Search Results - "Yettram, A.L"
-
1
Stress and strain distribution within the intact femur: compression or bending?
Published in Medical engineering & physics (01-03-1996)“…The aim of this research was to test the hypothesis that the intact femur is loaded predominately in compression. The study was composed of two parts: a finite…”
Get full text
Journal Article -
2
Intramedullary femoral nails: one or two lag screws? A preliminary study
Published in Medical engineering & physics (01-11-2000)“…Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a…”
Get full text
Journal Article -
3
Cancellous bone stresses surrounding the femoral component of a hip prosthesis: an elastic-plastic finite element analysis
Published in Medical engineering & physics (01-10-1995)“…The cancellous bone stresses surrounding the femoral component of total hip replacement were investigated using the finite element method. Four versions of a…”
Get full text
Journal Article -
4
Finite element stress analysis of the crowns of normal and restored teeth
Published in Journal of dental research (01-11-1976)“…Stress distributions are presented for a normal and a restored mandibular second premolar under masticatory-type forces. These were obtained using the finite…”
Get more information
Journal Article -
5
Reactive force distributions for teeth when loaded singly and when used as fixed partial denture abutments
Published in The Journal of prosthetic dentistry (01-10-1979)“…1. A finite element model was devised to examine mechanical responses of the periodontium to loads applied to the model in vertical, oblique, and horizontal…”
Get more information
Journal Article -
6
Intramedullary nails with two lag screws
Published in Clinical biomechanics (Bristol) (01-06-2004)“…Objective. To investigate the structural integrity of intramedullary nails with two lag screws, and to give guidance to orthopaedic surgeons in the choice of…”
Get full text
Journal Article -
7
P038 The role of the cortical bone around the head of
Published in Journal of biomechanics (01-07-1998)Get full text
Journal Article -
8
Intramedullary nails: some design features of the distal end
Published in Medical engineering & physics (01-05-2004)Get full text
Journal Article -
9
Finite element analysis of a Gamma nail within a fractured femur
Published in Medical engineering & physics (01-11-1998)“…Failures of Gamma nails which treat unstable femoral fractures have been reported. In this paper, a finite element model to include a Gamma nail within a…”
Get full text
Journal Article -
10
Intramedullary nails: some design features of the distal end
Published in Medical engineering & physics (01-11-2003)“…Intramedullary nails are used to stabilise fractures of the proximal femur. The nail acts by transferring loads from the proximal fraction to the rest of the…”
Get full text
Journal Article -
11
The structural integrity of a gamma nail
Published in Journal of biomechanics (01-07-1998)Get full text
Journal Article -
12
Authors' response
Published in Medical engineering & physics (01-01-1997)Get full text
Journal Article -
13
An analytical method for the determination of along-fibre to cross-fibre elastic modulus ratio in ventricular myocardium — a feasibility study
Published in Medical engineering & physics (01-03-1998)“…The myocardium of the left ventricle of the heart is a fibrous structure, the fibres being wound helically anticlockwise on the epicardium and changing…”
Get full text
Journal Article -
14
The response of bone to external loading regimens
Published in Medical engineering & physics (1994)“…The results of Hert et al. have been re-examined using an external pin fixation technique involving New Zealand White rabbits. New bone formation was assessed…”
Get more information
Journal Article -
15
Is stem length important in uncemented endoprostheses?
Published in Medical engineering & physics (01-06-1995)“…In an uncemented total hip replacement where the femoral stem is thinner than the medullary canal it may be hypothesized that the distal portion of the stem…”
Get full text
Journal Article -
16
Finite element stress analysis of a class I amalgam restoration subjected to setting and thermal expansion
Published in Journal of dental research (01-05-1978)“…Stress analyses are presented for a second mandibular premolar with a class 1 amalgam restoration. The effects of amalgam setting and thermal expansions are…”
Get more information
Journal Article -
17
Effect of interface conditions on the behaviour of a Freeman hip endoprosthesis
Published in Journal of biomedical engineering (01-11-1989)“…The femoral element of a total hip replacement is a composite structure of two, or perhaps three, components--the endoprosthesis, the bone and, where present,…”
Get more information
Journal Article -
18
The forces acting on the human calcaneus
Published in Journal of biomedical engineering (01-01-1993)“…The forces acting on the human calcaneus are analysed for a static standing posture. An optimization procedure is invoked to solve the statically indeterminate…”
Get more information
Journal Article -
19
Biomechanics of the femoral component of total hip prostheses with particular reference to the stress in the bone-cement
Published in Journal of biomedical engineering (01-10-1979)“…Two-dimensional finite element analyses were used to determine the normal and shear stress distributions at the prostheses-cement and cement-bone interfaces in…”
Get more information
Journal Article -
20
An analytical investigation into possible mechanical causes of bone remodelling
Published in Journal of biomedical engineering (01-01-1979)“…Three-dimensional finite element analyses were carried out on idealisations of two situations where bone remodelling has been reported clinically viz. the…”
Get more information
Journal Article