Search Results - "Whitten, W. B"

Refine Results
  1. 1

    Microfabricated quadrupole ion trap for mass spectrometer applications by Pau, S, Pai, C S, Low, Y L, Moxom, J, Reilly, P T A, Whitten, W B, Ramsey, J M

    Published in Physical review letters (31-03-2006)
    “…An array of miniaturized cylindrical quadrupole ion traps, with a radius of 20 microm, is fabricated using silicon micromachining using phosphorus doped…”
    Get full text
    Journal Article
  2. 2

    Planar Geometry for Trapping and Separating Ions and Charged Particles by Pau, S, Whitten, W. B, Ramsey, J. M

    Published in Analytical chemistry (Washington) (01-09-2007)
    “…A planar quadrupole ion trap is proposed. We have demonstrated an extremely large operating range by trapping ions and particles with mass-to-charge ratio…”
    Get full text
    Journal Article
  3. 3

    Pulsed-Ionization Miniature Ion Mobility Spectrometer by Xu, Jun, Whitten, W. B, Ramsey, J. M

    Published in Analytical chemistry (Washington) (15-08-2003)
    “…We have demonstrated a miniature ion mobility spectrometer (IMS) that employs single pulses of corona discharge ionization. IMS spectra of both positive and…”
    Get full text
    Journal Article
  4. 4

    Confinement and Manipulation of Individual Molecules in Attoliter Volumes by Kung, C.-Y, Barnes, M. D, Lermer, N, Whitten, W. B, Ramsey, J. M

    Published in Analytical chemistry (Washington) (01-02-1998)
    “…We report observation of fluorescence from individual rhodamine 6G molecules in streams of charged 1-μm-diameter water droplets. With this approach,…”
    Get full text
    Journal Article
  5. 5

    Space Charge Effects on Resolution in a Miniature Ion Mobility Spectrometer by Xu, Jun, Whitten, William B, Ramsey, J. Michael

    Published in Analytical chemistry (Washington) (01-12-2000)
    “…Miniaturization of ion mobility spectrometry (IMS) is expected to have many advantages, as well as difficulties, in the separation of chemical species at…”
    Get full text
    Journal Article
  6. 6

    Direct observation of the evolution of the soot carbonization process in an acetylene diffusion flame via real-time aerosol mass spectrometry by Reilly, P.T.A, Gieray, R.A, Whitten, W.B, Ramsey, J.M

    Published in Combustion and flame (01-07-2000)
    “…Real-time aerosol mass spectrometry was used to measure the size and composition of individual soot particles in an acetylene diffusion flame. This on-line…”
    Get full text
    Journal Article
  7. 7

    The Elucidation of Charge-Transfer-Induced Matrix Effects in Environmental Aerosols Via Real-Time Aerosol Mass Spectral Analysis of Individual Airborne Particles by Reilly, P. T. A., Lazar, A. C., Gieray, R. A., Whitten, W. B., Ramsey, J. M.

    Published in Aerosol science and technology (01-07-2000)
    “…Matrix effects in real-time aerosol mass spectrometry (RTAMS) were investigated using Standard Reference Materials (SRMs) obtained from the National Institute…”
    Get full text
    Journal Article
  8. 8

    High-Efficiency Molecular Counting in Solution:  Single-Molecule Detection in Electrodynamically Focused Microdroplet Streams by Lermer, N, Barnes, M. D, Kung, C.-Y, Whitten, W. B, Ramsey, J. M

    Published in Analytical chemistry (Washington) (01-06-1997)
    “…We report fluorescence detection of individual rhodamine 6G molecules using a linear quadrupole to focus streams of microdroplets through the waist of a…”
    Get full text
    Journal Article
  9. 9

    Tandem Mass Spectrometry of Individual Airborne Microparticles by Reilly, P. T. A., Gieray, R. A., Yang, M., Whitten, W. B., Ramsey, J. M.

    Published in Analytical chemistry (Washington) (01-01-1997)
    “…An apparatus for real-time MS/MS analysis of individual airborne microparticles by laser ablation in an ion trap is described. The performance has been…”
    Get full text
    Journal Article
  10. 10

    Real-time detection of individual airborne bacteria by Gieray, R.A., Reilly, P.T.A., Yang, M., Whitten, W.B., Ramsey, J.M.

