Search Results - "Wilderman, Scott J."

Refine Results
  1. 1

    DblurDoseNet: A deep residual learning network for voxel radionuclide dosimetry compensating for single‐photon emission computerized tomography imaging resolution by Li, Zongyu, Fessler, Jeffrey A., Mikell, Justin K., Wilderman, Scott J., Dewaraja, Yuni K.

    Published in Medical physics (Lancaster) (01-02-2022)
    “…Purpose Current methods for patient‐specific voxel‐level dosimetry in radionuclide therapy suffer from a trade‐off between accuracy and computational…”
    Get full text
    Journal Article
  2. 2

    Experimental validation of Monte Carlo dosimetry for therapeutic beta emitters with radiochromic film in a 3D‐printed phantom by Van, Benjamin, Dewaraja, Yuni K., Niedbala, Jeremy T., Rosebush, Gerrid, Kazmierski, Matthew, Hubers, David, Mikell, Justin K., Wilderman, Scott J.

    Published in Medical physics (Lancaster) (01-01-2023)
    “…Purpose Validation of dosimetry software, such as Monte Carlo (MC) radiation transport codes used for patient‐specific absorbed dose estimation, is critical…”
    Get full text
    Journal Article
  3. 3
  4. 4

    A Pipeline for Automated Voxel Dosimetry: Application in Patients with Multi-SPECT/CT Imaging After 177Lu-Peptide Receptor Radionuclide Therapy by Dewaraja, Yuni K, Mirando, David M, Peterson, Avery B, Niedbala, Jeremy, Millet, John D, Mikell, Justin K, Frey, Kirk A, Wong, Ka Kit, Wilderman, Scott J, Nelson, Aaron S

    Published in The Journal of nuclear medicine (1978) (01-11-2022)
    “…Patient-specific dosimetry in radiopharmaceutical therapy (RPT) is impeded by the lack of tools that are accurate and practical for the clinic. Our aims were…”
    Get full text
    Journal Article
  5. 5

    Use of integrated SPECT/CT imaging for tumor dosimetry in I-131 radioimmunotherapy: a pilot patient study by Dewaraja, Yuni K, Wilderman, Scott J, Koral, Kenneth F, Kaminski, Mark S, Avram, Anca M

    Published in Cancer biotherapy & radiopharmaceuticals (01-08-2009)
    “…Integrated systems combining functional (single-photon emission computed tomography; SPECT) imaging with anatomic (computed tomography; CT) imaging have the…”
    Get more information
    Journal Article
  6. 6

    Y-90 SPECT ML image reconstruction with a new model for tissue-dependent bremsstrahlung production using CT information: a proof-of-concept study by Lim, Hongki, Fessler, Jeffrey A, Wilderman, Scott J, Brooks, Allen F, Dewaraja, Yuni K

    Published in Physics in medicine & biology (22-05-2018)
    “…While the yield of positrons used in Y-90 PET is independent of tissue media, Y-90 SPECT imaging is complicated by the tissue dependence of bremsstrahlung…”
    Get more information
    Journal Article
  7. 7
  8. 8

    Comparison of I-131 radioimmunotherapy tumor dosimetry: unit density sphere model versus patient-specific Monte Carlo calculations by Howard, David M, Kearfott, Kimberlee J, Wilderman, Scott J, Dewaraja, Yuni K

    Published in Cancer biotherapy & radiopharmaceuticals (01-10-2011)
    “…High computational requirements restrict the use of Monte Carlo algorithms for dose estimation in a clinical setting, despite the fact that they are considered…”
    Get more information
    Journal Article
  9. 9

    Methodology to incorporate biologically effective dose and equivalent uniform dose in patient-specific 3-dimensional dosimetry for non-Hodgkin lymphoma patients targeted with 131I-tositumomab therapy by Amro, Hanan, Wilderman, Scott J, Dewaraja, Yuni K, Roberson, Peter L

    Published in The Journal of nuclear medicine (1978) (01-04-2010)
    “…A 3-dimensional (3D) imaging-based patient-specific dosimetry methodology incorporating antitumor biologic effects using biologically effective dose (BED) and…”
    Get full text
    Journal Article
  10. 10

    Biological-effect modeling of radioimmunotherapy for non-hodgkins lymphoma: determination of model parameters by Roberson, Peter L, Wilderman, Scott J, Avram, Anca M, Kaminski, Mark S, Schipper, Matthew J, Dewaraja, Yuni K

    Published in Cancer biotherapy & radiopharmaceuticals (01-02-2014)
    “…Treatment with Tositumomab and 131I tositumomab anti-CD20 radioimmunotherapy (Bexxar) yields a nonradioactive antibody antitumor response (the so-called cold…”
    Get more information
    Journal Article
  11. 11

    Bio-effect model applied to 131I radioimmunotherapy of refractory non-Hodgkin’s lymphoma by Roberson, Peter L., Amro, Hanan, Wilderman, Scott J., Avram, Anca M., Kaminski, Mark S., Schipper, Matthew J., Dewaraja, Yuni K.

