Search Results - "Westwater, Ed"
-
1
Temperature and Humidity Profiling in the Arctic Using Ground-Based Millimeter-Wave Radiometry and 1DVAR
Published in IEEE transactions on geoscience and remote sensing (01-03-2010)“…A 1-D variational (1DVAR) retrieval technique has been developed for obtaining temperature and humidity profiles from observations of the Ground-Based Scanning…”
Get full text
Journal Article -
2
Columnar water vapor retrievals from multifilter rotating shadowband radiometer data
Published in Journal of Geophysical Research - Atmospheres (27-01-2009)“…The multifilter rotating shadowband radiometer (MFRSR) measures direct and diffuse irradiances in the visible and near‐infrared spectral range. In addition to…”
Get full text
Journal Article -
3
Analysis of integrated cloud liquid and precipitable water vapor retrievals from microwave radiometers during the Surface Heat Budget of the Arctic Ocean project
Published in Journal of Geophysical Research: Atmospheres (16-12-2001)“…We investigated a variety of factors that influence the determination of precipitable water vapor (V) and integrated cloud liquid (L) by dual‐channel microwave…”
Get full text
Journal Article -
4
Ground-Based Millimeter- and Submillimeter-Wave Observations of Low Vapor and Liquid Water Contents
Published in IEEE transactions on geoscience and remote sensing (01-07-2007)“…Ground-based observations at millimeter (mm) and submillimeter (submm) wavelengths were collected at the atmospheric radiation measurement program site at…”
Get full text
Journal Article Conference Proceeding -
5
Comparison of Ground-Based Millimeter-Wave Observations and Simulations in the Arctic Winter
Published in IEEE transactions on geoscience and remote sensing (01-09-2009)“…During the Radiative Heating in Underexplored Bands Campaign (RHUBC), held in February-March 2007, three millimeter-wave radiometers were operated at the…”
Get full text
Journal Article Conference Proceeding -
6
The Ground-Based Scanning Radiometer: A Powerful Tool for Study of the Arctic Atmosphere
Published in IEEE transactions on geoscience and remote sensing (01-09-2007)“…Measurements of water vapor and clouds in the polar regions are difficult, because conventional instruments show little sensitivity (~1.3 K/mm) to low amounts…”
Get full text
Journal Article -
7
Forward model studies of water vapor using scanning microwave radiometers, global positioning system, and radiosondes during the cloudiness intercomparison experiment
Published in IEEE transactions on geoscience and remote sensing (01-05-2005)“…Brightness temperatures computed from five absorption models and radiosonde observations were analyzed by comparing them with measurements from three microwave…”
Get full text
Journal Article Conference Proceeding -
8
Accuracy of ground-based microwave radiometer and balloon-borne measurements during the WVIOP2000 field experiment
Published in IEEE transactions on geoscience and remote sensing (01-11-2003)“…We discuss the performances of a set of four microwave water vapor radiometers operating in the 20-30-GHz band during a field experiment, with an emphasis on…”
Get full text
Journal Article -
9
An assessment of microwave absorption models and retrievals of cloud liquid water using clear-sky data
Published in Journal of Geophysical Research - Atmospheres (27-12-2003)“…Passive microwave radiometers have a long history in the remote sensing of atmospheric liquid and water vapor. Retrievals of these quantities are sensitive to…”
Get full text
Journal Article -
10
Correction to “Preface to special section: Remote Sensing of the Earth’s Environment by Microwave Radiometers and Radar (MARS)”
Published in Radio science (01-08-2003)Get full text
Journal Article -
11
Air and sea surface temperature measurements using a 60-GHz microwave rotating radiometer
Published in IEEE transactions on geoscience and remote sensing (01-01-1998)“…Data obtained from a single-channel scanning 5 mm radiometer on a research vessel were used for the study of sea surface temperature and lower-atmospheric…”
Get full text
Journal Article -
12
Thermodynamic Atmospheric Profiling During the 2010 Winter Olympics Using Ground-Based Microwave Radiometry
Published in IEEE transactions on geoscience and remote sensing (01-12-2011)“…Ground-based microwave radiometer profilers in the 20-60-GHz range operate continuously at numerous sites in different climate regions. Recent work suggests…”
Get full text
Journal Article -
13
Preface to special section: Remote Sensing of the Earth's Environment by Microwave Radiometers and Radar
Published in Radio science (01-06-2003)“…Dummy…”
Get full text
Journal Article -
14
Determination of cloud liquid water content using the SSM/I
Published in IEEE transactions on geoscience and remote sensing (01-09-1990)“…As part of a calibration/validation effort for the Special Sensor Microwave/Imager (SSM/I), coincident observations of SSM/I brightness temperatures and…”
Get full text
Journal Article -
15
Sea-air and boundary layer temperatures measured by a scanning 5-mm-wavelength radiometer: Recent results
Published in Radio science (01-03-1998)“…A scanning 5‐mm‐wavelength (60 GHz) radiometer was deployed during two recent experiments. The first was in September–October in 1995 when the Environmental…”
Get full text
Journal Article -
16
-
17
Analysis and improvement of tipping calibration for ground-based microwave radiometers
Published in IEEE transactions on geoscience and remote sensing (01-05-2000)“…The tipping-curve calibration method has been an important calibration technique for ground-based microwave radiometers that measure atmospheric emission at…”
Get full text
Journal Article -
18
Foreword to the Special Issue on the 10th Specialist Meeting on Microwave Radiometry and Remote Sensing of the Environment (MicroRad'08)
Published in IEEE transactions on geoscience and remote sensing (01-09-2009)“…The 14 papers in this special issue are organized into topical areas and applications, which are in the general order of the MicroRad technical sessions:…”
Get full text
Journal Article -
19
A Review of Ground-Based Remote Sensing of Temperature and Moisture by Passive Microwave Radiometers
Published in IEEE transactions on geoscience and remote sensing (01-05-1986)“…Remote sounding of atmospheric variables by groundbased microwave radiometers has proved to be useful for several applications. These radiometers are used to…”
Get full text
Journal Article -
20
High Temporal-Resolution Infrared-Radiometric Observations of the Atmospheric Boundary Layer
Published in IEEE transactions on geoscience and remote sensing (01-03-1986)“…An experiment designed to study the relationship of radiometric fluctuations to those of temperature and associated variables in the atmospheric boundary layer…”
Get full text
Journal Article