Search Results - "Willborn, K"
-
1
Erratum: “Performance Parameters of a Liquid Filled Ionization Chamber Array” [Med. Phys. 40, 082106 (2013)]
Published in Medical physics (Lancaster) (01-10-2019)Get full text
Journal Article -
2
Performance parameters of a liquid filled ionization chamber array
Published in Medical physics (Lancaster) (01-08-2013)“…Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in…”
Get full text
Journal Article -
3
DAVID--a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques
Published in Physics in medicine & biology (07-03-2006)“…Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the…”
Get more information
Journal Article -
4
3056 Influence of maintenance therapy on incidence of 2nd line therapy and OS in NSCLC IV
Published in European journal of cancer (1990) (01-09-2015)Get full text
Journal Article -
5
3119 P53 disruptive mutation is a negative predictive factor in EGFR M+ NSCLC treated with TKI
Published in European journal of cancer (1990) (01-09-2015)Get full text
Journal Article -
6
SU‐E‐T‐62: Dosimetric Properties of the Octavius 1000SRS Liquid Filled Ionization Chamber Array
Published in Medical Physics (01-06-2013)“…Purpose: The two‐dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW‐Freiburg, Germany), being the conceptual successor of the LA48 linear…”
Get full text
Conference Proceeding Journal Article -
7
SU‐E‐T‐60: Evaluation of a Two‐Dimensional Ionization Chamber Array for Proton Beam Dosimetry
Published in Medical Physics (01-06-2013)“…Purpose: The application of the two‐dimensional ionization chamber array Octavius 729xdr (PTW‐Freiburg, Germany) in proton beam dosimetry, consisting of 729…”
Get full text
Conference Proceeding Journal Article -
8
SU‐E‐T‐332: Verification of Prostate VMAT Treatment Plans Using the Octavius 4D System
Published in Medical Physics (01-06-2013)“…Purpose: The introduction of rotational therapy1 has made a refinement of commonly used plan verification processes necessary. In this work the applicability…”
Get full text
Conference Proceeding Journal Article -
9
SU‐E‐T‐343: Monte Carlo Study on a Novel Direction‐Selective Flattening Filter System
Published in Medical Physics (01-06-2011)“…Purpose: Monte Carlo evaluation of a newly‐designed narrow steel cone flattening filter, which functions via the direction‐selective attenuation of the photons…”
Get full text
Conference Proceeding Journal Article -
10
Enhanced accuracy of the permanent surveillance of IMRT deliveries by iterative deconvolution of DAVID chamber signal profiles
Published in Physics in medicine & biology (21-07-2010)“…In vivo dosimetry systems, capable of permanently monitoring IMRT treatment deliveries throughout all fractions, are increasingly used in clinical practice…”
Get more information
Journal Article -
11
-
12
SU‐E‐T‐65: On the Dose Response Function and the Energy Dependence of a Novel Synthetic Single Crystal Diamond Detector
Published in Medical Physics (01-06-2013)“…Purpose: To characterize the dose response function K(x) and to analyze the dependence on changing photon spectra of a novel synthetic single crystal diamond…”
Get full text
Conference Proceeding Journal Article -
13
SU‐E‐T‐439: Implementation of an Iterative Deconvolution Method in a Daily In‐Vivo Verification Procedure with the DAVID System
Published in Medical Physics (01-06-2011)“…Purpose: The DAVID system (PTW‐Freiburg, Germany) is a multiwire ionization chamber placed in the accessory holder, capable of continuously monitoring…”
Get full text
Conference Proceeding Journal Article -
14
SU‐E‐T‐131: Iterative Deconvolution of Dose Profile Measurements with Ionization Chambers Based on Lorentz‐Type Lateral Response Functions of the Detectors
Published in Medical Physics (01-06-2011)“…Purpose: In this work it is shown that the volume effect of ionization chamber can be corrected by the application of a van‐Cittert iterative deconvolution…”
Get full text
Conference Proceeding Journal Article -
15
SU‐E‐T‐139: Note on the Underestimation of the Dosimetrical Significance of Detected IMRT Verification Deviations Using the Gamma‐Index Method and a Global Acceptance Criterion Based on the Number of Passing Points
Published in Medical Physics (01-06-2011)“…Purpose: Possible underestimations of the dosimetrical impact of Gamma‐Index detected dose deviations due to the choice of the maximum dose in the analysis…”
Get full text
Conference Proceeding Journal Article -
16
SU‐GG‐T‐182: Two Years of Clinical Experience with DAVID ‐ A Translucent Multi‐Wire Detector for On‐Line Verification of Patient Treatments
Published in Medical Physics (01-06-2010)“…Purpose: The DAVID system is used as an independent monitor system positioned between MLC and patient to assure the correct application of IMRT deliveries. In…”
Get full text
Conference Proceeding Journal Article -
17
SU‐GG‐T‐183: Enhanced Accuracy of IMRT Photon Fluence Profile Surveillance: Iterative Resolution Correction of the DAVID Chamber
Published in Medical Physics (01-06-2010)“…Purpose: The DAVID system (PTW‐Freiburg, Germany) is a multiwire ionization chamber placed in the accessory holder, capable of continuously monitoring…”
Get full text
Conference Proceeding Journal Article -
18
SU‐FF‐T‐252: Clinical Application of the DAVID System and 2D‐ARRAY for Quality Assurance in IMRT Treatments
Published in Medical Physics (01-06-2009)“…Purpose: A complete IMRT QA program based on a combination of the 2D‐ARRAY and the DAVID system (both PTW‐Freiburg, Germany) is implemented in our clinic to…”
Get full text
Conference Proceeding Journal Article -
19
SU‐FF‐T‐231: Adaptive Warning and Alarm Levels for Error Detection with the DAVID System
Published in Medical Physics (01-06-2009)“…Purpose: A method to determine adaptive warning and alarm levels is developed in order to enhance the error detection capability of the DAVID system. Method…”
Get full text
Conference Proceeding Journal Article -
20
SU‐FF‐T‐191: Considerations of Reference Level Definition for IMRT Plan Verification and Application of a Three Dimensional Gamma‐Index Analysis
Published in Medical Physics (01-06-2009)“…Purpose: A 3D Gamma Index analysis and different local reference levels for the dose axis are evaluated. Method and Materials: The Gamma‐Index method is…”
Get full text
Conference Proceeding Journal Article