    “…Purpose Improved data collection methods have improved absorbed dose estimation by tracking activity distributions and tumor extent at multiple time points,…”
    Get full text
    Journal Article
  12. 12

    131I-tositumomab radioimmunotherapy: initial tumor dose-response results using 3-dimensional dosimetry including radiobiologic modeling by Dewaraja, Yuni K, Schipper, Matthew J, Roberson, Peter L, Wilderman, Scott J, Amro, Hanan, Regan, Denise D, Koral, Kenneth F, Kaminski, Mark S, Avram, Anca M

    Published in The Journal of nuclear medicine (1978) (01-07-2010)
    “…For optimal treatment planning in radionuclide therapy, robust tumor dose-response correlations must be established. Here, fully 3-dimensional (3D) dosimetry…”
    Get full text
    Journal Article
  13. 13

    Accurate Dosimetry in 131I Radionuclide Therapy Using Patient-Specific, 3-Dimensional Methods for SPECT Reconstruction and Absorbed Dose Calculation by Dewaraja, Yuni K, Wilderman, Scott J, Ljungberg, Michael, Koral, Kenneth F, Zasadny, Kenneth, Kaminiski, Mark S

    Published in The Journal of nuclear medicine (1978) (01-05-2005)
    “…(131)I radionuclide therapy studies have not shown a strong relationship between tumor absorbed dose and response, possibly due to inaccuracies in activity…”
    Get full text
    Journal Article
  14. 14

    A Deep Residual Learning Network for Practical Voxel Dosimetry in Radionuclide Therapy by Li, Zongyu, Fessler, Jeffrey A., Mikell, Justin K., Wilderman, Scott J., Dewaraja, Yuni K.

    “…Current standard methods for voxel-level dosimetry in radionuclide therapy suffers from a tradeoff between accuracy and computational efficiency. Monte Carlo…”
    Get full text
    Conference Proceeding
  15. 15

    Experimental validation of the DPM Monte Carlo code using minimally scattered electron beams in heterogeneous media by Chetty, Indrin J, Moran, Jean M, Nurushev, Teamor S, McShan, Daniel L, Fraass, Benedick A, Wilderman, Scott J, Bielajew, Alex F

    Published in Physics in medicine & biology (07-06-2002)
    “…A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for…”
    Get more information
    Journal Article
  16. 16

    Benchmarking of the Dose Planning Method (DPM) Monte Carlo code using electron beams from a racetrack microtron by Chetty, Indrin J., Moran, Jean M., McShan, Daniel L., Fraass, Benedick A., Wilderman, Scott J., Bielajew, Alex F.

    Published in Medical physics (Lancaster) (01-06-2002)
    “…A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for dose…”
    Get full text
    Journal Article
  17. 17
  18. 18

    A Pipeline for Automated Voxel Dosimetry: Application in Patients with Multi-SPECT/CT Imaging After 177 Lu-Peptide Receptor Radionuclide Therapy by Dewaraja, Yuni K, Mirando, David M, Peterson, Avery B, Niedbala, Jeremy, Millet, John D, Mikell, Justin K, Frey, Kirk A, Wong, Ka Kit, Wilderman, Scott J, Nelson, Aaron S

    Published in The Journal of nuclear medicine (1978) (01-11-2022)
    “…Patient-specific dosimetry in radiopharmaceutical therapy (RPT) is impeded by the lack of tools that are accurate and practical for the clinic. Our aims were…”
    Get full text
    Journal Article
  19. 19

    Determining detector requirements for medical imaging applications by Clinthorne, Neal H., Ng, Chor-yi, Strobel, Joerg, Hua, Chia-ho, LeBlanc, James W., Wilderman, Scott J., Rogers, W.Leslie

    “…The Cramér–Rao lower bound on estimator variance is used as a tool for assessing radiation detector requirements for nuclear medicine imaging. The classical…”
    Get full text
    Journal Article
  20. 20

    Quantum noise in digital X-ray image detectors with optically coupled scintillators by Flynn, M.J., Hames, S.M., Wilderman, S.J., Ciarelli, J.J.

    Published in IEEE transactions on nuclear science (01-08-1996)
    “…Digital X-ray imaging detectors designed for soft X-rays (1 to 50 keV) are significant for medical mammography, dental radiography, microradiography, and…”
    Get full text
    Journal Article