Search Results - "Wagner, Dietmar"

Refine Results
  1. 1
  2. 2

    ECE Diagnostic for the initial Operation of Wendelstein 7-X by Hirsch, Matthias, Höfel, Udo, Oosterbeek, Johan Willem, Chaudhary, Neha, Geiger, Joachim, Hartfuss, Hans-Jürgen, Kasparek, Walter, Marushchenko, Nikolai, van Milligen, Boudewijn, Plaum, Burkhard, Stange, Torsten, Svensson, Jakob, Tsuchiya, Hayato, Wagner, Dietmar, McWeir, Gavin, Wolf, Robert

    Published in EPJ Web of Conferences (01-01-2019)
    “…The ECE diagnostic at W7-X in its standard mode of operation measures in X2 mode polarization with a 32 channel radiometer in the frequency band around 140 GHz…”
    Get full text
    Journal Article Conference Proceeding
  3. 3

    Experiments with reduced single pass absorption at ASDEX Upgrade – instrumentation and applications by Schubert, Martin, Stober, Joerg, Herrmann, Albrecht, Grigore, Eduard, Kasparek, Walter, Lechte, Carsten, Monaco, Francesco, Petzold, Bernhard, Plaum, Burkhard, Poli, Emanuele, Ruset, Cristian, Vorbrugg, Stefan, Wagner, Dietmar

    Published in EPJ Web of conferences (2023)
    “…Reflecting gratings have been installed in the vacuum vessel of ASDEX Upgrade for all beamlines of the electron cyclotron resonance heating system. Potentially…”
    Get full text
    Journal Article
  4. 4

    Simulation of Polarising and Reflector Gratings for High Power mm Waves by Lechte, Carsten, Kasparek, Walter, Plaum, Burkhard, Leuterer, Fritz, Schubert, Martin, Stober, Jörg, Wagner, Dietmar

    Published in EPJ Web of conferences (01-01-2019)
    “…High power mm waves for fusion plasma heating need to be elliptically polarised to ensure good absorption in the plasma. In some scenarios, electron cyclotron…”
    Get full text
    Journal Article Conference Proceeding
  5. 5

    Studies towards an upgraded 1.5 MW gyrotron for W7-X by Avramidis, Konstantinos A., Ruess, Tobias, Mentgen, Felix, Jin, Jianbo, Wagner, Dietmar, Gantenbein, Gerd, Illy, Stefan, Ioannidis, C., Laqua, Heinrich P., Pagonakis, Ioannis Gr, Rzesnicki, Tomasz, Thumm, Manfred, Wolf, Robert C., Jelonnek, John

    Published in EPJ Web of Conferences (01-01-2019)
    “…Studies towards a 1.5 MW, 140 GHz CW gyrotron, with the capability of MW-class operation also at 175 GHz, are ongoing at Karlsruhe Institute of Technology in…”
    Get full text
    Journal Article Conference Proceeding
  6. 6

    Beam tracing study for design and operation of two-pass electron cyclotron heating at ASDEX Upgrade by Schubert, Martin, Plaum, Burkhard, Stober, Jörg, Herrmann, Albrecht, Kasparek, Walter, Lechte, Carsten, Leuterer, Fritz, Monaco, Francesco, Petzold, Bernhard, Poli, Emanuele, Vorbrugg, Stefan, Wagner, Dietmar

    Published in EPJ Web of conferences (01-01-2019)
    “…The electron cyclotron resonance heating system at ASDEX Upgrade (AUG) is currently being extended to eight similar Gyrotrons in total. Each Gyrotron operates…”
    Get full text
    Journal Article Conference Proceeding
  7. 7

    Improvement of the Output Mode Purity of a Complex-Cavity Resonator for a Frequency-Tunable Sub-THz Gyrotron by Wagner, Dietmar, Thumm, Manfred

    Published in IEEE transactions on electron devices (01-10-2021)
    “…One way to improve the mode selection in terahertz gyrotrons is the use of stepped cavity resonators that satisfy the resonance condition for two modes with…”
    Get full text
    Journal Article
  8. 8

    Highly Efficient Quasi-Optical Mode Converter for a Multifrequency High-Power Gyrotron by Prinz, O., Arnold, A., Gantenbein, G., Ying-hui Liu, Thumm, M., Wagner, D.

