Search Results - "Wyszyński, G."
-
1
Active compensation of magnetic field distortions based on vector spherical harmonics field description
Published in AIP advances (01-03-2017)“…An analytic solution to the magnetostatic inverse problem in the framework of vector spherical harmonic basis functions is presented. This formalism is used…”
Get full text
Journal Article -
2
Measurement of the Permanent Electric Dipole Moment of the Neutron
Published in Physical review letters (28-02-2020)“…We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of…”
Get full text
Journal Article -
3
Highly stable atomic vector magnetometer based on free spin precession
Published in Optics express (24-08-2015)“…We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 μT magnetic field. Multiple circularly polarized…”
Get full text
Journal Article -
4
Constraining interactions mediated by axion-like particles with ultracold neutrons
Published in Physics letters. B (18-05-2015)“…We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored…”
Get full text
Journal Article -
5
Observation of Gravitationally Induced Vertical Striation of Polarized Ultracold Neutrons by Spin-Echo Spectroscopy
Published in Physical review letters (16-10-2015)“…We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a |B0|=1 μT magnetic field. We have demonstrated…”
Get full text
Journal Article -
6
A measurement of the neutron to 199Hg magnetic moment ratio
Published in Physics letters. B (12-12-2014)“…The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold…”
Get full text
Journal Article -
7
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-07-2018)“…We report on a laser based 199Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a…”
Get full text
Journal Article -
8
A device for simultaneous spin analysis of ultracold neutrons
Published in The European physical journal. A, Hadrons and nuclei (01-11-2015)“… We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the…”
Get full text
Journal Article -
9
Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field
Published in The European physical journal. D, Atomic, molecular, and optical physics (01-10-2015)“…We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated…”
Get full text
Journal Article -
10
Constraining interactions mediated by axion-like particles with ultracold neutrons
Published 11-12-2014“…We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored…”
Get full text
Journal Article -
11
Measurement of a false electric dipole moment signal from 199Hg atoms exposed to an inhomogeneous magnetic field
Published in The European physical journal. D, Atomic, molecular, and optical physics (06-10-2015)“…We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for 199 Hg atoms contained in a volume permeated with…”
Get full text
Journal Article -
12
A measurement of the neutron to 199 Hg magnetic moment ratio
Published in Physics letters. B (01-12-2014)Get full text
Journal Article -
13
Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment
Published 03-05-2022“…Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron…”
Get full text
Journal Article -
14
Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment
Published 28-04-2020“…Phys. Rev. A 101, 053419 (2020) An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment…”
Get full text
Journal Article -
15
Magnetic field uniformity in neutron electric dipole moment experiments
Published 30-08-2019“…Phys. Rev. A 99, 042112 (2019) Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A…”
Get full text
Journal Article -
16
Measurement of the permanent electric dipole moment of the neutron
Published 31-01-2020“…Phys. Rev. Lett. 124, 081803 (2020) We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer…”
Get full text
Journal Article -
17
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
Published 16-04-2018“…NIM A 896 (2018) 129-138 We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of…”
Get full text
Journal Article -
18
A highly stable atomic vector magnetometer based on free spin precession
Published 30-07-2015“…Optics Express Vol. 23, Issue 17, pp. 22108-22115 (2015) We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction…”
Get full text
Journal Article -
19
Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy
Published 08-09-2015“…Phys. Rev. Lett. 115, 162502 (2015) We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a…”
Get full text
Journal Article -
20
A device for simultaneous spin analysis of ultracold neutrons
Published 24-02-2015“…We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the…”
Get full text
Journal Article