Search Results - "Wielunski, M."
-
1
Intercomparison of radiation protection instrumentation in a pulsed neutron field
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-02-2014)“…In the framework of the EURADOS working group 11, an intercomparison of active neutron survey meters was performed in a pulsed neutron field (PNF). The aim of…”
Get full text
Journal Article -
2
Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems
Published in Medical physics (Lancaster) (01-05-2015)“…Purpose: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. Methods:…”
Get full text
Journal Article -
3
Electronic neutron dosimeter in high-energy neutron fields
Published in Radiation measurements (01-07-2018)“…In neutron fields including neutron energies above 20 MeV a conventional neutron dosimeter is not suitable for measurements of neutron personal dose…”
Get full text
Journal Article -
4
Thoron detection with an active Radon exposure meter--first results
Published in Review of scientific instruments (01-02-2014)“…For state-of-the-art discrimination of Radon and Thoron several measurement techniques can be used, such as active sampling, electrostatic collection, delayed…”
Get more information
Journal Article -
5
Simulation and calibration of an active neutron dosemeter
Published in Radiation protection dosimetry (01-10-2014)“…Here the latest development stages of the HMGU active neutron dosemeter are presented. This work includes the comparison of the dosemeter's response function,…”
Get full text
Journal Article -
6
Development of a new thoron progeny detector based on SSNTD and the collection by an electric field
Published in Radiation protection dosimetry (01-05-2011)“…The importance of (220)Rn (thoron) progeny for human exposure has been widely recognised in the past decades. Since no stable equilibrium factor was found…”
Get full text
Journal Article -
7
Intercomparison of radiation protection devices in a high-energy stray neutron field. Part III: Instrument response
Published in Radiation measurements (01-08-2009)“…The European Commission has funded within its 6th Framework Programme a three-year project (2005–2007) called CONRAD, COordinated Network for RAdiation…”
Get full text
Journal Article -
8
Intercomparison exercise with MeV neutrons using various electronic personal dosimeters
Published in Radiation measurements (01-02-2008)“…Electronic personal neutron dosimeters developed at GSF, PTB, and LMU, were exposed with mono-energetic neutrons at the PTB neutron irradiation facility in…”
Get full text
Journal Article Conference Proceeding -
9
Study of the sensitivity of neutron sensors consisting of a converter plus Si charged-particle detector
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-01-2004)“…With the aim of improving neutron sensors for monitoring external neutron exposure, we have analysed the workings of a converter plus silicon PIN diode…”
Get full text
Journal Article -
10
Comparison of passive dosimeters for secondary radiation measurements in scanning proton radiotherapy
Published in Physica medica (2014)Get full text
Journal Article -
11
Monte Carlo simulation of the CERN-EU High Energy Reference Field (CERF) facility
Published in Radiation measurements (01-04-2020)“…In the present paper Geant4 Monte Carlo simulations of the CERN-EU high-energy Reference Field (CERF) facility in Geneva, Switzerland, are presented. At this…”
Get full text
Journal Article -
12
A three si detector system for personnel neutron dosimetry developed by means of Monte Carlo simulation calculations
Published in Radiation protection dosimetry (2003)“…The aim of this study was the development of an electronic detection system for personnel neutron dosimetry. Converter type silicon detectors were used for…”
Get full text
Journal Article -
13
A comprehensive spectrometry study of a stray neutron radiation field in scanning proton therapy
Published in Physics in medicine & biology (07-06-2016)“…The purpose of this study is to characterize the stray neutron radiation field in scanning proton therapy considering a pediatric anthropomorphic phantom and a…”
Get more information
Journal Article -
14
A comprehensive Monte Carlo study of out-of-field secondary neutron spectra in a scanned-beam proton therapy gantry room
Published in Zeitschrift für medizinische Physik (01-05-2021)“…To simulate secondary neutron radiation fields that had been measured at different relative positions during phantom irradiation inside a scanning proton…”
Get full text
Journal Article -
15
-
16
Energy deposition distributions caused by fast neutrons in converter type silicon detectors
Published in Radiation effects and defects in solids (01-01-2002)“…Polyethylene converter silicon detectors have been developed as part of a dosimetry system for the application in neutron fields. Signals have been…”
Get full text
Journal Article -
17
SU-F-T-217: A Comprehensive Monte-Carlo Study of Out-Of-Field Secondary Neutron Spectra in a Scanned-Beam Proton Therapy Treatment Room
Published in Medical physics (Lancaster) (01-06-2016)“…Purpose: To simulate secondary neutron radiation-fields produced at different positions during phantom irradiation inside a scanning proton therapy gantry…”
Get full text
Journal Article -
18
Calculation of Pulse Height Distributions for Neutron Irradiated 6LiF Converter Silicon Detectors
Published in Radiation protection dosimetry (01-08-1999)“…6LiF converter silicon detectors have been developed as part of a dosimetry system for application in neutron fields. Signals have been investigated which are…”
Get full text
Journal Article Conference Proceeding -
19
Comparative investigation on copper oxides by depth profiling using XPS, RBS and GDOES
Published in Analytical and bioanalytical chemistry (01-10-1995)“…Depth profiling has been performed by using X-ray photoelectron spectrometry (XPS) in combination with Ar-ion sputtering, Rutherford backscattering…”
Get full text
Journal Article -
20
WE‐D‐17A‐05: Measurement of Stray Radiation Within An Active Scanning Proton Therapy Facility: EURADOS WG9 Intercomparison Exercise of Active Dosimetry Systems
Published in Medical physics (Lancaster) (01-06-2014)“…Purpose: Intercomparison of active dosemeters in the measurement of stray radiation at the Trento active‐scanning proton therapy facility. Methods: EURADOS WG9…”
Get full text
Journal Article