Three, Four and Seven Parameters Sine-fitting Algorithms Applied in the Electric Power Calibrations

Algorithms written in VBA with three, four and seven parameters sine-fitting are presented. They estimate values of frequency, amplitude, phase, offset, and RMS noise of sinusoidal waves. 4PSF algorithm applied on voltage and current signals from power source give two different frequencies. Applicat...

Full description

Saved in:
Bibliographic Details
Published in:EUROCON 2005 - The International Conference on "Computer as a Tool" Vol. 2; pp. 1148 - 1150
Main Authors: Vucijak, N.M., Radojevic, N.M.
Format: Conference Proceeding
Language:English
Published: IEEE 2005
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Algorithms written in VBA with three, four and seven parameters sine-fitting are presented. They estimate values of frequency, amplitude, phase, offset, and RMS noise of sinusoidal waves. 4PSF algorithm applied on voltage and current signals from power source give two different frequencies. Application of 7PSF algorithm gives same frequency for both signals and about two times lower uncertainties for phase difference calculations than 4PSF algorithm. Abbreviations: 3PSF - three parameters sine-fitting; 4PSF - four parameters sine-fitting; 7PSF - seven parameters sine-fitting; DVM - digital voltmeter; DUT - device under test; and VBA - Visual Basic for Applications
ISBN:9781424400492
142440049X
DOI:10.1109/EURCON.2005.1630156