    Published in Journal of microbiological methods (01-06-1997)
    “…Airborne bacteria and bacterial spores were directly sampled by an ion trap mass spectrometer with an atmospheric pressure inlet system. Samples were…”
    Get full text
    Journal Article
  11. 11

    Fullerene Evolution in Flame-Generated Soot by Reilly, P. T. A, Gieray, R. A, Whitten, W. B, Ramsey, J. M

    Published in Journal of the American Chemical Society (29-11-2000)
    “…Direct observation of the chemical evolution of flame-generated soot was demonstrated for the first time using real-time aerosol mass spectrometry. The data…”
    Get full text
    Journal Article
  12. 12

    Real-Time Characterization of the Organic Composition and Size of Individual Diesel Engine Smoke Particles by Reilly, Peter T. A, Gieray, Rainer A, Whitten, William B, Ramsey, J. Michael

    Published in Environmental science & technology (15-09-1998)
    “…Real-time analysis of individual diesel engine exhaust particles was demonstrated using an ion trap mass spectrometer. Measurements were made on the nebulized…”
    Get full text
    Journal Article
  13. 13

    Real-Time Surface Analysis of Individual Airborne Environmental Particles by Lazar, Alexandru C, Reilly, Peter T. A, Whitten, William B, Ramsey, J. Michael

    Published in Environmental science & technology (15-11-1999)
    “…Typically, in real-time aerosol mass spectrometry (RTAMS), individual airborne particles are ablated and ionized with a single focused laser pulse. This…”
    Get full text
    Journal Article
  14. 14

    Direct Determination of Soil Surface-Bound Polycyclic Aromatic Hydrocarbons in Petroleum-Contaminated Soils by Real-Time Aerosol Mass Spectrometry by Rodgers, Ryan P, Lazar, Alexandru C, Reilly, Peter T. A, Whitten, William B, Ramsey, J. Michael

    Published in Analytical chemistry (Washington) (15-10-2000)
    “…Soil surface-bound polycyclic aromatic hydrocarbons (PAHs) were identified by use of Real-Time Aerosol Mass Spectrometry (RTAMS) in two NIST standard research…”
    Get full text
    Journal Article
  15. 15

    Tandem Mass Spectrometry of Uranium and Uranium Oxides in Airborne Particulates by Gieray, Rainer A, Reilly, Peter T. A, Yang, Mo, Whitten, William B, Ramsey, J. Michael

    Published in Analytical chemistry (Washington) (01-01-1998)
    “…A method for detection of uranium in airborne microparticles in real time has been developed. Positive identification of uranium is achieved by isolating UO2+…”
    Get full text
    Journal Article
  16. 16

    MALDI of Individual Biomolecule-Containing Airborne Particles in an Ion Trap Mass Spectrometer by Harris, William A, Reilly, Peter T. A, Whitten, William B

    Published in Analytical chemistry (Washington) (01-07-2005)
    “…Individual airborne biomolecule-containing particles were detected and characterized in near real-time by matrix-assisted laser desorption/ionization (MALDI)…”
    Get full text
    Journal Article
  17. 17

    Detecting Single Molecules in Liquids by Barnes, Michael D, Whitten, William B, Ramsay, J. Michael

    Published in Analytical chemistry (Washington) (01-07-1995)
    “…The trade-offs between sample throughput and sensitivity in single-molecule fluorescence detection are discussed, and examples of different detection schemes…”
    Get full text
    Journal Article
  18. 18
  19. 19

    Detection of single Rhodamine 6G molecules in levitated microdroplets by Barnes, Michael D, Ng, Kin C, Whitten, William B, Ramsey, J. Michael

    Published in Analytical chemistry (Washington) (01-09-1993)
    “…Single rhodamine 6G molecules in levitated glycerol microdroplets have been detected with signal-to-noise ratios of less than 40 using CW laser-induced…”
    Get full text
    Journal Article
  20. 20