting the aerial oxidation of diphenyl carbazone by Maniasso, Nelson, Zagatto, Elias A.G

    Published in Analytica chimica acta (19-06-1998)
    “…The catalytic effect of Mn(II) on the aerial oxidation of diphenylcarbazone (DFC) becomes very pronounced in the presence of triethanolamine (TEA), whereas the…”
    Get full text
    Journal Article Conference Proceeding
  15. 15

    An automatic titrator based on a multicommutated unsegmented flow system: Its application to acid–base titrations by Almeida, Cristina M.N.V., Lapa, Rui A.S., Lima, José L.F.C., Zagatto, Elias A.G., Araújo, M.C.U.

    Published in Analytica chimica acta (29-02-2000)
    “…A continuous flow methodology to perform acid–base titrations is described. The titrations are carried out on a multicommutated flow system which simulates…”
    Get full text
    Journal Article
  16. 16

    Sampling strategies in sequential injection analysis: Exploiting the monosegmented-flow approach by Vieira, Jonas A, Raimundo, Jr, Ivo M, Reis, Boaventura F, Zagatto, Elias A.G, Lima, José L.F.C

    Published in Analytica chimica acta (19-06-1998)
    “…An evaluation of different sampling techniques employing sequential injection analysis (SIA) is described. The reaction between Fe(II) and 1,10-phenanthroline,…”
    Get full text
    Journal Article Conference Proceeding
  17. 17

    A multicommutated flow system with on-line compensation of the Schlieren effect applied to the spectrophotometric determination of pindolol by Lapa, Rui A.S, Lima, José L.F.C, Reis, Boaventura F, Santos, João L.M, Zagatto, Elias A.G

    Published in Analytica chimica acta (19-06-1998)
    “…A continuous flow methodology for the spectrophotometric determination of pindolol in pharmaceutical preparations following complexation with Fe(III) is…”
    Get full text
    Journal Article Conference Proceeding
  18. 18

    Spectrophotometric determination of total nitrogen in plant materials using a flow-injection system with an AgCl (s) reactor by Carneiro, Josiane M.T, Sartini, Raquel P, Zagatto, Elias A.G

    Published in Analytica chimica acta (10-07-2000)
    “…An improved flow-injection system with an AgCl (s) reactor is proposed for the spectrophotometric determination of total nitrogen in Kjeldahl digests of plant…”
    Get full text
    Journal Article
  19. 19

    Development of a potentiometric procedure for determination of glycerol and 2,3-butanediol in wine by sequential injection analysis by Luca, Gilmara C, Reis, Boaventura F, Zagatto, Elias A.G, Montenegro, Maria Conceição B.S.M, Araújo, Alberto N, Lima, José Luis F.C

    Published in Analytica chimica acta (19-06-1998)
    “…A sequential injection procedure with potentiometric detection for determination of glycerol and 2,3-butanediol in wine is described. The method was based on…”
    Get full text
    Journal Article Conference Proceeding
  20. 20

    A polyvalent flow injection system for multielemental spectrophotometric analysis of plant materials by Silva, F.V, Nogueira, A.R.A, Souza, G.B, Zagatto, E.A.G

    Published in Analytica chimica acta (31-08-1998)
    “…A polyvalent flow injection system consisting of a single manifold suitable to perform different determinations after only minor adaptations was conceived. Its…”
    Get full text
    Journal Article