Search Results - "Windisch, Christoph"
-
1
Changes of posterior condylar offset results in midflexion instability in single-radius total knee arthroplasty
Published in Archives of orthopaedic and trauma surgery (01-05-2017)“…Introduction There is no algorithm for the management of joint stability in midflexion up to now. Change in the joint line (JL) is considered to be the primary…”
Get full text
Journal Article -
2
Sex Differences in Serum C-Reactive Protein Course after Total Hip Arthroplasty
Published in Clinics in orthopedic surgery (01-03-2022)“…Gender-specific medicine has become an important part in investigating the course of various diseases. C-reactive protein (CRP) is used as an inflammatory…”
Get full text
Journal Article -
3
Patient Obesity Influences Pelvic Lift During Cup Insertion in Total Hip Arthroplasty Through a Lateral Transgluteal Approach in Supine Position
Published in The Journal of arthroplasty (01-09-2017)“…Abstract Background Movement of the pelvis during implantation of total hip arthroplasty (THA) has a major influence on the positioning of the acetabular cup…”
Get full text
Journal Article -
4
Course of pelvic lift during total hip arthroplasty
Published in Archives of orthopaedic and trauma surgery (2017)“…Introduction The position of the cup makes a major contribution to the success of total hip arthroplasty (THA). In conventional implantation of the prosthesis…”
Get full text
Journal Article -
5
Unsatisfactory Outcome of Arthrodesis Performed After Septic Failure of Revision Total Knee Arthroplasty
Published in Journal of bone and joint surgery. American volume (18-02-2015)“…BACKGROUND:Periprosthetic infection is one of the most dreaded orthopaedic complications. Current treatment procedures include one-stage or two-stage revision…”
Get full text
Journal Article -
6
Effects of Kinesio taping compared to arterio-venous Impulse System™ on limb swelling and skin temperature after total knee arthroplasty
Published in International orthopaedics (01-02-2017)“…Purpose It is an established fact that post-operative (p.o.) soft-tissue swelling and lymphoedema after total knee arthroplasty (TKA) have a major influence on…”
Get full text
Journal Article -
7
The C-reactive protein level after total knee arthroplasty is gender specific
Published in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA (01-10-2016)“…Purpose Laboratory diagnostics are part of the routine before and after operations. In all specialist surgical disciplines, including orthopaedic surgery, the…”
Get full text
Journal Article -
8
C-reactive protein course during the first 5 days after total knee arthroplasty cannot predict early prosthetic joint infection
Published in Archives of orthopaedic and trauma surgery (01-08-2017)“…Introduction Periprosthetic joint infection (PJI) is one of the most devastating major complications after total knee arthroplasty (TKA). The laboratory value…”
Get full text
Journal Article -
9
The reversed gap technique produces anatomical alignment with less midflexion instability in total knee arthroplasty: a prospective randomized trial
Published in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA (01-08-2016)“…Purpose No surgical technique is capable of controlling the stability of the joint in midflexion. The purpose of the present study was to present and evaluate…”
Get full text
Journal Article -
10
Morbidly Obese Patients Undergoing Reduced Cup Anteversion Through a Direct Lateral Approach
Published in Journal of bone and joint surgery. American volume (04-05-2016)“…The presence of obesity negatively affects the results after total hip arthroplasty. The influence of morbid obesity on cup positioning is investigated. A…”
Get full text
Journal Article -
11
The volume of the human knee joint
Published in Archives of orthopaedic and trauma surgery (01-10-2015)“…Introduction Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date…”
Get full text
Journal Article -
12
-
13
Regional differences in temperature course after knee arthroplasty
Published in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA (01-08-2016)“…Purpose During wound healing after surgery, physiological inflammation leads to an increase in soft tissue perfusion. This is reflected by a characteristic…”
Get full text
Journal Article -
14
Erratum to: Regional differences in temperature course after knee arthroplasty
Published in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA (01-11-2017)Get full text
Journal Article -
15
Opening-Wedge High Tibial Osteotomy with a Locked Low-Profile Plate
Published in Journal of bone and joint surgery. American volume (01-11-2009)“…BackgroundHigh tibial osteotomy has been recognized as a beneficial treatment for osteoarthritis of the medial compartment of the knee. The purpose of this…”
Get full text
Journal Article -
16
-
17
Influence of Surgical Approach on Pelvic Lift in Hip Arthroplasty During Cup Insertion
Published in Orthopedics (Thorofare, N.J.) (01-07-2017)“…The position of the acetabular cup is a major factor in the long-term outcome of total hip arthroplasty (THA). Malpositioning of the acetabular cup frequently…”
Get full text
Journal Article -
18
Human osteoblast damage after antiseptic treatment
Published in International orthopaedics (01-01-2014)“…Purpose Antiseptics are powerful medical agents used for wound treatment and decontamination and have a high potential for defeating joint infections in septic…”
Get full text
Journal Article -
19
Psychological distress and health-related quality of life in patients with bone marrow edema syndrome
Published in Annals of translational medicine (01-10-2019)“…The aim of the study was to investigate psychological distress and health-related quality of life (HrQoL) in patients with bone marrow edema syndrome (BMES) of…”
Get full text
Journal Article -
20
High failure rate of a new pressfit cup in mid-term follow-up
Published in International orthopaedics (01-09-2015)“…Background Unacceptably high rates of loosening of a novel cementless cup system (Mathys, SeleXys TH+) have been reported. In this study, our mid-term-results…”
Get full text
Journal Article