Search Results - "Yeh, H.M."

Refine Results
  1. 1

    The influences of recycle on performance of baffled double-pass flat-plate solar air heaters with internal fins attached by Ho, C.D., Yeh, H.M., Cheng, T.W., Chen, T.C., Wang, R.C.

    Published in Applied energy (01-09-2009)
    “…A new device for inserting an absorber plate to divide a flat-plate channel into two parts with fins attached by baffles and external recycling at the ends is…”
    Get full text
    Journal Article
  2. 2

    Mass transfer for dialysis through parallel-flow double-pass rectangular membrane modules by Yeh, H.M., Chang, Y.H.

    Published in Journal of membrane science (01-09-2005)
    “…A study on membrane dialysis in parallel-plate rectangular mass exchangers was carried out under cocurrent-flow and countercurrent-flow operations. It was…”
    Get full text
    Journal Article
  3. 3

    Membrane ultrafiltration in a tubular module with a steel rod inserted concentrically for improved performance by Yeh, H.M., Chen, H.Y., Chen, K.T.

    Published in Journal of membrane science (15-04-2000)
    “…Rising fluid velocity in the tubular-membrane module by inserting concentrically a steel rod has two conflicting effects. One, the decrease in resistance to…”
    Get full text
    Journal Article
  4. 4

    Solvent extraction in multipass parallel-flow mass exchangers of microporous hollow-fiber modules by Yeh, H.M., Huang, C.M.

    Published in Journal of membrane science (14-07-1995)
    “…A study on solvent extraction in multipass microporous hollow-fiber modules has been carried out both theoretically and experimentally. It was found that mass…”
    Get full text
    Journal Article
  5. 5

    Membrane extraction through cross-flow rectangular modules by Yeh, H.M., Chen, Y.K.

    Published in Journal of membrane science (31-05-2000)
    “…The mass transfer for membrane extraction through a cross-flow parallel-plate module has been studied both theoretically and experimentally. Theoretical…”
    Get full text
    Journal Article
  6. 6

    Effect of recycle-barrier location on membrane extraction in a parallel-flow rectangular module with internal reflux by Yeh, H.M., Hung, F.C., Chen, C.H., Hung, C.R.

    Published in Chemical engineering science (2005)
    “…The influence of recycle-barrier location on membrane extraction through a parallel-flow rectangular module with internal reflux has been investigated. The…”
    Get full text
    Journal Article
  7. 7

    Numerical analysis of mass transfer in double-pass parallel-plate dialyzers with external recycle by Yeh, H.M.

    Published in Computers & chemical engineering (21-04-2009)
    “…The effect of external recycle on the performance of dialysis in double-pass rectangular membrane modules was investigated. Theoretical analysis of mass…”
    Get full text
    Journal Article
  8. 8

    Exponential model analysis of permeate flux for ultrafiltration in hollow-fiber modules by momentum balance by Yeh, H.M.

    “…The modified correlation equation for predicting the permeate flux of membrane ultrafiltration (UF) in hollow-fiber modules was derived from the complete…”
    Get full text
    Journal Article
  9. 9

    Heat-transfer enhancement in double-pass flat-plate solar air heaters with recycle by Ho, C.D., Yeh, H.M., Wang, R.C.

    Published in Energy (Oxford) (01-11-2005)
    “…This work theoretically and experimentally investigates a device for inserting an absorbing plate into the double-pass channel in a flat-plate solar air heater…”
    Get full text
    Journal Article
  10. 10

    Effect of External Recycle on Mass Transfer in Countercurrent Double-Pass Cross-Flow Rectangular Dialyzers by Yeh, H. M.

    Published in Separation science and technology (28-04-2011)
    “…A study on mass transfer in countercurrent cross-flow rectangular dialyzers with external recycle was investigated. Theoretical analysis of mass transfer in…”
    Get full text
    Journal Article
  11. 11

    Effects of reflux and reflux-barrier location on solvent extraction through cross-flow flat-plate membrane modules with internal reflux by Yeh, H.M.

    Published in Journal of membrane science (01-02-2006)
    “…The influence of reflux as well as reflux-barrier location on cross-flow membrane extraction through the flat-plate module with internal reflux has been…”
    Get full text
    Journal Article
  12. 12

    Effects of inclination angle and plate spacing on the enrichment of heavy water in continuous-type flat-plate thermal diffusion columns by Yeh, H.M.

    Published in Annals of nuclear energy (01-06-2009)
    “…The effects of inclination angle and plate spacing on the separation of heavy water from water isotope mixture in continuous-type flat-plate thermal diffusion…”
    Get full text
    Journal Article
  13. 13

    Momentum balance analysis of permeate flux for ultrafiltration in tubular membranes with gradually increasing incidental angles of a wired-rod insert by Yeh, H.M., Chen, Y.F.

    Published in Journal of membrane science (05-07-2006)
    “…It was reported in previous works that the performance of ultrafiltration in tubular membranes could be improved by concentrically inserting a steel rod, and…”
    Get full text
    Journal Article
  14. 14

    Ultrafiltration in a tubular membrane inserted concentrically with a solid rod of varying radius for improved performance by Yeh, H.M., Chen, Y.F.

    Published in Desalination (01-10-2009)
    “…Resistance-in-series analysis of the permeate flux for ultrafiltration in a tubular membrane inserted concentrically with a solid rod, having rod radius varied…”
    Get full text
    Journal Article
  15. 15
  16. 16

    Estimation of deuterium recovery from the separation of water isotopes in thermal-diffusion columns of a countercurrent-flow frazier scheme with optimal plate aspect ratio by Yeh, H.M.

    Published in Progress in nuclear energy (New series) (01-08-2009)
    “…The effect of plate aspect ratio on the performance of deuterium recovery from the separation of water–isotope mixture in thermal-diffusion columns of a…”
    Get full text
    Journal Article
  17. 17

    Design of flat-plate thermal diffusion columns for enrichment of heavy water with transverse sampling streams by Yeh, H.M.

    Published in Progress in nuclear energy (New series) (01-04-2009)
    “…Although there does not exist simultaneously the optimal angle of inclination and optimal plate spacing for maximum separation of heavy water from…”
    Get full text
    Journal Article
  18. 18

    Effects of design and operating parameters on the declination of permeate flux for membrane ultrafiltration along hollow-fiber modules by Yeh, H.M., Wu, H.P., Dong, J.F.

    Published in Journal of membrane science (01-03-2003)
    “…Correlation equations for predicting the permeate flux of membrane ultrafiltration in hollow-fiber modules were derived from momentum and mass balances with…”
    Get full text
    Journal Article
  19. 19

    Modified analysis of permeate flux for ultrafiltration in a solid-rod tubular membrane by Yeh, H.M., Chen, Y.F.

    Published in Journal of membrane science (01-04-2005)
    “…Resistance-in-series analysis of the permeate flux for ultrafiltration in a tubular membrane with a steel rod inserted concentrically was modified by momentum…”
    Get full text
    Journal Article
  20. 20

    Effect of rod-radius variation on ultrafiltration in a solid-rod tubular-membrane by Yeh, H.M., Huang, P.C.

    Published in Journal of membrane science (01-11-2004)
    “…The permeat flux in a tubular-membrane can be improved by inserted concentrically with a solid-rod of linearly varied rod-radius and fixed rod volume. The…”
    Get full text
    Journal Article