Search Results - "Xue, Ancheng"
-
1
Steady‐state PMU data selection for parameter identification of transmission line considering the influence of measurement error
Published in IET generation, transmission & distribution (01-11-2022)“…Phasor measurement units (PMUs) are important data source for parameter identification of the transmission line (TL). However, the “seesaw” phenomenon exists…”
Get full text
Journal Article -
2
A new four‐step method to identify the parameters of transmission line based on SCADA data
Published in IET generation, transmission & distribution (01-05-2022)“…Accurate parameters of transmission line (ParTL) are the basis of power system analysis. For high‐voltage transmission line (TL), remote terminal units (RTUs)…”
Get full text
Journal Article -
3
An Online Measurement Approach of Generators' Torsional Mechanical Damping Coefficients for Subsynchronous Oscillation Analysis
Published in IEEE transactions on power systems (01-03-2015)“…The series compensation capacitor and HVDC are widely used in Chinese power grids to increase the transmission capability of long distance lines, which might…”
Get full text
Journal Article -
4
Analysis of Sub-Synchronous Band Oscillation in a DFIG System With Non-Smooth Bifurcation
Published in IEEE access (2019)“…With the interconnection of large-scale wind power, the sub-synchronous oscillation (SSO) which is mainly analyzed by the local small-signal method occurs in…”
Get full text
Journal Article -
5
Data Dependence Analysis for Defects Data of Relay Protection Devices Based on Apriori Algorithm
Published in IEEE access (2020)“…Currently, a large amount of defect data in relay protection devices (RPDs) is accumulated in operation. However, the defect data dependence analysis is…”
Get full text
Journal Article -
6
Transient Frequency Stability Emergency Control for the Power System Interconnected With Offshore Wind Power Through VSC-HVDC
Published in IEEE access (2020)“…For the power system interconnected with the large-scale offshore wind power through VSC-HVDC, such as SZ power grid, it may be engaged with transient…”
Get full text
Journal Article -
7
Robust Identification Method for Transmission Line Parameters That Considers PMU Phase Angle Error
Published in IEEE access (2020)“…Accurate transmission line parameters are the basis of power system calculations. The measured phasor measurement unit (PMU) phase angle data at both ends of a…”
Get full text
Journal Article -
8
A New Quantitative Analysis Method for Overvoltage in Sending End Electric Power System with UHVDC
Published in IEEE access (01-01-2020)“…With the development of renewable electric power generation and ultra-high voltage direct current (UHVDC) transmission, the transient overvoltage in the…”
Get full text
Journal Article -
9
A quality evaluation method for the unstructured defect record of relay protection devices based on ontology and knowledge graph
Published in Energy reports (01-09-2023)“…The original unstructured record data for the defect of the relay protection devices (RPDs) may contain problems influencing the data mining, and it is lack of…”
Get full text
Journal Article -
10
Online Pattern Recognition and Data Correction of PMU Data Under GPS Spoofing Attack
Published in Journal of modern power systems and clean energy (01-11-2020)“…Smart grids are increasingly dependent on data with the rapid development of communication and measurement. As one of the important data sources of smart…”
Get full text
Journal Article -
11
Modeling and Analysis of Incorrect Actions of Relay Protection Systems Based on Fault Trees
Published in IEEE access (2020)“…The safety of the power grid is threatened by incorrect action (IA) of relay protection system (RPS) resulting from defects, and even worsen a blackout…”
Get full text
Journal Article -
12
On the mechanism and control for the ultra-low frequency oscillation in NY Power Grid with large-scale hydropower
Published in Control theory and technology (01-08-2019)“…The power grid with large proportion of hydropower may engage the ultra-low frequency oscillation (ULFO), which threatening the operation of system. To the NY…”
Get full text
Journal Article -
13
Correction of Time-varying PMU Phase Angle Deviation with Unknown Transmission Line Parameters
Published in CSEE Journal of Power and Energy Systems (2023)Get full text
Journal Article -
14
A New Non-Smooth Simplified Model for DFIG in Electromechanical Transient Analysis
Published in IEEE access (2020)“…The transient of the DFIG engages a lot of non-smooth elements such as switches of controllers and saturation of limiters, thus, the simplified non-smooth…”
Get full text
Journal Article -
15
A Novel Method for Screening the PMU Phase Angle Difference Data Based on Hyperplane Clustering
Published in IEEE access (2019)“…Compared with the traditional supervisory control and data acquisition (SCADA) data, phasor measurement unit (PMU) data is characterized by phase angle…”
Get full text
Journal Article -
16
A New Transient Frequency Acceptability Margin Based on the Frequency Trajectory
Published in Energies (Basel) (01-01-2019)“…When the electric power system is disturbed, the transient frequency deviation may be large and harmful to its stable operation, especially in some small power…”
Get full text
Journal Article -
17
A New Robust Identification Method for Transmission Line Parameters Based on ADALINE and IGG Method
Published in IEEE access (2020)“…Accurate transmission line parameters are the basis of power system calculations. Aiming at obtaining accuracy online transmission line parameters in the case…”
Get full text
Journal Article -
18
Characteristics of PMU Phase Angle Difference Induced by Frequency Deviation of Crystal Oscillator and its Detection Method
Published in IEEE access (2020)“…Phasor measurement unit (PMU), which could provide high-frequency phasors including the amplitude and phase angle synchronized with Global Positioning System…”
Get full text
Journal Article -
19
A PMU data recovering method based on preferred selection strategy
Published in Global Energy Interconnection (01-01-2018)“…Nowadays, the technology of renewable sources grid-connection and DC transmission has a rapid development. And phasor measurement units (PMUs) become more…”
Get full text
Journal Article -
20
On power system blackout modeling and analysis based on self-organized criticality
Published in Science China. Technological sciences (01-02-2008)“…This paper makes a comprehensive survey on power system blackout modeling and analysis based on SOC (self-organized criticality). Firstly, a generalized SOC…”
Get full text
Journal Article