요부 내측지 고주파 신경절리술 시행 시 유도침 경로를 따라 발생한 화상 -증례보고

Radiofrequency neurotomy of the lumbar medial branch, via a caudal approach, is a representative interventional procedure for lumbar zygapophysial joint pain, which can be performed more accurately and easily using a guide needle technique. We experienced a case of burn wound formation along the gui...

Full description

Saved in:
Bibliographic Details
Published in:The Korean journal of pain Vol. 19; no. 2; pp. 257 - 260
Main Authors: 윤홍준, 심재철, Youn, Hong Jun, Shim, Jae Chol
Format: Journal Article
Language:Korean
Published: 2006
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Radiofrequency neurotomy of the lumbar medial branch, via a caudal approach, is a representative interventional procedure for lumbar zygapophysial joint pain, which can be performed more accurately and easily using a guide needle technique. We experienced a case of burn wound formation along the guide needle trajectory, where heat conduction through the guide needle was suggested to have resulted in the burn wound.
Bibliography:KISTI1.1003/JNL.JAKO200610102404894