Search Results - "Walledge, R.J."
-
1
One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays
Published in IEEE transactions on nuclear science (01-06-2002)“…High-resolution three-dimensional (3-D) positron emission tomography (PET) scanners with high count rate performance, such as the quad-high density avalanche…”
Get full text
Journal Article -
2
Inter-frame filtering for list-mode EM reconstruction in high-resolution 4-D PET
Published in IEEE transactions on nuclear science (01-06-2004)“…Dynamic (4-D) PET imaging is a routinely used technique applied in clinical studies, and is now also finding application for high resolution animal PET…”
Get full text
Journal Article -
3
Regularized one-pass list-mode EM algorithm for high resolution 3D PET image reconstruction into large arrays
Published in 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) (01-01-2002)“…High resolution 3D PET scanners with high count rate performance, such as the quad-HIDAC, place new demands on image reconstruction algorithms due to the large…”
Get full text
Conference Proceeding -
4
Interframe filtering for list-mode EM reconstruction in high-resolution 4D PET
Published in 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) (2003)“…Dynamic (4D) PET imaging is a routinely used technique applied in clinical studies, and is now also finding application for high resolution animal PET systems…”
Get full text
Conference Proceeding -
5
Scatter modeling for 3-d PET list-mode EM reconstruction
Published in 2002 IEEE Nuclear Science Symposium Conference Record (2002)“…It is widely recognized that scattered radiation is a significant issue in 3-D positron emission tomography (PET). This work proposes a method to address the…”
Get full text
Conference Proceeding -
6
4D PET with the quad-HIDAC: development of dynamic list-mode EM image reconstruction
Published in 2002 IEEE Nuclear Science Symposium Conference Record (2002)“…The sub-millimeter imaging capability of the quad-HIDAC , combined with its good count rate performance, offers great potential for biomedical research. This…”
Get full text
Conference Proceeding -
7
Quad-HIDAC PET: comparison of four image reconstruction techniques for high resolution imaging
Published in 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) (2001)“…The quad-HIDAC PET scanner offers unparalleled high resolution PET imaging capability (<1 mm), combined with notable count rate performance (400 kcps) and…”
Get full text
Conference Proceeding