Search Results - "Wouters, P A A F"
-
1
Approximation of transmission line parameters of single-core and three-core XLPE cables
Published in IEEE transactions on dielectrics and electrical insulation (01-02-2010)“…A transmission line model of a power cable is required for the analysis of the behavior of high-frequency phenomena, such as partial discharges, lightning…”
Get full text
Journal Article -
2
Adaptive templates for matched filter bank for continuous online partial discharge monitoring
Published in IEEE transactions on dielectrics and electrical insulation (01-10-2011)“…Matched filtering can be applied to recorded signals for maximum detection sensitivity during online partial discharge (PD) measurements in medium-voltage…”
Get full text
Journal Article -
3
Temperature Dependency of Ion Mobility in Synthetic Ester by Dielectric Response Analysis in Time and Frequency Domain
Published in IEEE transactions on dielectrics and electrical insulation (01-08-2023)“…Synthetic ester is a promising alternative to mineral oil for emerging applications relying on high-power static conversion, such as solid-state transformers…”
Get full text
Journal Article -
4
Operational conditions influencing the partial discharge performance of cables under low and medium vacuum
Published in IEEE transactions on dielectrics and electrical insulation (01-02-2019)“…The performance of flexible cables for applications at the kilovolt level over a gas pressure range from below 1 Pa to ambient needs to be quantified. Braided…”
Get full text
Journal Article -
5
Fault development upon water ingress in damaged low voltage underground power cables with polymer insulation
Published in IEEE transactions on dielectrics and electrical insulation (01-04-2017)“…Developments in the electricity sector, related to integration of sustainable energy, not only affects the medium voltage but also the low voltage…”
Get full text
Journal Article -
6
Capacitive Current Interruption by HV Air-Break Disconnectors With High-Velocity Opening Auxiliary Contacts
Published in IEEE transactions on power delivery (01-10-2011)“…Air-break disconnectors (DS) in a high-voltage network can interrupt small capacitive currents (e.g., occurring when disconnecting short unloaded transmission…”
Get full text
Journal Article -
7
Capacitive Current Interruption With Air-Break High Voltage Disconnectors
Published in IEEE transactions on power delivery (01-04-2010)“…Capacitive current interruption with air-break disconnectors in a high-voltage network is an interactive event between the circuit and arc with a variety of…”
Get full text
Journal Article -
8
33kV cable connector failures due to shunt reactor switching by means of vacuum circuit breaker – A thorough investigation & mitigation analysis
Published in Electric power systems research (01-11-2023)“…•In this paper, the findings and conclusions of a complete failure investigation process and mitigation analysis are presented with respect to the switching of…”
Get full text
Journal Article -
9
Partial discharge detection for characterizing cable insulation under low and medium vacuum conditions
Published in IEEE transactions on dielectrics and electrical insulation (01-02-2018)“…Design of cables for operation in a low pressure environment is challenging, when applications also demand lightweight and flexibility, and material choice is…”
Get full text
Journal Article -
10
High frequency modeling of a shielded four-core low voltage underground power cable
Published in IEEE transactions on dielectrics and electrical insulation (01-04-2015)“…Underground low voltage (LV) power cables have a long life span, and so far minimum effort was put in methods for condition assessment. However, a slow but…”
Get full text
Journal Article -
11
Investigation of necessary modeling detail of a large scale EHV transmission network for slow front transients
Published in Electric power systems research (01-06-2017)“…•EHV transmission network modeling for slow front transients according to guidelines.•Effect of pylon height and transposition when modeling Overhead…”
Get full text
Journal Article -
12
Accurate estimation of the time-of-arrival of partial discharge pulses in cable systems in service
Published in IEEE transactions on dielectrics and electrical insulation (01-08-2008)“…Accurate location of the origins of partial discharges in power cable systems, based on arrival times, is imperative for the identification and assessment of…”
Get full text
Journal Article -
13
Influence of Ring Main Units and Substations on Online Partial-Discharge Detection and Location in Medium-Voltage Cable Networks
Published in IEEE transactions on power delivery (01-04-2011)“…Online partial-discharge (PD) monitoring of medium-voltage power cables is traditionally performed on a cable between two consecutive ring main units (RMUs)…”
Get full text
Journal Article -
14
Partial discharge parameters to evaluate the insulation condition of on-line located defects in medium voltage cable networks
Published in IEEE transactions on dielectrics and electrical insulation (01-06-2011)“…Partial discharge analysis has a long record as reliable diagnostic tool to assess the integrity and the quality of electrical insulation of power systems…”
Get full text
Journal Article -
15
Arc Imaging on Capacitive Current Interruption Using a Disconnector with an Auxiliary Interrupter
Published in 2011 Asia-Pacific Power and Energy Engineering Conference (01-03-2011)“…A series of experiments on the capacitive current interruption using an air-break disconnector (DS) with an Auxiliary Interrupter (AI) is presented. The AI…”
Get full text
Conference Proceeding -
16
Modeling of Replacement Alternatives for Power Transformer Populations
Published in IEEE transactions on power delivery (01-04-2012)“…The age of the majority of power transformers installed in the western electricity network reaches 30 to 60 years and replacement on short term seems eminent…”
Get full text
Journal Article -
17
Influence of solar irradiation on power transformer thermal balance
Published in IEEE transactions on dielectrics and electrical insulation (01-12-2012)“…In countries with a high ambient temperature and strong solar irradiation, transformer winding hot-spot temperature may increase over its maximum permissible…”
Get full text
Journal Article -
18
Challenges in Wave-Velocity Based Cable Temperature Monitoring for Widespread Implementation in Medium-Voltage Networks
Published in 2024 IEEE International Conference on High Voltage Engineering and Applications (ICHVE) (18-08-2024)“…Knowledge on the temperature of the mediumvoltage network is essential for optimising its utilisation. This is even more imperative now many networks are…”
Get full text
Conference Proceeding -
19
Measurement of Transient Overvoltages from Fast Switching of an Inductive Load using Open-Air Capacitive Sensors
Published in 2024 IEEE International Conference on High Voltage Engineering and Applications (ICHVE) (18-08-2024)“…Energization and de-energization of electric power components cause transient overvoltages that potentially can damage installations. Particularly, fast…”
Get full text
Conference Proceeding -
20
Detection limitation of high frequency signal travelling along underground power cable
Published in 2013 IEEE International Conference on Solid Dielectrics (ICSD) (01-06-2013)“…High frequency pulse injection is part of many diagnostics techniques, e.g. cable fault location. An injected pulse along an underground power cable will…”
Get full text
Conference Proceeding