    Published in IEEE transactions on electron devices (01-05-2009)
    “…A highly efficient quasi-optical mode converter with a bandwidth of 38 GHz has been designed and tested. The mode converter combines low-diffraction losses and…”
    Get full text
    Journal Article
  9. 9

    Primary angiosarcoma of the ovary with prominent fibrosis of the ovarian stroma. Case report of an 81-year old patient by Bösmüller, Hans, Gruber, Christine, Haitchi-Petnehazy, Sophie, Wagner, Dietmar, Webersinke, Gerald, Hauptmann, Steffen

    Published in Diagnostic pathology (14-07-2011)
    “…Primary angiosarcoma of the ovary (AS) is a rare entity with only 31 reported cases. The majority are pure angiosarcomas, the remainder are associated either…”
    Get full text
    Journal Article
  10. 10

    Extension of electron cyclotron heating at ASDEX Upgrade with respect to high density operation by Schubert, Martin, Stober, Jörg, Herrmann, Albrecht, Kasparek, Walter, Leuterer, Fritz, Monaco, Francesco, Petzold, Bernhard, Plaum, Burkhard, Vorbrugg, Stefan, Wagner, Dietmar, Zohm, Hartmut

    Published in EPJ Web of conferences (01-01-2017)
    “…The ASDEX Upgrade electron cyclotron resonance heating operates at 105 GHz and 140 GHz with flexible launching geometry and polarization. In 2016 four…”
    Get full text
    Journal Article Conference Proceeding
  11. 11

    Bragg Reflection Band Stop Filter for ECE on Wega by Wagner, Dietmar, Kasparek, Walter, Leuterer, Fritz, Monaco, Francesco, Münich, Max, Schütz, Harald, Stange, Torsten, Stober, Jörg, Thumm, Manfred

    “…Notch filters are required to protect sensitive millimeter wave diagnostics in fusion experiments from gyrotron stray radiation in the plasma vessel. A new…”
    Get full text
    Journal Article
  12. 12

    Machine safety issues with respect to the extension of ECRH systems at ASDEX Upgrade by Schuberta, Martin, Herrmann, Albrecht, Monaco, Francesco, Rohde, Volker, Schütz, Harald, Stober, Jörg, Vierle, Thomas, Vorbrugg, Stefan, Wagner, Dietmar, Zasche, Dieter, Zehetbauer, Thomas, Zeidner, Wolfgang

    Published in EPJ Web of Conferences (01-01-2015)
    “…The beam intensity of electron cyclotron resonance heating at ASDEX Upgrade has the potential to seriously damage in-vessel components, whenever not fully…”
    Get full text
    Journal Article Conference Proceeding
  13. 13
  14. 14

    Single- and Two-Frequency Sub-THz Waveguide Notch Filters With Rejection Frequencies Within and Beyond the Passband by Wagner, Dietmar, Kasparek, Walter, Leuterer, Fritz, Monaco, Francesco, Plaum, Burkhard, Ruess, Tobias, Schutz, Harald, Stober, Jorg, Thumm, Manfred

    “…Notch filters are a key component in millimeter-wave plasma diagnostics systems for magnetically confined fusion plasmas. They are required to protect…”
    Get full text
    Journal Article
  15. 15

    In-situ Low Power Tests of the ASDEX Upgrade ECRH Transmission Lines by Wagner, Dietmar, Leuterer, Fritz, Monaco, Francesco, Schütz, Harald, Stober, Jörg, Thumm, Manfred

    Published in EPJ Web of conferences (2024)
    “…An Electron Cyclotron Resonance Heating (ECRH) system employing 8 gyrotrons is in routine operation at the ASDEX Upgrade tokamak at IPP Garching. The gyrotrons…”
    Get full text
    Journal Article Conference Proceeding
  16. 16

    First Operation of a Step-Frequency Tunable 1-MW Gyrotron With a Diamond Brewster Angle Output Window by Gantenbein, Gerd, Samartsev, Andrey, Aiello, Gaetano, Dammertz, Guenter, Jelonnek, John, Losert, Markus, Schlaich, Andreas, Scherer, Theo Andreas, Strauss, Dirk, Thumm, Manfred, Wagner, Dietmar

    Published in IEEE transactions on electron devices (01-06-2014)
    “…Experimental results using a step-frequency tunable D-band gyrotron are reported. The short pulse (~3 ms) gyrotron is equipped with an elliptically brazed…”
    Get full text
    Journal Article
  17. 17

    High Purity Mode CW Gyrotron Covering the Subterahertz to Terahertz Range Using a 20 T Superconducting Magnet by Idehara, Toshitaka, Ogawa, Isamu, Wagner, Dietmar, Thumm, Manfred, Kosuga, Kosuke, Sabchevski, Svilen Petrov

    Published in IEEE transactions on electron devices (01-08-2018)
    “…In this paper, we present the current status and both the ongoing investigation and the continuous improvements to the operational performance of a unique…”
    Get full text
    Journal Article
  18. 18
  19. 19
  20. 20

    Stepped Sub-THz Gyrotron Cavity with Improved Output Mode Purity by Wagner, Dietmar, Thumm, Manfred

    “…Stepped cavity resonators are used in terahertz gyrotrons for better mode selection. They can satisfy the resonance condition for two modes with different…”
    Get full text
    Conference Proceeding