Search Results - "Wroblewski, B.M"
-
1
Triple taper polished cemented stem in total hip arthroplasty: Rationale for the design, surgical technique, and 7 years of clinical experience
Published in The Journal of arthroplasty (01-12-2001)“…Successful long-term clinical results with the Charnley low-friction torque arthroplasty have identified proximal femoral strain shielding as a long-term…”
Get full text
Journal Article -
2
Polyethylene particles of a ‘critical size’ are necessary for the induction of cytokines by macrophages in vitro
Published in Biomaterials (01-12-1998)“…Particulate wear debris from total hip prosthetic components can stimulate macrophages to produce mediators of osteolysis which may cause aseptic implant…”
Get full text
Journal Article -
3
PII: S1479-666X(04)80103-3
Published in The surgeon (Edinburgh) (2004)Get full text
Journal Article -
4
Charnley Low-Frictional Torque Arthroplasty for Avascular Necrosis of the Femoral Head
Published in The Journal of arthroplasty (01-10-2005)“…Forty-nine patients (mean age, 37 years; 20-50 years) had had 69 Charnley low-frictional arthroplasties for avascular necrosis of the femoral head. Their mean…”
Get full text
Journal Article -
5
The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets
Published in Medical engineering & physics (01-12-1997)“…The study was undertaken to investigate the association, if any, between the surface roughness of 35 explanted femoral heads and the clinical wear factors of…”
Get full text
Journal Article -
6
Comparative study of the activity of total hip arthroplasty patients and normal subjects
Published in The Journal of arthroplasty (01-08-2001)“…The walking activity of normal subjects and total hip arthroplasty (THA) patients from the Wrightington Hospital for Joint Disease and The General Infirmary at…”
Get full text
Journal Article -
7
Contamination of the visors of total body exhaust suits in total hip replacement surgery
Published in Hip international (01-07-2004)“…We examined 40 visors, used with the Charnley helmets and the total body exhaust suits, for contamination with blood, fat, or washout fluids during primary and…”
Get full text
Journal Article -
8
The effect of activity levels of total hip arthroplasty patients on socket penetration
Published in The Journal of arthroplasty (01-08-2001)“…Survivorship of total hip arthroplasties (THAs) has been linked to penetration of the femoral head into the polyethylene acetabular cup and to polyethylene…”
Get full text
Journal Article -
9
A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene
Published in The Journal of arthroplasty (01-12-2001)“…Cross-linked polyethylenes are being introduced widely in acetabular cups in hip prostheses as a strategy to reduce the incidence of wear debris–induced…”
Get full text
Journal Article -
10
Charnley low frictional torque arthroplasty: clinical developments
Published in The Orthopedic clinics of North America (01-01-2005)Get more information
Journal Article -
11
Contamination of the visors of total body exhaust suits in total hip replacement surgery
Published in Hip international (2004)Get full text
Journal Article -
12
Outcome of revision for mechanical stem failure using the cemented Charnley's stem
Published in The Journal of arthroplasty (01-06-1996)“…Three hundred ninety-nine cemented stem revision total hip arthroplasties performed in cases with mechanical stem failure without infection and having a…”
Get full text
Journal Article -
13
Determination of the trabecular bone direction from digitised radiographs
Published in Medical engineering & physics (01-11-2003)“…There is increasing evidence for monitoring the bone trabecular structure to explain, in part, the mechanical properties of bone. Despite the emergence of…”
Get full text
Journal Article -
14
Fatal pulmonary embolism and mortality after revision of failed total hip arthroplasties
Published in The Journal of arthroplasty (01-06-2000)“…To assess the effect of extensive surgery and delayed mobilization on postoperative incidence of fatal pulmonary embolism, we reviewed the mortality rate in…”
Get full text
Journal Article -
15
A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE
Published in Bio-medical materials and engineering (1997)“…Damage to polished femoral heads in vivo can cause increased wear of acetabular cups. Oxidation and ageing after sterilisation by gamma irradiation in air, can…”
Get more information
Journal Article -
16
Wear and fracture of the acetabular cup in Charnley low-friction arthroplasty
Published in The Journal of arthroplasty (01-02-1998)“…Seven cases of progressive wear-out and fracture of the cemented high-density polyethylene cup in Charnley low-friction arthroplasty were identified in a group…”
Get full text
Journal Article -
17
Femoral head autograft and contralateral total hip arthroplasty
Published in The Journal of arthroplasty (01-04-1993)“…Femoral head autograft from a primary total hip arthroplasty side was used to supplement deficient bone stock on the contralateral revision side. Five patients…”
Get more information
Journal Article -
18
(iii) The infected total hip replacement
Published in Current orthopaedics (01-07-2000)Get full text
Journal Article -
19
Discrepancy in the length of the tibiae in unilateral congenital dislocation of the hip
Published in The Journal of arthroplasty (01-10-1999)“…We measured discrepancy in the length of the tibiae in cases of unilateral congenital dislocation of the hip (CDH) in 10 patients. The mean shortening of the…”
Get full text
Journal Article -
20
Wear and loosening of the socket in the Charnley low-friction arthroplasty
Published in The Orthopedic clinics of North America (01-07-1988)“…In the Charnley low-friction arthroplasty, wear of the HDP socket and the dimensional changes resulting from it are more important than the tissue response to…”
Get more information
Journal Article